SPLIT TYPE ROOM AIR CONDITIONER OWNER'S MANUAL utions carefully and thoroughly before From the Electrolux Group.
Contents Welcome to the world of simple handling and no worries. Thank you for choosing Frigidaire. This manual contains all of the information required to guarantee your safety and the appropriate use of your air conditioner. Please read all of the instructions this manual for future reference. before using the air conditioner Safety precaution ................................................................................. 03 Installation .............................................................
Safety precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. 1. Connect with the power properly. Otherwise, it may cause electric shock or fire due to excess heat generation. 2. Do not modify power cord length or share the outlet with other appliances.
19.Donotcleantheairconditioner withwater. Watermayentertheunitand degrade theinsulation. Itmaycauseanelectricshock. 20.Ventilate theroomwellwhenused together witha stove,etc. Anoxygenshortage mayoccur. 21.Whentheunitistobecleaned, switchoff,andturnoffthecircuit breaker. Donotcleanunitwhenpoweris onasitmaycausefireand electricshock,itmaycausean injury. 22.Donotputa petorhouseplant whereitwillbeexposed todirect airflow. Thiscouldinjurethepetorplant. 23.Donotuseforspecialpurposes.
Installation Choosing Precautions the installation Outdoor site 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. for installation Installation at the following sites may cause problems. If you must inevitably install the unit at one of these sites, please consult your local distributor beforehand: 1. Site with machine oil. 2. Sites with a high concentration 3.
Part list more than 15cm_ Rndoorunit More than 12cm Air Filter <_ More than 60cm More than 30cm \ ......... Indoor A J B C More than 200cm Outdoor Unit unit O The indoor unit should be installed The pipe needs the minimun avoid vibration or noise. Outdoor unit More than 60cm no lower than 2,3 m. of 4 or 5 meters, this distance will contribute to Two of the three direction above (A, B, C) should be not be blocker. The copper pipe can be isolated independent.
Indoor unit Installation installation plate drilling and assembly Connective pipe and drainage installation Drainage 150mm Indoor unit outline Installationplate f"..... or more to wall i i ' _ _ "................... to wall 2. When connection Fixing the installation 16000 extension Do not 16000 Btu/h) plate: 1. Fit the installation plate horizontally on structural parts of the walt with spaces around the installation plate. 2.
Outdoor 3. Piping can easily be made by lifting the indoor unit with a cushion material between the indoor unit and the wall. Get it out after finish piping. from rear of the indoor unit is gathered in Pond Box and is piped out of room. Do not put anything else in the box. 2. Determine the air outlet direction where the discharged blocked. air is not 3.
Refrigerant Settlement of outdoor unitAnchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount. piping connection Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work sing the following procedure: Air 1. '_ Pipe Cut the pipes and the cable. All outlet A) Use the piping kit accessory pipes purchased locally. or B) Measure the distance between the indoor and the outdoor unit.
Electrical Electric 4. Flaring work. A) Firmly hold copper pipe in a die in thedimension shown in the table below. B'a_,__ Copper ! Handle Yoke Clamp handle Tightening 2. Sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque wrench as shown. unit safety Flare nut regulations for the initial installation 1. If there is serious safety problem about the power supply, the technicians should refuse to install 5.
Connect the cable to the indoor unit Connect 1. Indoor/Outdoor connection cable should be H07RN-F type. 2. Remove the screw, then remove the window cover. 3. Connect cables according marks to terminals. 1. Remove the electric parts cover from the outdoor unit. 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. 3.
Caution: Air purging with vacuum pump After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation.
Electricel Using the vacuum pump sefety Check the electrical safety before finalizing the installation. 1. The insulation 1. Completely tighten the flare nuts, A, B, C, D, connect the manifold valve charge hose to a charge port of the low-pressure valve on the gas pipe side. 2. Connect the charge hose connection to the vacuum pump. 7. Remove the charge hose from the Low pressure charge hose. 8. Fully open the packed B and A. valve stems 9. Securely tighten the cap of the packed valve. 3.
Test running Preparing Perform test running after completing gas leak and electrical The test running time should last more than 30 minutes. 1. Open the panel and lift the panel up to an angle which remains fixed. Do not lift the panel any further when it stops with a click sound. 2. Press the manual control button twice until the operating indicator lights up, the unit wilt operate on Forced Cool mode. safety check. 3. Check if all the functions works welt during test running.
