- PSU output voltage decreases 85% or under
■ Appropriate Measures
- Solution : Replacing PSU
- Measures : Check the operation by repacing PSU
(3) LD Alarm (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- LD of optical module is not normal
■ Appropriate Measures
- Solution : Replacing optical module
- Measures : Check the operation by repacing optical module
(4) PD Alarm (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- PD of optical module is not normal
■ Appropriate Measures
- Solution : Clean optical connector and check optical cable or replacing optical moduel
- Measures : Clean optical connector, check the optic cable and fix the problem.
If there is no falut, replace the optical module.
(5) TX/RX PLL (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- MHU: Has the problem at TX PLL in MUDC(750M/800M/1.9G/2.1G)
- ROU 10W: Has the problem at TX PLL in RRFU intergrated moduel Converter
■ Appropriate Measures
- Solution : MHU- Replacing MRFU(750M/800M/1.8G/2.1G)
ROU - Replacing RRFU intergrated module Converter(750M/800M/1.8G/2.1G)
- Measures : MHU- Check the operation by repacing MUDC(750M/800M/1.8G/2.1G) of Path(alarm occuring)
ROU 10W- Check the operation by repacing RRFU intergrated module
converter(750M/800M/1.8G/2.1G)
(6) Internal FAN (MHU, ROU 10W)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- Occuring some problems at internal fan