Primo Operating Instructions

10
Selecting a Loca-
tion – General In-
formation for
Fronius Primo
10.0–15.0
Please note the following criteria when choosing a location for the inverter:
Only install on a solid surface
Max. ambient temperatures:
-40°F to +140°F
(-40°C to +60°C)
Relative humidity:
0–100%
The air flow direction within the
inverter is from right to top (cold
air intake on the right, hot air out-
flow at the top).
When installing the inverter in a switch cabinet or similar closed environment, it is neces-
sary to make sure that the hot air that develops will be dissipated by forced-air ventilation.
If you wish to install the inverter on the outer walls of a cattle shed, it is important to main-
tain a minimum clearance of 6 ft. 7 in. (2 m) between all sides of the inverter and air vents
and other openings.
The place of installation should not be exposed to ammonia, corrosive gases, salts, or ac-
ids.
4 in.
100 mm
4 in.
100 mm
8 in.
200 mm
-40 °F - +140 °F
-40 °C - +60 °C
0 - 100 %