User's Manual
Sierra ROU 40W User Manual
© FRTek Co. Ltd 2015
34
Confidential: Any reproduction or distribution without the express written consent of FRTek Co. Ltd
or FRTek US LLC is strictly prohibited
- Alarm window : GREEN → RED
■ Causes
- MHU: Has the problem at TX PLL in MUDC(750M/800M/1.9G/2.1G)
- ROU 10W: Has the problem at TX PLL in RRFU intergrated moduel Converter
■ Appropriate Measures
- Solution : MHU- Replacing MRFU(750M/800M/1.8G/2.1G)
ROU - Replacing RRFU intergrated module Converter(750M/800M/1.8G/2.1G)
- Measures : MHU- Check the operation by repacing MUDC(750M/800M/1.8G/2.1G) of Path(alarm occuring)
ROU 10W- Check the operation by repacing RRFU intergrated module
converter(750M/800M/1.8G/2.1G)
(6) Internal FAN (MHU, ROU 10W)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- Occuring some problems at internal fan
■ Appropriate Measures
- Solution : Check and replace the FAN
- Measures : Check the operation by chekcing and repacing the fan
(7) External FAN (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- Occuring some problems at external fan
■ Appropriate Measures
- Solution : FAN Check and replace
- Measures : Check the operation by chekcing and repacing the fan
(8) TX S/D(High) (ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- TX output is higher than alarm setting value
■ Appropriate Measures
- Solution : Set appropriate TX ATT
- Measures : Setting the TX ATT in accordance with environment and truning ALC on to prevent to be S/D.
(9) DTU Status (MHU, ROU)
■ Phenomenon
- Alarm window : GREEN → RED
■ Causes
- Occur the problems at harbness connected DTU board or DTU board