User's Manual
Table Of Contents
- Revision History
- Contents
- Chapter 1 Safety & Certification Notice 7
- 1.1 FCC Warning Statements 8
- 1.1.1 FCC Part 15.105 statement 8
- 1.1.2 FCC Part 15.21 statement 8
- Chapter 2 System Overview 10
- 2.1 System Overview 11
- 2.1.1 ICS Repeater Installation Location 11
- 2.1.2 ICS Repeater General Information 11
- Chapter 3 System Configuration 13
- 3.1 System Figuration 14
- 3.2 System Module Configuration 15
- 3.3 System Port Configuration 15
- 3.4 AC Power Cable 16
- 3.5 Antenna 17
- Chapter 4 System Specification 18
- 4.1 RF Specification 19
- 4.2 Power Specification 20
- 4.3 Environment Specification 21
- Chapter 5 FR-RLRL45US Installation 22
- 5.1 Installation 23
- 5.1.1 Grounding Connection 23
- 5.1.2 Antenna Connection 23
- 5.1.3 AC Power Connection 24
- Figures
- Figure 1. ICS Repeater Service Application Network 11
- Figure 2. Repeater Figuration 14
- Figure 3. ICS Repeater External Port Configuration 15
- Figure 4. AC Power Cable 16
- Figure 5. RET Port Connector(SU-20SPR-8S) Pin Map 17
- Figure 6. Connection of grounding cable 23
- Figure 7. ICS Antenna Cable Connection. 23
- Used Abbreviations
- Chapter 1 Safety & Certification Notice
- Safety & Certification Notice
- Chapter 2 System Overview
- System Overview
- Chapter 3 System Configuration
- System Configuration
- Chapter 4 System Specification
- System Specification
- Chapter 5 FR-RLRL45US Installation
- FR-RLRL45US Installation
PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
20
FR-RLRL45US
Operating Manual
This system complies with prescribed gain control and input/output function specification.
Items Specification Remark
Gain control range
65 ~ 105 dB DL / UL
Gain control gap
0.5 dB /Step
Gain control error
Below ±0.5dB /Step
Input Range
DL -60.3dBm/Total
UL -72dBm/Total
Output Level
DL
30Watt/Total
(44.7dBm /Total)
UL
2Watt/Total
(33dBm /Total)
Shut-down
Function
DL
Over 45.7dBm
/ Total
Can configure
shut-down level
UL 34dBm / Total
System Noise Figure Within 4dB
System Delay
Period
CDMA ≤ 4.0usec DL / UL
LTE (5M / 10M) ≤ 4.0usec DL / UL
Standing wave ratio (VSWR) ≤ 1.5:1 DL / UL
ALC Range ≥ 30dB DL / UL
Feedback signal remove function G=I+15dB
※ Maximum DL output power is 30Watt/Total
- In case of 3 blocks : 10Watt (40dBm) per block
- In case of 2 blocks : 15Watt (41.76dBm) per block
- In case of 1 block : 20Watt (43.01dBm) per block
※ Maximum UL output power is 2Watt/Total
- In case of 3 blocks : 0.67Watt. (28.26dBm) per block
- In case of 2 blocks : 1Watt (30dBm) per block
- In case of 1 block : 1.33Watt (31.23dBm) per block