Product information

CC
CAPACITOR
(SINGLE PHASE)
FIELD SUPPLY
L1
GRD
L2
GROUNDING
SCREW
C
S
T1
T2
L1 L2
CONTACTOR
R
COMPRESSOR
Y2 IN
FAN2CCH2CCH1
W2 IN
Y1 IN CR
HOT1
HOT2
(24V COM)
OUTDOOR
TEMP
Y1 OUT
RV1
O
LP1LP2HP1HP2
CC
DEFROST CONTROL
BOARD
YELLOW/
YELLOW BLACK
BLACK/
BLACK WHITE
COIL#1
TEMP
RV2
CCH
RVS
HPS
COIL SENSOR
HGBP
AMB SENSOR
Y R O C W2 E
THERMOSTAT
FAN1
W2 OUT
Y2 OUT
BLACK
ODT
(OPTIONAL OUTDOOR
THERMOSTAT)
BLACK
HC
OUTDOOR
FAN MOTOR
Y1
C
Y2
ECM
L2
L1
RED/RED BLACK
BROWN
BLUE
YELLOW
LPS
Split System Heat Pump (Outdoor Section) - Medium Speed ECM Motor Single Phase
WIRING DIAGRAM
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150 volts to ground
4. For replacement wires use conductors suitable for 105˚ C.
5. For ampacities and overcurrent protection, see unit rating plate.
6. Connect to 24 vac/40va/class 2 circuit. See furnace/air handler
installation instructions for control circuit and optional
relay/transformer kits.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 volt a la terre.
10252940
(NEW)
01/19
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
AMB SENSOR - Ambient Sensor
CC - Contactor Coil
CCH - Crankcase Heater
HPS - High Pressure Switch
HGBP - Hot Gas By Pass Valve
RVS - Reversing Valve Solenoid
* HARD START KIT (OPTIONAL)
LPS - Low Pressure Switch
START
CAPACITOR*
START RELAY*
5
2
1
YELLOW
BLACK
BLACK
YELLOW
BLACK
BLACK
BLACK

Summary of content (1 pages)