Technical Specifications

®™Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of DowPrinted in U.S.A.
Form No. 179-05044X-0311P&M
178-00582X-0311P&M
product information . commercial/residential . us/canada
SAFETY AND CONDITIONS
OF USE
Read the instructions and
Material Safety Data Sheets
carefully before use.
FROTH-PAK
spray polyurethane
foam contains isocyanate,
hydrofluorocarbon blowing
agent and polyol. Do not breathe
vapor or mist. Use only in well-
ventilated areas or with proper
respiratory protection. Supplied
air or an approved air-purifying
respirator equipped with an
organic vapor sorbent and a P100
particulate filter may be required
to maintain exposure levels below
ACGIH, OSHA, WEEL or other
applicable limits. For situations
where the atmospheric levels
may exceed the level for which
an air-purifying respirator is
effective, use a positive-pressure,
air-supplying respirator (air line
or self-contained breathing
apparatus).
Isocyanate is irritating to the
eyes, skin and respiratory system,
and may cause sensitization by
inhalation or skin contact.
FROTH-PAK
foam will adhere to
most surfaces and skin. Do not
get foam on skin. Wear protective
clothing (including long sleeves),
gloves, and goggles or safety
glasses. Cured foam must be
mechanically removed or allowed
to wear off in time.
The contents are under pressure.
FROTH-PAK
foam should
not be used around heaters,
furnaces, fireplaces, recessed
lighting fixtures or other applications
where the foam may come in
contact with heat-conducting
surfaces. Cured FROTH-PAK
foam is combustible and will burn
if exposed to open flame or sparks
from high-energy sources. Do not
expose to temperatures above
24F (116°C).
Visit www.dowbuildingsolutions.com or
contact a local Dow representative
for more specific instructions.
6 . AV A I L A B I L I T Y
FROTH- PAK
Foam Sealant is
distributed through an extensive
network. For more information, call:
1-800-232-2436 (English)
1-800-565-1255 (French)
7 . W A R R A N T Y
Not applicable.
8 . M A I N T E N A N C E
Not applicable.
9 . T E C H N I C A L
S E R V I C E S
Dow can provide technical
information to help address
questions when using FROTH- PAK
Foam Sealant. Technical personnel
are available. For technical
assistance, call:
1-866-583-BLUE (2583) (English)
1-800-363-6210 (French)
1 0 . F I L I N G S Y S T E M S
www.dowbuildingsolutions.com
www.sweets.com
www.dowbuildingsolutions.com
Technical Information
1-866-583-BLUE (2583) (English)
1-800-363-6210 (French)
Sales Information
1-800-232-2436 (English)
1-800-565-1255 (French)
IN THE U.S.
THE DOW CHEMICAL COMPANY
200 Larkin
Midland, MI 48674
IN CANADA
DOW CHEMICAL CANADA ULC
450 – 1st St. SW . Suite 2100
Calgary, AB T2P 5H1
NOTICE: No freedom from any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for
determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other
government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries
or regions. Dow assumes no obligation or liability for the information in this document. References to “Dow” or the “Company” mean the Dow legal entity selling the products to Customer unless otherwise expressly noted.
NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DOW. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
Dow Polyurethane Foam Insulation and Sealants
CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240ºF (116ºC). For more information, consult MSDS,
call Dow at 1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada.
FROTH-PAK™ spray polyurethane foam contains isocyanate, hydrofluorocarbon blowing agent and polyol. Read the instructions and Material Safety Data Sheets carefully before use. Wear protective clothing (including long
sleeves), gloves, goggles or safety glasses, and proper respiratory protection. Supplied air or an approved air-purifying respirator equipped with an organic vapor sorbent and a P100 particulate filter may be required to maintain
exposure levels below ACGIH, OSHA, WEEL or other applicable limits. Provide adequate ventilation. Contents under pressure.
Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential for mold formation. No material supplier including Dow can give assurance that mold will not develop in any
specific system.
TABLE 2: TYPICAL PHYSICAL PROPERTIES OF
FROTH-PAK
FOAM SEALANT
PROPERTY AND TEST METHOD VALUE
(1)
Flame Spread/Smoke Developed
(2)
, ASTM E84/UL 723 @ 4" wide by 2" thick 25/105
Nominal Density, ASTM D1622, lb/ft
3
1.75
Thermal Resistance
(3)
per inch, ASTM C518, ft
2
•h•°F/Btu, R-value, min.
Initial
Aged, LTTR measured at 2" thick
Aged, LTTR measured at 1" thick
6.0
5.5
5.3
Water Vapor Permeance, ASTM E96, perm @ 1" thick 3.13
Water Absorption, ASTM D2842, % by volume 5.44
Air Permeability, ASTM E2178 air leakage at 1" thick, l/min @ 75 Pa 0
Air Permeability, ASTM E283 air leakage at 0.5" thick, ft
3
/min•ft
2
@ 75 Pa 0
Dimensional Stability, ASTM D2126, % volume change
158°F/100% RH @ 1 wk
158°F/100% RH @ 2 wks
-40°F/amb RH @ 1 wk
-40°F/amb RH @ 2 wks
0.70
-0.06
0.02
0.36
Compressive Strength, ASTM D1621, lb/in
2
, parallel 23.4
Flexural Strength, ASTM C203, lb/in
2
, parallel 22.7
Tensile Strength, ASTM D1623, lb/in
2
, parallel 36
Shear Strength, ASTM C273, lb/in
2
, parallel 12.7
Maximum Service Temperature, °F 240
(1) Values may differ for FROTH-PAK™ 12 and specialty kits. Contact a Dow representative for more information.
(2) This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under
actual fire conditions.
(3) R means resistance to heat flow. The higher the R-value, the greater the insulating power.