5−1 Common Correlation Detection Method
⑪ Press the menu switch
.
⑫ Tap “Leak location screen” to switch from
the FFT display to the leak location screen.
⑬ Verify that the pre-amplifier icon is lit, and
then press the Setting piping conditions
switch
.
⑭ Set the material, diameter, length, etc.
For details on configuring the pipe
conditions, see "Setting piping conditions"
under "4-7 Explanation of Equipment
Settings and Operations" on p. 38.
The pipe information can be set later if
necessary. Suspend correlation processing,
set the pipe information, and then restart
correlation processing. It is also possible to
reset the pipe information after saving it. The
saved data other than the pipe information
cannot be modified.
⑮ Verify that the pre-amplifier icon on the
main unit is lit, and then press the correlation
switch
.
⑯ Correlation processing starts and the screen
is updated.
The number next to the SD card icon is the
number of additions.
⑰ Press the correlation switch
to stop
correlation processing.
For details on saving the data, see "Saving
Correlation Data" under "4-7 Explanation of
Equipment Settings and Operations" on
p. 47.