Operating Manual

PRIVATE AND CONFIDENTIAL © 2021 FRTEK CO., LTD.
40
39GHz_L 5G Wireless Optical DAS Operating Manual
mmWU
This item can monitor status of mmWave module within DU. It can monitor communication status
or module insert status between CPU and mmWave module. Also, when 10MHz Ref signal is not
normal, the 'PLL' alarm within the mmWave module occurs, and when this 'PLL' alarm occurs the
'Status' item alarm turns red.
RF Part
This item can monitor RF input signal and control signal level received from the DRU and the UE. It
is also configured with threshold value set item for ALC(Auto Level Control) function.
Also, it is configured with an attenuator that can compensate cable downlink loss connected
between mRU and DRU, and can compensate up to 12dB.
Function
This item can turn on/off ALC(Auto Level Control)' function according to the threshold value and
detected input signal value, and can set TDD sync signal mode received from the DRU.
- Auto : Sets sync signal to Auto Mode and switch.
- Tx CW : Output low level to set sync signal to DL Fix Mode
- Rx CW : Output high level to set sync signal to 'UL Fix Mode'