2-3 
2.2 Power Requirements 
AMPS PER LEG 
VOLTAGE PHASE 
WIRE 
SERVICE 
MIN. 
SIZE 
AWG 
(mm
2
) 
L1 L2  L3 
208  3  3  6 (16) 39 39  39 
240  3  3  6 (16) 34 34  34 
480  3  3  8 (10) 17 17  17 
220/380 3  4  6 (16) 21 21  21 
240/415 3  4  6 (16) 20 20  21 
230/400 3  4  6 (16) 21 21  21 
The three phase supply plug for the elements is rated at 60 amps, 250 VAC and is NEMA 
configuration L15-60P. The control and filter plug is rated at 20 amps, 120/208 VAC and is NEMA 
configuration L21-20P. Each fryer should have its cord for the element supply on an individual 
circuit as well as the control cord. 
NOTICE 
If this appliance is permanently connected to fixed wiring, it must be connected by 
means of copper wires having a temperature rating of not less than 167°F (75°C). 
 DANGER 
This appliance must be connected to a power supply having the same voltage and 
phase as specified on the rating plate located on the inside of the appliance door. 
 DANGER 
All wiring connections for this appliance must be made in accordance with the 
wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) 
affixed to the inside of the appliance door when installing or servicing this 
equipment. 
2.3  After Fryers Are Positioned At the Frying Station 
 DANGER 
No structural material on the fryer should be altered or removed to accommodate 
placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service 
Hotline at 1-800-551-8633. 
1.  Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the 
top of the frypot to verify that the unit is level, both side-to-side and front-to-back. 
To level fryers, adjust the casters being careful to ensure the fryer(s) are at the proper height in 
the frying station. 
When the fryer is leveled in its final position, install the restraints provided with the unit to limit 
its movement so that it does not depend on or transmit stress to the electrical conduit or 
connection. Install the restraints in accordance with the provided instructions (see illustration on 
the following page). If the restraints are disconnected for service or other reasons, they must be 
reconnected before the fryer is used. 