- Housing, component, PCB, solder, cable, etc. that are applied to the device shall be in accordance with current
RoHS (Restriction of Hazardous Substances Directive).
-
4.1.5 Electrical conditions
- MHU, ROU operate normally in the commercial power supply (AC120 / 60Hz). (Considering of the
photoelectric composite cable power input)
- ROU can be operated with the external back-up battery only
- The power wiring should be attached to the inside of the door, designed to prevent damage.
- There is a function of overvoltage and overcurrent protection in the DC inputs.
- Withstand voltage is applied to the input and output 3KV for 1 minute, the leakage current is less than 10mA.
- Lleakage current is less than 3.5mA in the phase transition (120V).
- There should be no damage in case of 5 times surge voltage shock - 4kV at AC input port and 4kV at DC input
port.
- Grounding of equipment is separated; communication ground and power ground.
- Fuse must be able to determine whether or not a problem with the naked eye, it can be replaced without
dismantling the equipment.
- All parts used in this repeater meet the conditions of FCC Regulations Title 47, Part 15, Subject J, and EMI Class
B.
- Ground cables equivalent to #6AWG should be installed with a ground table into an enclosure.
4.1.6 Management and monitoring
- SIERRA can be configured up to the GUI for 1pc of MHU,64 pcs ROUs. Status Monitoring and Control is
enabled.
- SIERRA is designed to maintain the previous states such as setting up the device parameters and operating
conditions during recovery after a power outage.
- SIERRA is upper interworking by MHU and EMS Server
- A system control is possible by an operator using a Local GUI or Web GUI.