39GHz_L 5G Wireless Optical DAS Operating Manual
Figure 13. DRU Main Screen.
Information
This item is configured with 'DC' alarm to monitor status of DC 37V supplied through the Bias-T,
and is implemented with 'Temp Comp.' to monitor the enclosure temperature and set temperature
table input value applicability. Also, it sets mRU status, and has Bias-T DC 37V on/off switch. When
there are 2 mRUs connected in the system, put 'mRU#1 Install' and mRU#2 Install' on and then can
check mRU 1 and mRU 2 applied on the 'GUI Tree'. Also when you turn mRU#1 Install and mRU#2
Install on and supply DC power to mRU, mRU will normally connect and you can check mRU 1 and
mRU 2 status on the 'GUI Tree' as alarm clear(green).
This item below 'Link Pilot' button is used for 'Cable Comp.' function so user does not control this
item.
DDTU
This item can monitor overall status of DDTU status. It can monitor status and set alarm of
connected optic branch 'OTX' and 'ORX' value, and is configured with 'Link Fail' alarm to check DDTU
'Status' or communication status..
MITU
This item is configured with an attenuator that can monitor IF signal strength or power level
received from the MHU and mRU. Also it is configured with 'OTX' alarm and 'ORX' alarm to monitor
strength and status of converted analog optic signal transmit/reception.
Also, it is configured with an attenuator to compensate downlink loss of fiber optic cable, and is
implemented with same function on the DRU as the MHU 'Optic Comp.'. When turning this function
on, cable compensate attenuator is automatically set by automatically measuring fiber optic cable loss
connected between MHU and DRU.
Cable Comp. Function
This item is the same function as MDU 'Cable Comp' function. When turning this function on, cable
compensate attenuator is automatically set by automatically measuring fiber optic cable loss