Primo Data Sheet

M,06,0229,EN-US USA REV. 04/09/18
/ Perfect Welding / Solar Energy / Perfect Charging
v08 Aug 2017 EN
Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com
THREE BUSINESS UNITS, ONE GOAL: TO SET THE STANDARD THROUGH TECHNOLOGICAL ADVANCEMENT.
What began in 1945 as a one-man operation now sets technological standards in the fields of welding technology, photovoltaics and battery charging. Today, the
company has around 3,800 employees worldwide and 1,242 patents for product development show the innovative spirit within the company. Sustainable
development means for us to implement environmentally relevant and social aspects equally with economic factors. Our goal has remained constant throughout:
to be the innovation leader.
Fronius USA LLC
6797 Fronius Drive
Portage, IN 46368 USA
pv-support-usa@fronius.com
www.fronius-usa.com
1
inverter rated for up to 1000 V open-circuit. Nominal, Operating, and MPP voltages based on 600 V system design. Actual DC system voltage is dependent on PV string-sizing, not inverter input capacity.
INPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1
Recommended PV power (kWp) 3.0 - 6.0 kW 4.0 - 7.8 kW 4.8 - 9.3 kW 6.1 - 11.7 kW 6.6 - 12.7 kW
Max. usable input current (MPPT 1/MPPT 2) 18 A / 18 A
Max. usable input current (MPPT 1+MPPT 2) 36 A
Max. array short circuit current (1.5* lmax) (MPPT1/MPPT2) 27 A / 27 A
Nominal input voltage 410 V 420 V 420 V 420V 420 V
Operating voltage range 80 V - 600 V
DC startup voltage 80 V
MPP Voltage Range 200-480 V 200-400 V 240-480 V 250-480 V 270-480 V
Max. input voltage 600 V (1000 V optional
1
)
Admissible conductor size DC
$:*$:*FRSSHUVROLGVWUDQGHGʉQHVWUDQGHG$:*FRSSHURU$:*DOXPLQLXPIRURYHUFXUUHQWSURWHFWLYHGHYLFHV
up to 60A, from 61 to 100A minimum AWG 8 for copper or AWG 6 aluminium has to be used) , AWG 6 - AWG 2 copper(solid /
stranded) MultiContactWiringable with AWG 12
Number of MPPT 2
OUTPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1
Max. output power 208 V/240 V 3800 VA/3800 VA 5000 VA/5000 VA 6000 VA/6000 VA 7600 VA/7600 VA 7900 VA/8200 VA
2XWSXWFRQʉJXUDWLRQ 208/240 V
Frequency range (adjustable) 45.0 - 55.0 Hz / 50 - 66 Hz
Operating frequency range default for CAL setups --/ 58.5 - 60.5 Hz
Operating frequency range default for HI setups --/ 57.0 - 63.0 Hz
Nominal operating frequency 60 Hz
Admissable conductor size AC AWG 14 - AWG 6
Total harmonic distortion < 5.0 %
Power factor range 0.85-1 ind./cap
Max. continuous output current 208 V 18.3 A 24.0 A 28.8 A 36.5 A 38.0 A
240 V 15.8 A 20.8 A 25.0 A 31.7 A 34.2 A
OCPD/AC breaker size 208V 25 A 30 A 40 A 50 A 50 A
240 V 20 A 30 A 35 A 40 A 45 A
0D[(ʋFLHQF\ 96.7 % 96.9 % 96.9 % 96.9 % 97.0 %
&(&(ʋFLHQF\ 95.0 % 95.5 % 96.0 % 96.0 % 96.5 %
INPUT DATA PRIMO 10.0-1 PRIMO 11.4-1 PRIMO 12.5-1 PRIMO 15.0-1
Recommended PV power (kWp) 8.0 - 12.0 kW 9.1 - 13.7 kW 10.0 - 15.0 kW 12.0 - 18.0 kW
Max. usable input current (MPPT 1/MPPT 2) 33.0 / 18.0 A
Max. usable input current (MPPT 1+MPPT 2) 51 A
Max. array short circuit current (1.5 * Imax) 49.5 A/ 27.0
Nominal input voltage 655 V 660 V 665 V 680 V
Operating voltage range 80 V - 1,000 V
DC startup voltage 80 V
MPP Voltage Range 220-800 V 240-800 V 260-800 V 320-800 V
Max. input voltage 1000 V
Admissible conductor size DC
AWG 14 - AWG 6 copper direct, AWG 6 aluminum direct (AWG 10 copper or AWG 8 aluminium for overcurrent protective devices
up to 60A, from 61 to 100A minimum AWG 8 for copper or AWG 6 aluminium has to be used), AWG 4 - AWG 2 copper or alu-
minum with optional input combiner
Number of MPPT 2
Integrated DC string fuse holders 4- and 4+ for MPPT 1 / no fusing required on MPPT 2
OUTPUT DATA PRIMO 10.0-1 PRIMO 11.4-1 PRIMO 12.5-1 PRIMO 15.0-1
Max. output power 208 V/240 V 9995 VA/9995 VA 11400 VA/11400 VA 12500 VA/12500 VA 13750 VA/15000 VA
2XWSXWFRQʉJXUDWLRQ 1~NPE 208/240 V
Frequency range (adjustable) 45-55 Hz / 50-66 Hz
Operating frequency range default for CAL setups --/ 58.5 - 60.5 Hz
Operating frequency range default for HI setups --/ 57.0 - 63.0 Hz
Nominal operating frequency 60 Hz
Admissible conductor size AC
$:*$:*FRSSHUVROLGVWUDQGHGʉQHVWUDQGHG$:*FRSSHURU$:*DOXPLQXPIRURYHUFXUUHQWSURWHFWLYHGHYLFHVXS
to 60 A, from 61 to 100A minimum AWG 6 aluminum has to be used), AWG 6-AWG 2 copper (solid/stranded) Multi Contact Wiring
able with AWG 12
Total harmonic distortion < 2.5 %
Power factor range 0-1 ind./cap.
Max. continuous output current 208 V 48.1 A 54.8 A 60.1 A 66.1 A
240 V 41.6 A 47.5 A 52.1 A 62.5 A
OCPD/AC breaker size 208 V 70 A 70 A 80 A 90 A
240 V 60 A 60 A 70 A 80 A
0D[(ʋFLHQF\ 96.7 %
&(&(ʋFLHQF\999 96.0 % / 96.5 % 96.5 % / 97.0 %
TECHNICAL DATA FRONIUS PRIMO