Manual
6-6
One vat doesn’t top off.
A. Filter error exists.
B. Service required error exists
C. Solenoid, pump, pin issue, RTD
or ATO issue.
A. Clear filter error properly. If problem persists
call your FAS for assistance.
B. Call your FAS for assistance.
C. Call your FAS for assistance.
Controller displays
TOPOFF OIL
EMPTY /
CONFIRM
Top off system out of oil.
Fill top off system with oil and press the
(CONFIRM) button. Once the JIB is replaced press
and hold the orange reset button for ten (10)
seconds to reset top off system.
6.2.6 Error Log Codes (For FilterQuick™ Controller Only)
Code ERROR MESSAGE EXPLANATION
E03 ERROR TEMP PROBE FAILURE Temp probe reading out of range
E04 HI 2 BAD High limit reading is out of range.
E05 HOT HI 1
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
E06 HEATING FAILURE A component has failed such as controller,
interface board, gas valve, ignition module or
open-high limit.
E07 ERROR MIB SOFTWARE Internal MIB software error
E08 ERROR ATO BOARD ATO board connection lost; ATO board failure
E09 ERROR PUMP NOT FILLING Dirty paper/pad and it needs changed or it was
bypassed; filter pump problem
E10 ERROR DRAIN VALVE NOT OPEN Drain valve was trying to open and
confirmation is missing
E11 ERROR DRAIN VALVE NOT CLOSED Drain valve was trying to close and
confirmation is missing
E12 ERROR RETURN VALVE NOT OPEN Return valve was trying to open and
confirmation is missing
E13 ERROR RETURN VALVE NOT CLOSED Return valve was trying to close and
confirmation is missing
E14 ERROR AIF BOARD MIB detects AIF missing; AIF board failure
E15 ERROR MIB BOARD Cooking controller detects MIB connections
lost; Check software version on each
controller. If versions are missing, check CAN
connections between each controller; MIB
board failure
E16 ERROR AIF PROBE AIF RTD reading out of range
E17 ERROR ATO PROBE ATO RTD reading out of range
E20 INVALID CODE LOCATION SD card removed during update
E21 FILTER PAPER PROCEDURE ERROR
(Change Filter Paper)
25 hour timer has expired or a dirty filter may
be causing an incomplete filtration.