PSU output voltage decreases 85% or under
Appropriate Measures
Solution : Replacing PSU
- Measures : Check the operation by repacing PSU
(3) LD Alarm (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
LD of optical module is not normal
Appropriate Measures
Solution : Replacing optical module
Measures : Check the operation by repacing optical module
(4) PD Alarm (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
PD of optical module is not normal
Appropriate Measures
Solution : Clean optical connector and check optical cable or replacing optical moduel
Measures : Clean optical connector, check the optic cable and fix the problem.
If there is no falut, replace the optical module.
(5) TX/RX PLL (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
MHU: Has the problem at TX PLL in MUDC(750M/800M/1.9G/2.1G)
ROU 10W: Has the problem at TX PLL in RRFU intergrated moduel Converter
Appropriate Measures
Solution : MHU- Replacing MRFU(750M/800M/1.8G/2.1G)
ROU - Replacing RRFU intergrated module Converter(750M/800M/1.8G/2.1G)
Measures : MHU- Check the operation by repacing MUDC(750M/800M/1.8G/2.1G) of Path(alarm occuring)
ROU 10W- Check the operation by repacing RRFU intergrated module
converter(750M/800M/1.8G/2.1G)
(6) Internal FAN (MHU, ROU 10W)
Phenomenon
Alarm window : GREEN → RED
Causes
Occuring some problems at internal fan