PrimAer 28GHz Operating Manual
Figure 5. SU Port Configuration.
Item
Content
Port to transmit/receive optic signal
Port to monitor T-SYNC
Port to monitor Downlink SISO Path RF signal
Port to monitor Downlink MIMO Path RF signal
Port to monitor internal 10MHz Reference signal
Port to supply -53.3V power from the Rectifier
Port to connect to GUI (Connect when cover is open)
Internal antenna, transmit/receives RF wireless signal
3.3 Rectifier Details and Configuration
The Rectifier is a unit to supply power to the DU and SU. The Rectifier consists of One enclosure with
a mounting bracket enabling wall attachment
It receives input AC 100 ~ 240V power, and outputs DC -53.3V voltage to total of 5 ports (Port 1 ~
4, AC 100 ~ 240V input, Battery connection as shown in Figure 7). It supplies power to the DU and SU
through a power cable.