User's Manual

Table Of Contents
PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
20
FR-RLRL45US
Operating Manual
This system complies with prescribed gain control and input/output function specification.
Items Specification Remark
Gain control range
65 ~ 105 dB DL / UL
Gain control gap
0.5 dB /Step
Gain control error
Below ±0.5dB /Step
Input Range
DL -60.3dBm/Total
UL -72dBm/Total
Output Level
DL
30Watt/Total
(44.7dBm /Total)
UL
2Watt/Total
(33dBm /Total)
Shut-down
Function
DL
Over 45.7dBm
/ Total
Can configure
shut-down level
UL 34dBm / Total
System Noise Figure Within 4dB
System Delay
Period
CDMA ≤ 4.0usec DL / UL
LTE (5M / 10M) ≤ 4.0usec DL / UL
Standing wave ratio (VSWR) ≤ 1.5:1 DL / UL
ALC Range ≥ 30dB DL / UL
Feedback signal remove function G=I+15dB
Maximum DL output power is 30Watt/Total
- In case of 3 blocks : 10Watt (40dBm) per block
- In case of 2 blocks : 15Watt (41.76dBm) per block
- In case of 1 block : 20Watt (43.01dBm) per block
Maximum UL output power is 2Watt/Total
- In case of 3 blocks : 0.67Watt. (28.26dBm) per block
- In case of 2 blocks : 1Watt (30dBm) per block
- In case of 1 block : 1.33Watt (31.23dBm) per block