Operating Manual
PRIVATE AND CONFIDENTIAL © 2019 FRTEK CO., LTD.
31
INOVA DAS Operating Manual
Item
Performance
requirements
Remark
Output level
Forward direction (DL)
+24dBm/Total
Tolerance : +1dB
Reverse direction (UL)
0dBm/Total
• Noise figure and spurious emission characteristics
Item
Performance
requirements
Remark
System noise figure (NF)
Reverse direction (UL)
Below 7dB
Maximum gain
Spurious emission
(within band)
±5.05MHz
Below -14dBm
Maximum output
RBW 100KHz
±10.05MHz
Below -14dBm
±15.5MHz
Below -16dBm
ACLR
BW
channel
45dBc
2 * BW
channel
45dBc
• Other performance requirements
Item
Performance
requirements
Remark
VSWR
Below 1.5 : 1
Transmit/receive separation
Over 100dBc
4.2 Organization Specification
4.2.1 Structure and Type
Item
Type
Option
MHU
19”Rack type
In-building type
EHUB
Wall fixed type
In-building type
ERU
Wall/ceiling fixed type
In-building type
• MHU, EHUB, ERU of INOVA DAS should be designed considering installation space and operator's
convenience, and the structure design should be elegant.
• Components of INOVA DAS should be modular, installation should be made in a structure that
each component can be easily mounted and dismounted, and should be easy to replace and
maintain.