3. Connect the wire coloured brown to the
terminal either marked with the ā€œLā€œ or
coloured red.
4. Check that no cut, or stray strands of
wire is present and the cord clamp (E)
is secure over the outer sheath.
Make sure the electricity supply voltage
is the same as that indicated on the
appliance rating plate.
5. Switch on the appliance.
The appliance is supplied with a 13 amp
fuse (B). In the event of having to change
the fuse in the plug supplied, a 13 amp
ASTA approved (BS 1362) fuse must be
used.
WARNING!
A cut off plug inserted into a 13 amp
socket is a serious safety (shock)
hazard. Ensure that it is disposed of
safely.
Ventilation requirements
The airflow behind the appliance must be
sufficient.
5 cm
min.
200 cm
2
min.
200 cm
2
CAUTION!
Refer to the assembly instructions for
the installation.