Super Cascade Filtration Systems (CE) Operation Manual CE ONLY Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 24-Hour Service Hotline 1-800-551-8633 Price: $6.
SUPER CASCADE FILTRATION SYSTEM OPERATION MANUAL TABLE OF CONTENTS 1. 2. 3. 4. 5. 6. PARTS ORDERING AND SERVICE INFORMATION GENERAL FILTER PREPARATION FILTER OPERATIONS FILTER TROUBLESHOOTING WIRING DIAGRAM PAGE 1 2 2 3 5 10 1. PARTS ORDERING AND SERVICE INFORMATION 1.1 ORDERING PARTS: Customers may order parts directly from their local Authorized Parts Distributor. For this address and phone number, contact your Maintenance & Repair Center or call the factory.
2. GENERAL: a. The Flatbottom 24G (CE)/H250 Fryer System is equipped with the Super Cascade Filter Model 99. b. For consistent product quality, convenience and long-term savings, use a high-quality liquid frying compound. c. The frying compound should be filtered at least daily or even more frequently if cooking is heavy. This ensures the longest life possible for the frying compound, gives better taste to the food being prepared, and minimizes flavors being transferred from batch to batch. d.
f. Unlatch and remove the hold down ring. Remove and discard old filter paper sheet from the filter pan. g. Clean out the filter pan. h. Place one sheet of filter paper in the bottom of the filter pan. Reinstall and latch the hold down ring into position. i. Sprinkle 8 ounces (1 cup)/ 227 grams evenly over the paper. Return cover to the filter pan. Hold down ring latched into position. j.
4. Open the oil return valve by turning the smaller red handle located under the control panel of the fryer. Move the handle left to right to open the oil return line. This will activate the filter pump also. Oil return handle Flatbottom Drain Valve in Closed Position Flatbottom 24G 5. If the circuit breaker kicks out, this often means that there is an obstruction in the oil return lines.
b. H250 Fryers: 1. Turn the lower red drain valve handle from left to right to open the drain valve. The photo below shows the drain valve in the open position. 2. Stir the oil in the frypot with the L-shaped teflon brush as the oil drains into the filter pan. Brush down the vessel sides to remove debris. Use the clean-out rod to clear the drain if necessary. 3. Open the oil return valve by turning the smaller red handles located under the frypot.
5. FILTER TROUBLESHOOTING: The problems and possible solutions covered are those most commonly encountered. To troubleshoot, perform the test set-up at the beginning of each condition. Start at the top of the diagram. Arrows direct the troubleshooter through the sequence. Follow each step in sequence as shown in the troubleshooting diagrams. Troubleshooting Diagram Index Section 5.1 5.2 5.
5.2 RATE OF OIL RETURN SLOWING? Rate of oil return to the fryer is slowing. Is this the first fryer to be filtered in this filtering session? No Check the filter sump. Sediment collects around the suction pipe in the filter pan bottom. Remove the filter pan cover. Yes Unlatch hold down ring and remove filter paper and filter paper support grid. Check the filter paper in the filter pan. Is the filter paper properly secured by the hold down ring? No Clean support grid and set aside temporarily.
5.3 BLOCKAGE BETWEEN FILTER PAN AND OIL RETURN VALVE? Blockage has been determined to be between the filter pan bottom and the oil return valve. Disconnect oil line running from the filter pan to the pump at the pump end. Activate pump by turning oil return valve handle. No Does the pump motor run? Check filter circuit breaker. Push the filter circuit breaker reset button located in the right-hand fryer. Yes Activate pump by turning oil return valve handle.
Enter from page 8 here. DANGER! NEVER USE A PROPANE TORCH TO MELT SOLIDIFIED SHORTHENING IN ANY PART OF THE SYSTEM. YOU WOULD BE USING AN OPEN FLAME NEAR COMBUSTIBLES. THE FIRE HAZARD IS EXTREME! Plug is in the bottom of the filter pan or in the line from the filter to the pump. Disconnect the tubing from the filter pan to the motor. Make sure the pipe is cool. Can you blow air through it? No The line is clogged. Yes Run a cable through the line to clear clogs.
CB GRN BLK Circuit Breaker 5 AMP BLK BLU Amp Connector 1 2 1 2 BLK WHT#2 ORG BLK BLK T8 T4 T5 T3 T2 T1 Motor 230V Filter Circuit 230V Filter Circuit WHT COM PUR NO NC RED YEL PUR RED YEL#1 WHT YEL YEL#1 BLU BLK COM NO NC RED BLK BLK ORG Shown in OFF Position 33.
Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-551-8633 (Tech Support) 1-318-219-7135 Price: $6.