Product description Display panel (indoor unit) Front panel frame Front panel Air filter (inside the front panel) Horizontal airflow grille Vertical airflow infrared signal receptor Auto: When you set the air conditioner to AUTO mode, the louver indoor temperature sensor (inside the frontal panel) Display panel infrared signal indicator starts flashing.
Remote control Performance functions features / Install Function controller uses two alkaline dry batteries (R03/LR03X2). 1. To install batteries, slide back the cover of the battery compartment and install the batteries according to the directions (+and-) show on the remote controller. in 24 hours. 3. Indoor Setting Temperature 17 C-30 C. / replace batteries i!iii i iiii ' ii i,i The remote 1. Operating Mode: AUTO, COOL, DRY, HEAT(Cooling only model without) and FAN. 2. Timer Setting ....
Remote control operations TEMP Button V : Push this button to decrease the indoor temperature setting. .MODE: Each time the button is pressed, the operation mode is shifted in the direction of the arrow: AUTO _ COLL I_ DRY I_ HEAT I_ FAN t * Note:COOL feature. only model has no HEAT Display: SWING: Push this switch button to change the louver angle.
How Display: cooling model Display: TURBO: Push this button on COOL mode, the air conditioner goes into powerful cooling operation. Push again to cancel the TURBO function (for only cooling/heating model ). LOCK iNDiCATOR: LOCK display is displayed by pushing the LOCK button. Push the LOCK button to clear display. OPERATION MODE indicator: When press the MODE button, it shows the current operating mode: AUTO, COOL, DRY, HEAT (only cooling/heating model) or FAN mode.
ECONOMIC mode PresstheECONOMIC keytoactive theECONOMIC mode.Pressthis buttonagaintodeactivate it. In the cold and dry modes: - The indoor unit fan can be set on low speed. - After one hour of operation, the adjusted temperature will increase 1°C (34°F). After one hour, the temperature will increase another 1°C (34°F). The unit will continue to operate 2°C (36°F) above the adjusted temperature.
Adjusting DRY Operation The dry mode will automatically select the drying operation based on the difference between the set temperature and the actual room temperature.. The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only. 1. Push the MODE button to select DRY. 2. Push the TEMP button to set the desired temperature from 21C to 28C. 3.
Manual horizontal louveris ina specific position, movetheleveratleft(or right,depending onmodel). ,,Adjusttheairflowdirection properly otherwise, it mightcausediscomfort or causeunevenroom temperatures.,, Adjustthehorizontal louverusingtheremotecontroller.,, Adjusttheverticallouvermanually. Adjusting the Vertical Air Flow Direction (up=down)The air conditioner automatically adjusts the vertical air flow direction in accordance with the operating mode.
Cleaning Cleaning and maintenance the air filter A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks. Cleaning the indoor unit and remote controller 1. Use a dry cloth to wipe the indoor unit and remote controller. 1. Lift the indoor unit panel up to an angle until it stops with a clicking sound. .2. A cloth dampened with cold water may be used on the indoor unit if it is very dirty. 2.
Operation tips Dust is blown The following Protection events may occur during normal operation: The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. 1. When heating has just starting. 2. Defrosting.
Troubleshooting tips Environmental Malfunctions and solutions Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. advices The packaging material used is recyclable; we recommend that you separate plastic, paper and cardboard and give them to recycling companies.
Technicel inforrnations Cooling only type Cooling only type Cycle Cooling power (Btu/h) Rated Voltage (V) Coot Cool Cool 9000 12000 18000 24000 220-230- 220-230- Cooling power (Btu/h) 6O 6O 6O Indoor unit high (mm) 275 275 275 3!3 Indoor unit width (ram) 79O 790 928 1030 190 198 221 Indoor unit depth (ram) 190 8,5 9 10 14,5 540 695 (Hz) Indoor unit net weight (kg) unit high (mm) 43O 535 685 7OO 78O 845 Outoer unit width (mm) Outdoor 260 235 250 335 24 27 3
Cooling only type Cool Cycle Cooling power (Btu/h) Rated Voltage (V) Frequency (Hz) Cool Cool Cool 9000 12000 18000 24000 220-230~ 220-230~ 220-230~ 220-230~ 6O 6O 6O 6O Indoor unit high (mm) 275 275 275 3!3 Indoor unit width (mm) 790 790 928 1030 Indoor unit depth (mm) 190 190 198 221 Indoor unit net weight (kg) 8,5 9 10 14,5 Outdoor unit high (mm) 43O 535 54O 695 Outoor unit width (mm) 685 7OO 78O 845 Outdoor unit depth (mm) 26O 235 25O 335 24 27 34