Alarm window : GREEN → RED
Causes
MHU: Has the problem at TX PLL in MUDC(750M/800M/1.9G/2.1G)
ROU 10W: Has the problem at TX PLL in RRFU intergrated moduel Converter
Appropriate Measures
Solution : MHU- Replacing MRFU(750M/800M/1.8G/2.1G)
ROU - Replacing RRFU intergrated module Converter(750M/800M/1.8G/2.1G)
Measures : MHU- Check the operation by repacing MUDC(750M/800M/1.8G/2.1G) of Path(alarm occuring)
ROU 10W- Check the operation by repacing RRFU intergrated module
converter(750M/800M/1.8G/2.1G)
(6) Internal FAN (MHU, ROU 10W)
Phenomenon
Alarm window : GREEN → RED
Causes
Occuring some problems at internal fan
Appropriate Measures
Solution : Check and replace the FAN
Measures : Check the operation by chekcing and repacing the fan
(7) External FAN (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
Occuring some problems at external fan
Appropriate Measures
Solution : FAN Check and replace
Measures : Check the operation by chekcing and repacing the fan
(8) TX S/D(High) (ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
TX output is higher than alarm setting value
Appropriate Measures
Solution : Set appropriate TX ATT
Measures : Setting the TX ATT in accordance with environment and truning ALC on to prevent to be S/D.
(9) DTU Status (MHU, ROU)
Phenomenon
Alarm window : GREEN → RED
Causes
Occur the problems at harbness connected DTU board or DTU board