User`s manual

User’s manual · TSF 310 CI
- 5 - TSF 310 CI version_en_2.0 FTE maximal
If you have a module with a serial number higher than
075511441882 it will allow you to choose between two
units with an only device connected to the programmer
(Unit 1 or Unit 2.)
2. Device Status
In the option “Device Status” are specified the main parameters of the module at this moment.
- Front End: It indicates whether the module is hooked or without signal.
- Input bit rate: Transfers of data in the satellite tuner input.
- Output bit rate: Transfer of data in the module output.
- BER before and after Viterbi: It indicates the error rate of bits of the input
signal before and after the correction produced by Viterbi algorithm.
- MER: Parameter that indicates the quality of the input modulated digital signal,
expressed in dB.
- Noise Margin: It indicates the difference between the value of current C/N
and the value of C/N at the point of pixilation of the signal, that is, the quantity
of dBs of C/N measure that are needed to lose the input signal.
-Temperature: It indicates the current temperature of the module in ºC.
3. Set Front End
In this option you will be able to configure the input parameters of the satellite signal:
- Local oscillator: Selection of the local oscillator that you wish to use: FI, KU, C,
K9750, K10000, K10600, K10700, K10750, K11250, K11300, K11325.
- Frequency (MHz): Transponder frequency that you wish to tune.
- Symbol speed: Symbol speed required by the transponder.
- Auto symbol rate: You will be able to select if the detection of the Symbol
Rate is going to be Automatic (On) or Manual (Off).
- In Manual mode (Off), the value of the Symbol Rate should be fixed
by the user based on the provider’s information.
- In Automatic mode (On), the meter will automatically identify the SR
when a Satellite carrier is tuned. This feature is very useful when the
provider’s information is unknown.
The SR value found will appear in the field of selection of the SR menu. This value found by the meter could not
correspond exactly to the real broadcast SR, but to a very close value.
Note: The Automatic Symbol Rate feature does not work when the
carrier quality is very poor or/and with a very low Power Level.
- DVB: This option allows selecting the standard DVB of the transponder that
you want to tune. Options:DVB-S1,DVB-S2 and auto.
- LNB Supply: In this option you can set the parameters concerning the LNB:
- RF IN Voltage: 13V, 18V and Off.
- 22 kHz Tone: Off, On and Auto.
- DiseqC Switch: A, B, C, D and Off.