Code ERROR MESSAGE EXPLANATION
E22 OIL IN PAN ERROR Oil may be present in the filter pan.
E23 CLOGGED DRAIN (Gas) Vat did not empty during filtration
E24 OIL LEVEL SENSOR FAILED (Gas) Oil level sensor failed.
E25 RECOVERY FAULT Recovery time exceeded maximum time limit.
Recovery time should not exceed 2:25 for gas.
E27 LOW TEMP ALARM Oil temperature has dropped 30°F (17°C)
lower than setpoint in idle mode or 45°F
(25°C) in cook mode. (This message may
appear if a product is dropped and the start
cook button is not pressed immediately or if
too large of cook loads are dropped.)
E28 HIGH TEMP ALARM Oil temperature has risen 40°F (22.2°C) higher
than
setpoint. If temperature continues to rise, the high
limit will shut the burner off when temperature
reaches 425°F (218°C) Non-CE or 395°F (202°C)
CE.
6.2.7 HIGH-LIMIT TEST MODE
The high-limit test mode is used to test the high limit circuit. The high-limit test will destroy the oil.
It should only be performed with old oil. Shut the fryer off and call for service immediately if the
temperature reaches 460°F (238°C) without the high-limit tripping and the computer displays high
LIMIT FAILURE alternating with DISCONNECT POWER with an alert tone during testing.
The test is cancelled at any time by turning the fryer off. When the fryer is turned back on, it returns
to the operating mode and displays the product.
1. Press and hold the check () button until MAIN MENU is displayed followed by PRODUCT
SETUP.
2. Press the left arrow () button until TECH MODE is displayed.
3. Press the check () button.
4. Enter 3000.
5. Press the left arrow () button until HI LIMIT TEST is displayed.
6. Press the check () button.
The controller displays HIGH LIMIT YES/NO.
7. Press the up arrow () button.
8. The controller displays PRESS AND HOLD CHECK.