Operating Manual

PRIVATE AND CONFIDENTIAL © 2020 FRTEK CO., LTD.
29
PrimAer 28GHz Operating Manual
4.4 Environmental Specification
There must not be any condensation traces inside the equipment when proceeding with specified
temperature and humidity tests.
It must be designed so that there are no internal condensation and function reduction due to
humidity and internal/external temperature difference when it is not operated normally.
When proceeding specified vibration test, there should be no system performance or equipment
damage.
When proceeding specified waterproof test, there should be no trace of moisture penetration inside
the equipment.
Environmental test must be conducted in accordance with room temperature standard(in-building
standard, for external enclosure outdoor standard).
For the environment test items and method repeat cycle follow the operator environment test
procedure.
PrimAer 28 main environment terms are as below.
Item
Application Term
Performance Requirements
Operation
environment
test
In-building
- Temperature : -10 ~ +50C
- Humidity : 0 ~ 90% RH
- Output change : within ±3dB
- No abnormalities on enclosure
inside/outside
Outdoor
- Temperature : -25 ~ +55C
- Humidity : 0 ~ 90% RH
- Output change : within ±3dB
- No abnormalities on enclosure
inside/outside