Product Specification
M,06,0229,EN-US USA REV. 08/05/2022
/ Perfect Welding / Solar Energy / Perfect Charging
Text and images correspond to the current state of technology at the time of printing. Subject to modifications.
All information is without guarantee in spite of careful editing - liability excluded. Copyright © 2011 Fronius™. All rights reserved.
Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com
THREE BUSINESS UNITS, ONE GOAL: TO SET THE STANDARD THROUGH TECHNOLOGICAL ADVANCEMENT.
What began in 1945 as a one-man operation now sets technological standards in the fields of welding technology, photovoltaics and battery charging. Today, the
company has around 5,660 employees worldwide and 1,321 patents for product development show the innovative spirit within the company. Sustainable
development means for us to implement environmentally relevant and social aspects equally with economic factors. Our goal has remained constant throughout:
to be the innovation leader.
Fronius USA LLC
6797 Fronius Drive
Portage, IN 46368 USA
pv-support-usa@fronius.com
www.fronius.us
INPUT DATA PRIMO LITE 3.8-1 PRIMO LITE 5.0-1 PRIMO LITE 6.0-1 PRIMO LITE 7.6-1 PRIMO LITE 8.2-1
Recommended PV power (kWp) 3.0 - 6.0 kW 4.0 - 7.8 kW 4.8 - 9.3 kW 6.1 - 11.7 kW 6.6 - 12.7 kW
Max. usable input current (MPPT 1/MPPT 2) 18 A / 18 A
Max. usable input current (MPPT 1+MPPT 2) 36 A
Max. array short circuit current (1.5* lmax) (MPPT1/MPPT2) 27 A / 27 A
Nominal input voltage 410 V 420 V 420 V 420 V 420 V
Operating voltage range 80 V - 600 V
DC startup voltage 80 V
MPP Voltage Range 200 - 480 V 200 - 400 V 240 - 480 V 250 - 480 V 270 - 480 V
Max. input voltage 600 V (1,000 V optional
2
)
Admissible conductor size DC
AWG 14 - AWG 6 copper (solid / stranded / fine stranded) (AWG 10 copper or AWG 8 aluminium for overcurrent protective
devices up to 60 A, from 61 to 100 A minimum AWG 8 for copper or AWG 6 aluminium has to be used), AWG 6 - AWG 2 copper
(solid / stranded) Multi Contact Wiring able with AWG 12
Number of MPPT 2
OUTPUT DATA PRIMO LITE 3.8-1 PRIMO LITE 5.0-1 PRIMO LITE 6.0-1 PRIMO LITE 7.6-1 PRIMO LITE 8.2-1
Max. output power 208 V/240 V 3,800 VA/3,800 VA 5,000 VA/5,000 VA 6,000 VA/6,000 VA 7,600 VA/7,600 VA 7,900 VA/8,200 VA
Output configuration 208/240 V
Frequency range (adjustable) 45.0 - 55.0 Hz / 50 - 66 Hz
Operating frequency range default for CAL setups --/ 58.5 - 60.5 Hz
Operating frequency range default for HI setups --/ 57.0 - 63.0 Hz
Nominal operating frequency 60 Hz
Admissable conductor size AC AWG 14 - AWG 6
Total harmonic distortion < 5.0 %
Power factor range 0.85 - 1 ind./cap
Max. continuous output current 208 V 18.3 A 24.0 A 28.8 A 36.5 A 38.0 A
240 V 15.8 A 20.8 A 25.0 A 31.7 A 34.2 A
OCPD/AC breaker size 208 V 25 A 30 A 40 A 50 A 50 A
240 V 20 A 30 A 35 A 40 A 45 A
Max. Eciency 96.7 % 96.9 % 96.9 % 96.9 % 97.0 %
CEC Eciency 95.0 % 95.5 % 96.0 % 96.0 % 96.5 %
INPUT DATA PRIMO LITE 10.0-1 PRIMO LITE 11.4-1 PRIMO LITE 12.5-1 PRIMO LITE 15.0-1
Recommended PV power (kWp) 8.0 - 12.0 kW 9.1 - 13.7 kW 10.0 - 15.0 kW 12.0 - 18.0 kW
Max. usable input current (MPPT 1/MPPT 2) 33.0 / 18.0 A
Max. usable input current (MPPT 1+MPPT 2) 51 A
Max. array short circuit current (1.5 * Imax) 49.5 A / 27.0
Nominal input voltage 655 V 660 V 665 V 680 V
Operating voltage range 80 V - 1,000 V
DC startup voltage 80 V
MPP Voltage Range 220 - 800 V 240 - 800 V 260 - 800 V 320 - 800 V
Max. input voltage 1,000 V
Admissible conductor size DC
AWG 14 - AWG 6 copper direct, AWG 6 aluminum direct (AWG 10 copper or AWG 8 aluminium for overcurrent protective
devices up to 60 A, from 61 to 100 A minimum AWG 8 for copper or AWG 6 aluminium has to be used), AWG 4 - AWG 2 copper
or aluminum with optional input combiner
Number of MPPT 2
Integrated DC string fuse holders 4- and 4+ for MPPT 1 / no fusing required on MPPT 2
OUTPUT DATA PRIMO LITE 10.0-1 PRIMO LITE 11.4-1 PRIMO LITE 12.5-1 PRIMO LITE 15.0-1
Max. output power 208 V/240 V 9,995 VA/9,995 VA 11,400 VA/11,400 VA 12,500 VA/12,500 VA 13,750 VA/15,000 VA
Output configuration 1~NPE 208/240 V
Frequency range (adjustable) 45-55 Hz / 50 - 66 Hz
Operating frequency range default for CAL setups --/ 58.5 - 60.5 Hz
Operating frequency range default for HI setups --/ 57.0 - 63.0 Hz
Nominal operating frequency 60 Hz
Admissible conductor size AC
AWG 10- AWG 2 copper (solid/stranded/fine stranded) (AWG 10 copper or AWG 8 aluminum for overcurrent protective devices up to 60 A,
from 61 to 100 A minimum AWG 6 aluminum has to be used), AWG 6-AWG 2 copper (solid/stranded) Multi Contact Wiring able with AWG 12
Total harmonic distortion < 2.5 %
Power factor range 0-1 ind./cap.
Max. continuous output current 208 V 48.1 A 54.8 A 60.1 A 66.1 A
240 V 41.6 A 47.5 A 52.1 A 62.5 A
OCPD/AC breaker size 208 V 70 A 70 A 80 A 90 A
240 V 60 A 60 A 70 A 80 A
Max. Eciency 96.7 %
CEC Eciency 600 V/1,000 V 240 V 96.0 % / 96.5 % 96.5 % / 97.0 %
TECHNICAL DATA FRONIUS PRIMO LITE
2
inverter rated for up to 1,000 V open-circuit. Nominal, Operating, and MPP voltages based on 600 V system design. Actual DC system voltage is dependent on PV string-sizing, not inverter input capacity.