6.1 ROU 40W Installation
6.3.1 ROU 40W Configuration
ROU 40W is configured of 6 pcs RF modules, Digital Board, CPU, PSU, Optic Switch and Optic module.
ROU 40W supports 4 bands and is expandable to 2 more bands - 700MHz and 2.1GHz with MIMO service
ROU 40W can service up to 4 service providers per each band and the maximum output per band is up to 40W.
The definition of ROU 40W module is as following.
ROU 40W is powered by AC 120V(55 ~ 65Hz) and it also connects to battery backup port depending on the
installation environment. AC 120V power connector is located under the outdoor enclosure and the connector
recommended is MS3106A-16-10S(F) connecting to power distribution panel.
Maximum output per each service provider shall be limited up to 10W.