Operating Manual

PRIVATE AND CONFIDENTIAL © 2021 FRTEK CO., LTD.
30
39GHz_L 5G Wireless Optical DAS Operating Manual
4.3 Electrical Specification
Power supplied to MPSU, DRU operates normally on commercial power supply (AC120/60Hz).
There is overvoltage and over current protection function for the power supply.
When after momentary power outage occurs, RF set value automatically returns to the status
right before the power outage.
Equipment grounding is located on both sides of the enclosure.
All components used on 39GHz_L 5G Wireless Optical DAS satisfies EMI terms of FCC title 47,
part 15, subject J, class A.
Grounding strap to ground the grounding wire of #6AWG must be attached to the enclosure.
4.4 Environmental Specification
No condensation traces may appear inside the unit when proceeding specified temperature and
humidity test.
It should be designed to prevent internal condensation and deterioration due to humidity and
internal/external temperature difference.
When proceeding specified vibration test, system performance and equipment damage should
not occur.
When proceeding specified waterproof test, there should be no trace of moisture penetration
inside the unit.
Environment test should be conducted in accordance with room temperature operation standard
(indoor only, outdoor standard when using enclosure).
Environment test item and method repetition period should follow operator environmental test
procedure..
39GHz_L 5G Wireless Optical DAS main environment test conditions are as below.
Item
Apply condition
Performance request
Operation
environment
test
In-building
- Temperature : -10 ~ +50C
- Humidity : 0 ~ 90% RH
- Output change : within ±3dB
- Enclosure inside/outside to have
no issue
Outdoor
- Temperature : -25 ~ +55C
- Humidity : 0 ~ 90% RH
- Output change : within ±3dB
- Enclosure inside/outside to have
no issue