Operating Manual

PRIVATE AND CONFIDENTIAL © 2020 FRTEK CO., LTD.
61
PrimAer 28GHz Operating Manual
AOM
This item is configured with the 'LD' alarm and 'PD' alarm which can monitor the SU's internal analog
optic module RF & optic's SISO path / MIMO path DL/UL real-time RF output, and converted analog
optic signal transmission/reception strength, along with Array Ant. atten control, ATT control, ALC limit
level setting, and ALC on/off.
- DL Output : AOM SISO/MIMO IF DL output real-time monitoring
- DL ATT : AOM SISO/MIMO IF DL Atten control
- DL ISO ATT : AOM SISO/MIMO IF DL Isolation Atten monitoring
- UL Output : AOM SISO/MIMO IF UL output real-time monitoring
- UL ATT : AOM SISO/MIMO IF UL Atten control
- UL Cas ATT : AOM SISO/MIMO IF UL Cascade Atten control
- ALC Limit Level : AOM SISO/MIMO IF ALC limit level setting
- ALC On/Off : AOM SISO/MIMO IF ALC function On/Off control
- Front End ATT : Array Ant. DL/UL SISO/MIMO Atten control
- LD : AOM SISO/MIMO DL LD Power real-time monitoring
- LD Lower : AOM SISO/MIMO DL LD Power lower value setting and alarm display
- PD : AOM SISO/MIMO UL PD Power real-time monitoring
- PD Lower : AOM SISO/MIMO UL PD Power lower value setting and alarm display
- Next LD : Cascaded SU AOM SISO/MIMO DL LD Power real-time monitoring
- Next LD Lower : Cascaded SU AOM SISO/MIMO DL LD Power lower value setting and alarm display
- Next PD : Cascaded SU AOM SISO/MIMO UL PD Power real-time monitoring
- Next PD Lower : Cascaded SU AOM SISO/MIMO UL PD Power lower value setting and alarm display