Operating Manual

PRIVATE AND CONFIDENTIAL © 2019 FRTEK CO., LTD.
58
INOVA DAS Operating Manual
Alarm and Corrective Action
7.1 Alarm Phenomenon and Solution
7.1.1 TX/RX PLL Alarm
Phenomenon
Cause
- Alarm window: green red
- MHU : When TX PLL within MRFU is abnormal
- ERU : When TX PLL within ERFU is abnormal
Solution and Action
- Solution : Replace MRFU for MHU, replace ERFU for ERU
- Action : For MHU, replace MRFU of frequency band that alarm generated and check if it works
normally, for ERU, same as MHU, replace ERFU of frequency band that alarm generated
and check if it works normally
7.1.2 TX S/D(High) Alarm
Phenomenon
Cause
- Alarm window: green red
- When TX output level is higher than shutdown alarm set value
Solution and Action
- Solution: Set to appropriate TX ATTen.
- Action: Set TX ATTen. appropriately according to the environment, turn ALC on and prevent
shutdown.
7.1.3 DTU Alarm
Phenomenon
Cause
- Alarm window : green red
- When DTU board abnormality such as DTU board connection
harness, DTU board clock, DTU board telecommunication
abnormality occurs