Datasheet

80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
YES
V
alue Units
100-240 Volts
6 Amps
60-50 Hz
460 Watts
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz. Input AC Current Waveform (ITHD = 7.54%, 50% Load)
I
RMS
PF
A
-12
V
3.3
V
5V* 5VSB
0.98 0.99 5.3% 20%
Light
111 11.9/0.1 3.3/3.2 5/2.9 5.1/0.5 92
82.71%
2.37 0.99 7.5% 50%
Typical
271 11.9/0.2 3.2/7.9 5/7.2 5/1.2 230
84.61%
4.86 1.00 4.7% 100%
Full
558 12/0.5 3.2/15.7 5/14.4 4.9/2.5 455
81.58%
Tested by Electric Power Research Institute, Knoxville, TN.
84.61%
82.97%
FSP
FSP460-60PFB
NA
2007
Manufacturer
Test Date
Input Frequency
291
Type
Ecos ID #
Model Number
Serial Number
Year
ATX12V
Input
Watts
Fraction
of Load
DC Terminal Voltage (V)/ DC Load Current (A)
Output
Watts
12V (cumulative of 12V1, 12V2, etc.)
12/5.3
12/13.3
11.9/26.5
7/6/2007
Efficiency
%
Rated Output Power
Load
(%)
Rated Specifications
Input Voltage
Input Current
I
THD
(%)
Input and Output Power
Input Watts
Output Watts
0
100
200
300
400
500
600
20% 50% 100%
Loading (% of Rated Output Power)
Power (Watts)
Efficiency of the Power Supply
30%
40%
50%
60%
70%
80%
90%
0% 25% 50% 75% 100% 125%
Loading (% of Rated Output Power)
Efficiency (%)
Efficiency %
These tests were conducted as a part of the 80 PLUS program. 80 PLUS is
a computer buy-down program to promote high-efficiency power supplies
(greater than 80% efficiency in the active mode) in desktop computers and
desktop-derived servers.
Input Current and Voltage Waveforms
-200
-150
-100
-50
0
50
100
150
200
0 0.003 0.006 0.009 0.012 0.015
Time (s)
Voltage (V)
-15
-10
-5
0
5
10
15
Current (A)
Voltage Current

Summary of content (1 pages)