PROFESSIONAL SERIES Models PL30WC51EC PL36WC51EC PL42WC51EC ENGLISH. ................................... .2 F.AN_A_S ...............................
_, _ INTENDED FOR DOMESTIC COOKING ONLY _, WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR iNJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
OPERATION BLOWER Controls LIGHT SWITCH The hood is operated using the (4) push-buttons edge of the hood. MEDIUM PILOT SPEED LAMP located at eye-level, on the front BLOWER ON-LOW The light switch turns the halogen lamps on and off. / OFF The blower on-low / off switch turns the blower on to its lowest running speed. The blower must be turned on using this switch. Turn the blower off by pressing this switch a second time. SWITCH The blower medium speed switch changes the blower speed to medium.
PREPARE THE HOOD Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag containing: 1 - Mounting Bracket 1 - Discharge Collar 1 - Flue Mounting Bracket 8 - Mounting Screws (4,8 x 38mm Pan Head) 4 - Mounting Screws (3,9 x 9,5mm Pan Head) 2 - Mounting Screws (3.9 x 6ram Flat Head) 8 - Drywall Anchors 1 - Installation Instructions DISCHARGE COLLAR MOUNTING BRACKET SCREWS (3.9 X 9.5ram Pan Head) 4 MOUNTING 2 MOUNTING BRACKET SCREWS (3.
INSTALL [ THE DUCTWORK 1 (DUCTED HOODS ONL Y) ,_ ROOFCAP \ CAUTION: To reduce the risk of fire, use only metal ductwork. 1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions wilt reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a roof or wall cap.
INSTALL FLUE MOUNTING (DUCTED AND NON-DUCTED BRACKET HOODS) 1. Assemble the flue mounting bracket, adjusting outside width as shown. 2. Carefully See Figure 7. center the mounting bracket directly over the range hood location. 3. Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors (Fig. 8). Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood. FLUE MOUNTING BRACKET DRYWALL ANCHORS 3.
PREPARE THE HOOD (NON - DUCTED HOODS ONLY) Note: The following materials must be purchased separately ° Non - Ducted Recirculation Kit, Model DFKTWC51EC. for non-ducted recirculation installations. ° 5" diameter metal duct. 1. Discard discharge collar and damper supplied with the hood. Install the 5" to 6" adapter supplied with the Non-Ducted Recircutation Kit. Fig. 10. 2. Secure the plenum to the flue mounting bracket with (2) 3.
INSTALL THE HOOD, cont'd 8. Carefully place the decorative flue on the hood. Fig. 13. - On ducted installation in rooms with 8-foot ceilings, the air vents are concealed. Install the flue with the air vents down. - On non-ducted installations in rooms with 8-foot ceilings, the air vents are exposed. Install the flue with the air vents up. - On ducted and non-ducted installations in rooms with 9-foot ceilings, the vents are exposed. Install the flue with air vents up.
SERVICE PARTS - LISTE PIECES DE RECHANGE MODELS PL30WC51EC - PL36WC51EC - PL42WC51EC KEY No.
SERVICE PARTS MODELS PL30WC51EC - LISTE PIECES - PL36WC51EC DE RECHANGE - PL42WC51EC 60 86 67 477 152 119 407 195 118 / \ \ \ \ \ \ \, \ \ \ 113 \ \ .[_ \ 230 228 234 @ 49 48 53 45 9 16