User Guide Hand-held Barcode Scanner NLS-HR15 Fujian Newland Auto-ID Tech Co., Ltd.
Disclaimer © 2013 Fujian Newland Auto-ID Tech. Co., Ltd. All rights reserved. Please read through the manual carefully before using the product and operate it according to the manual. It is advised that you should keep this manual for future reference. Do not disassemble the device or remove the seal label from the device. Otherwise, FuJian Newland Auto-ID Tech. Co., Ltd. does not assume responsibility for the warranty or replacement.
Revision History Version Description Date V1.0 Initial release. December 25, 2011 V1.1 Corrected improper descriptions and moved the Enter/Exit Setup barcodes to page header and footer. August 10, 2012 Updates: 1. Added the “Pairing Settings” section in Chapter 2; added the Timeout between Decodes (Same Barcode) programming feature for the Sense and Continuous modes. V1.2 2. Added the “Improve Reliability of Communication between Cradle and PC” section in Chapter 4. 3.
Table of Contents Revision History .................................................................................................................................................................... - 3 Preface ........................................................................................................................................................................................1 Introduction .....................................................................................................
Use of Programming Barcodes.........................................................................................................................................19 Use of Command..............................................................................................................................................................20 Programming Mode.................................................................................................................................................
Flow Control ............................................................................................................................................................48 Data Bit ...................................................................................................................................................................49 USB Interface .......................................................................................................................................................
Set Length Range for UCC/EAN-128 ......................................................................................................................65 AIM 128 ............................................................................................................................................................................66 Restore Default Settings .........................................................................................................................................
UPC-E Extension ....................................................................................................................................................86 UPC-A ..............................................................................................................................................................................87 Restore Default Settings .........................................................................................................................................
Set Length Range for Matrix 2 of 5 ....................................................................................................................... 111 Industrial 25 .................................................................................................................................................................... 112 Restore Default Settings .......................................................................................................................................
Parity Check .......................................................................................................................................................... 136 Set Length Range for Code 11 .............................................................................................................................. 137 Plessey ...........................................................................................................................................................................
Preface Introduction This manual provides detailed instructions for setting up and using the NLS-HR15 series cordless 1D barcode scanner NLS-HR1550-3E (hereinafter referred to as “NLS-HR15 Hand-held Barcode Scanner” or “the scanner”). Chapter Description Chapter 1,Getting Started : This chapter gives a general description of NLS-HR15 Hand-held Barcode Scanner including its technical parameters.
Document Set The documentation set for the NLS-NLS-HR15 Hand-held Barcode Scanner provides information for specific user needs and includes: NLS-HR1550-3E Quick Start Guide Describes how to get the NLS-HR15 Hand-held Barcode Scanner up and running, and introduces some basic operations. NLS-HR1550-3E User Guide Describes how to use and set the NLS-HR15 Hand-held Barcode Scanner.
**【Enter Setup】 Chapter 1 Getting Started Introduction NLS-HR15 Hand-held Barcode Scanner is a 1D barcode scanner with excellent performance. Besides all common 1D symbologies, it can also read 2D stacked symbologies such as PDF417 and MicroPDF417. Based on the technology independently developed by Newland, NLS-HR15 Hand-held Barcode Scanner is able to deliver rapid image acquisition and accurate decoding; it can provide customers with best services.
**【Enter Setup】 Unpacking Open the package and take out NLS-HR15 Hand-held Barcode Scanner and its accessories. Check to make sure everything on the packing list is present and intact. If any contents are damaged or missing, please keep the original package and contact your dealer immediately for after-sale service. *Note: CD15, the cradle of NLS-HR15 Hand-held Barcode Scanner is individually wrapped. Scanner Decode/Transmission LED Definitions: Green Flash : Barcode decoded successfully.
**【Enter Setup】 CD15 Cradle Buttons: P:Batch Transmission M:Pair/Search LEDs: Zigbee LED (blue): Zigbee is available. Battery LED (green): Indicates battery level (four levels) Fig.
**【Enter Setup】 Fig. 1-3 Communication Mode There are three communication modes: synchronous mode (default), asynchronous mode and batch mode. Synchronous mode: If Zigbee is available, scanned data will be transferred to the cradle immediately after successfully decoded; if Zigbee is unavailable, the transmission of decoded data cannot be accomplished.
**【Enter Setup】 CD15 Data Port Fig. 1-5 Fig.
**【Enter Setup】 USB/RS-232 Port CD15 cradle must be connected to a Host in actual application, such as PC, POS or any intelligent terminal with USB or RS-232 port, via a communication cable, either USB or RS-232 cable. USB USB port on the Host RS-232 RS-232 port on the Host Note: Please check the port on the Host and purchase the right cable.
