How to Guide

Stainless Chimney Wall-Mount Hood
RH36WC55G S
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxappliances.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
RH36WC55G 02/08 © 2008 Electrolux Major Appliances, NA Printed in the U.S.A.
36" Stainless Chimney Wall-Mount Hood Specifications
Product Weight – 39 Lbs.
Wall-Mount Installation
Ventilation is convertible to be either ducted outside, or recirculated
inside requiring no ducting.
Sones Rating – 9.0
Voltage Rating –120V/60 Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 0.475kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @120 Volts = 3.84 Amps
Always consult local and/or national electric codes. Check local
building codes for installation requirements, as they may vary per locale.
Minimum installation height allowed from bottom of hood to cooking
surface is 24"- 30" for electric and 30" for gas. (NOT more than 36"
recommended.)
To prepare mounting surface, adequate structure and support must be
provided, capable of supporting 100 lbs.
Ducted Option Specifications
For outside ventilation only.
Exhaust Duct Required – 8" round
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
Use metallic flex ducting only to connect rigid duct directly to transitions
(if allowed by code).
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
Cold weather installations should have additional backdraft damper
installed.
Refer to web for detailed duct preparation installation instructions.
Ductless (Recirculated) Option Specifications
If ducting to outside is not an option, vent hood can be converted to
ductless with use of optional Duct-Free Kit (RHDFW60GS).
Refer to web for detailed convertible ventilation installation instructions.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
Duct-Free Kit – (RHDFW60GS).
52" Flue Extension – (RHXWC55GS).
Controls
Top
Wiring boxAir outlet - 7
7
/8" diam.
4
9
/16"
24
5
/8"
min.
42
9
/16"
max.
5"
19
11
/16"
35
7
/8"
13
3
/16"
10
11
/16"
Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.
24"
( min.
height
with one