39GHz_L 5G Wireless Optical DAS Operating Manual
on the 'GUI Tree'.
DTU
This item monitors overall status of the MDTU status. It can monitor status of 'OTX' and 'ORX' value
and alarm setting per optic branch, and is configured with 'Link Fail' alarm to check MDTU 'Status' ot
communication status.
MITU
This item is configured with an attenuator that can monitor and set power level of the IF signal
received from the MDU and DRU. Also, it is configured with 'OTX' alarm and 'ORX' alarm that can
monitor status or strength of the converted analog optic signal transmit/reception.
Also, it is configured with an attenuator to compensate uplink loss of fiber optic cable, and
implemented with 'Optic Comp.' function which is similar to 'Cable Comp.'. When turning this
function on, cable compensate attenuator is automatically set by auto measuring fiber optic cable
loss connected between MHU and DRU.
5.1.4 DRU Main Screen