Quick Specs

Options & Accessories
Split frypots
External oil discharge -- available on built-in filter batteries of 2 or more frypots or a
frypot/spreader -- must specify front or rear connection
Automatic basket lifts (units with basket lifts require CM3.5 or 3000 controller to be
purchased also)
RE Controllers: CM3.5, SMART4U® 3000, Digital. RETC -- no controller options
Spreader cabinet -- must fit within a 6-cabinet fryer battery
Frypot cover(s)
Full basket
Triplet basket
Crisper tray
Sediment tray
Splash shield
BASIC
DOMESTIC
kw
ELEMENTS/FRYPOT
CONTROLS/
FRYPOT
FILTER
BASKET
LIFTS/
FRYPOT
VOLTAGE 3 PHASE*
1
PHASE**
RE14
RE14TC***
14
208V
240V
480V
39 A
34 A
17 A
67 A
58 A
N/A
1 A
1 A
120V 1 A
5 A
4 A
120V 8 A
2 A
2 A
120V 3 A
RE14-2
RE14-2TC***
7
RE17
RE17TC***
17
208V
240V
480V
48 A
41 A
21 A
82 A
71 A
N/A
1 A
1 A
120V 1 A
5 A
4 A
120 V 8 A
2 A
2 A
120V 3 A
RE17-2
RE17-2TC***
8.5
RE22
RE22TC***
22
208V
240V
480V
61 A
53 A
27 A
106 A
92 A
N/A
1 A
1 A
120V 1 A
5 A
4 A
120 V 8 A
2 A
2 A
120V 3 A
RE22-2
RE22-2TC***
11
BASIC EXPORT & CE
RE14
RE14TC
14
220V/380V
230V/400V
240V/415V
250/430V****
22 A
21 A
20 A
20 A
N/A
1 A
1 A
1 A
1 A
4 A
4 A
4 A
4 A
2 A
2 A
2 A
2 A
RE14-2
RE14-2TC
7
RE17
RE17TC
17
220V/380V
230V/400V
240V/415V
250/430V****
26 A
25 A
24 A
25 A
N/A
1 A
1 A
1 A
1 A
4 A
4 A
4 A
4 A
2 A
2 A
2 A
2 A
RE17-2
RE17-2TC
8.5
RE22
RE22TC
22
220V/380V
230V/400V
240V/415V
250/430V****
34 A
32 A
31 A
32 A
N/A
1 A
1 A
1 A
1 A
4 A
4 A
4 A
4 A
2 A
2 A
2 A
2 A
RE22-2
RE22-2TC
11
RE Electric Fryer Batteries with Filtration
POWER REQUIREMENTS
8700 Line Avenue
Shreveport, LA 71106-6800
USA
Tel: 318-865-1711
Tel: 1-800-221-4583
Fax: 318-868-5987
E-mail: info@frymaster.com
www.frymaster.com
Bulletin No. 818-0434
Revised 8/3/15
NOTES
TC models not available in 480V.
One cord is provided per full and dual split frypot on 3 phase 14 kw models.
Cord is provided on 3 phase units with exception of items in red (see chart above).
Plug is optional accessory on units shipping with cord. Canada is an exception and cords, where
available, must have a plug attached.
Optional plug -- (Domestic NEMA #15-60P).
All 22 kw and single phase units must be eld wired. No cord or plug provided. Check electrical codes for proper
supply line sizing. Single phase fryers with single lter available in 240V and 208V only.
Controller, filter pump and basket lifts are powered by element voltages except for 480V fryers.
All 480 volt models are provided with separate 120 volt cord and plug for lter pump, and/or controller, and/or
basket lifts.
CLEARANCE INFORMATION
A minimum of 24” (61 cm) should be provided at the front of the unit for servicing and proper operation, 6” (15.2 cm)
between the sides and rear of the fryer to any combustible material.
We reserve the right to change specications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
Check www.frymaster.com for updates.
*3 PH/3 Wire/Plus Ground Wire.
**1 PH/2 Wire/Plus Ground Wire.
***TC models not available in 480V.
**** Australia filter models only -- when operating at 250V, elements will be rated at approximately
15.2/18.5/23.9 kw.