User's Manual
Sierra ROU 10W User Manual
© FRTek Co. Ltd 2015
33
Confidential: Any reproduction or distribution without the express written consent of FRTek Co. Ltd
or FRTek US LLC is strictly prohibited
■ Appropriate Measures
- Solution : Check and replace the FAN
- Measures : Check the operation by chekcing and repacing the fan
(7) External FAN (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- Occuring some problems at external fan
■ Appropriate Measures
- Solution : FAN Check and replace
- Measures : Check the operation by chekcing and repacing the fan
(8) TX S/D(High) (ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- TX output is higher than alarm setting value
■ Appropriate Measures
- Solution : Set appropriate TX ATT
- Measures : Setting the TX ATT in accordance with environment and truning ALC on to prevent to be S/D.
(9) DTU Status (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- Occur the problems at harbness connected DTU board or DTU board
■ Appropriate Measures
- Solution : Replacing the harbness connected DTU, if it still has the problem, replace the DTU board
- Measures : Check the operation by replacing the harbness connected DTU or DTU board.
(10) DTU Link Fail (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- Occur the problems of link fail between DTU board and CPU
■ Appropriate Measures
- Solution : Check Reference clock or Check the connectivity between DTU board and Back Board
- Measures : Check the connectivity status of DTU board and replace DTU board.
(11) VSWR (ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes