Manual
2-7
The FilterQuickâ„¢ FQG30 Series gas fryer has received the CE mark for the countries and gas
categories indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for
AT, DE, LU and category 3P/B, which is 23kW.
NOTICE- Australia Only
The air pressure switch on the combustion blower should read: Full Vat units-122pa
(0.5 inches W.C.) and for Split Vat units-180pa (0.72 inches W.C.).
COUNTRIES CATEGORIES GAS PRESSURE (MBAR)
AUSTRIA (AT) II2H3B/P
G20 20
G30, G31 50
BELGIUM (BE)
I2E(R)B G20, G25 20, 25
I3+ G30, G31 28-30, 37
DENMARK (DK) II2H3B/P
G20 20
G30, G31 30
FRANCE (FR)
II2Esi3+
G20, G25 20, 25
G30, G31 28-30, 37
II2Esi3P
G20, G25 20, 25
G31 50
FINLAND (FI) II2H3B/P
G20 20
G30, G31 30
GERMANY (DE)
II2ELL3B/P
G20, G25 20
G30, G31 50
I3P G31 50
GREECE (GR) II2H3+
G20 20
G30, G31 28-30, 37
ITALY (IT) II2H3+
G20 20
G30, G31 28-30, 37
IRELAND (IE) II2H3+
G20 20
G30, G31 28-30, 37
LUXEMBOURG (LU) II2E3B/P
G20 20
G30, G31 50
NETHERLANDS (NL)
II2L3P
G25 25
G31 50
II2L3B/P
G25 25
G30, G31 30
NORWAY (NO) I3B/P G30, G31 30
PORTUGAL (PT) II2H3+
G20 20
G30, G31 28-30, 37
SPAIN (ES)
II2H3+
G20 20
G30, G31 28-30, 37
II2H3P
G20 20
G31 37, 50
SWEDEN (SE) II2H3B/P
G20 20
G30, G31 30
UNITED KINGDOM (UK) II2H3+
G20 20
G30, G31 28-30, 37
CE Standard
Required airflow for the combustion air supply is 2m
3
/h per kW.
1. Connect the quick-disconnect hose to the fryer quick-disconnect under the fryer and to the
building gas line.
NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units
are connected to the gas supply line at the rear of the unit.
CE Approved Gas Categories by Country