User's Manual

Sierra ROU 40W User Manual
© FRTek Co. Ltd 2015
33
Confidential: Any reproduction or distribution without the express written consent of FRTek Co. Ltd
or FRTek US LLC is strictly prohibited
7. Alarm and Troubleshooting
(1) AC (MHU, ROU)
Phenomenon
PSU LED : PSU AC LED Off
Alarm window : GREEN → RED
Causes
Input power 120V/AC is not normally enters
Appropriate Measures
Solution : Check the Input power 120V/AC
- Measures : Check the input power 120V/AC, if there is no problems, check the operation by replacing PSU.
(2) DC (MHU, ROU)
Phenomenon
PSU LED : PSU DC LED RED
Alarm window : GREEN → RED
Causes
PSU output voltage decreases 85% or under
Appropriate Measures
Solution : Replacing PSU
- Measures : Check the operation by repacing PSU
(3) LD Alarm (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
LD of optical module is not normal
Appropriate Measures
Solution : Replacing optical module
Measures : Check the operation by repacing optical module
(4) PD Alarm (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
PD of optical module is not normal
Appropriate Measures
Solution : Clean optical connector and check optical cable or replacing optical moduel
Measures : Clean optical connector, check the optic cable and fix the problem.
If there is no falut, replace the optical module.
(5) TX/RX PLL (MHU, ROU)
Phenomenon