**【Enter Setup】 Connect Cradle to a Host Use USB Cable Fig. 1-6 Connect the CD15 cradle to a Host through a USB cable with RJ45 and USB connectors: 9 1. Plug the RJ45 connector into the data port (see Fig.1-3) on CD15 cradle. 2. Plug the USB connector into the USB port on the Host.
**【Enter Setup】 Use RS-232 Cable Fig. 1-7 Connect the CD15 cradle to a Host through a RS-232 cable with RJ45 and RS-232 connectors: 1. Plug the RJ45 connector into the data port (see Fig.1-3) on CD15 cradle. 2. Plug the RS-232 connector into the RS-232 port on the Host. 3. Plug the supplied power adapter into the power port (see Fig.1-3) on CD15 cradle.
**【Enter Setup】 Power on, Sleep, Power off, Reboot Powering on the device Hold down the trigger on the scanner for 1 second or longer. Note: When using the scanner for the first time, the user MUST hold down the trigger for 10-15 seconds to exit battery protection mode and activate the scanner. The scanner emits several beeps to indicate success.
**【Enter Setup】 Depth of Field Fig.
**【Enter Setup】 Specifications Performance Light Source 620nm visible red LED Image Sensor CCD linear image sensor Symbologies Code128, EAN-13, EAN-8, Code 39,UPC-A, UPC-E, Codabar, Interleaved 2 of 5, ISBN, Code 93, UCC/EAN-128, GS1 Databar, PDF417 (max. 255 bytes), MicroPDF417 (max. 255 bytes), etc. ≥ 4mil Resolution Scan Angle** Pitch ±55° Roll ±30° Skew ±75° Minimum Symbol Contrast 30% Scan Rate 300 scans per second Interface RS-232, USB 1.
**【Enter Setup】 **Test conditions: Code 39, 3 Bytes; Narrow Space=10mil; Width:Narrow=2.5:1; PCS=0.8; Barcode Height=40mm; Scan Distance=210mm, Ambient Temperature=23℃, Illumination= 200 LUX Dimensions of Scanner Side View Fig. 1-9 Front View Fig.
**【Enter Setup】 Top View Fig. 1-11 Dimensions of CD15 Cradle Fig.
**【Enter Setup】 Scanning Instructions When the NLS-HR15 Hand-held Barcode Scanner is in the Manual mode (default), you can follow the steps below to scan a barcode: 1. Hold down the trigger. Then the scanner will project a red aiming beam. 2. Aim the red beam across the center of barcode, as shown in Fig.1-13. 3. Release the trigger when the scanner beeps and the red beam goes off. If the barcode is decoded successfully, the data will be sent to the Host.
**【Enter Setup】 Scan Angle The scanner is designed to function within a certain range of scan angles. Any unreasonable deviation may cause decoding failure. Scan angles of the HR15: Pitch :±55°, 0° Roll and 0° Skew (Fig. 1-14) Roll :±30°, 0° Pitch and 0° Skew (Fig. 1-15) Skew:±75°, 0° Roll and 0° Pitch (Fig. 1-16) Fig. 1-14 Fig. 1-15 Fig.
**【Enter Setup】 Chapter 2 General Settings Introduction There are two ways to configure the NLS-HR15 Hand-held Barcode Scanner: barcode programming and command programming. Barcode Programming The NLS-HR15 Hand-held Barcode Scanner scans a series of barcodes to program features. In the following sections, we will explain the available options and features and provide the barcodes to program them. This programming method is most straightforward. However, it requires manually scanning barcodes.
**【Enter Setup】 Programming Barcode/ Programming Command/Function 1 2 4 3 The figure above is an example that shows you the programming barcode and command for the Enter Setup function: 1. The Enter Setup barcode. 2. The Enter Setup command. 3. The function that can be enabled by using the programming barcode or command listed above. 4. ** incidates factory default settings. Use of Programming Barcodes Scanning the Enter Setup barcode can enable the scanner to enter the setup mode.
**【Enter Setup】 Use of Command Based on serial port communication, programming commands can be composed of printable ASCII characters, 0x20 (space) through 0x7D (“}”). Programming Mode Before configuring the NLS-HR15 Hand-held Barcode Scanner through serial communication, the device must enter the programming mode; in such mode, the device will only accept and process commands and respond accordingly. You can enable the device to enter or exit the programming mode by sending the specified commands to it.
**【Enter Setup】 8. If a command involves parameter(s), they shall be combined as per the rule. For example: The combined commands for appending terminating character suffix 0x0D (CR),0x0A (LF) to the scanned data and saving the settings: “#99904112;#99900000;#99900015;#99900000;#99900012;#99900020;”.
**【Enter Setup】 Configuration Process Flow 【Exit Setup】 22
**【Enter Setup】 Default Settings Restore Factory Default Settings Scanning the Reset Scanner barcode/the Reset Cradle barcode can restore the scanner/cradle to the factory default settings. You may need to reset your scanner/cradle when: 1. scanner/cradle is not properly configured so that it fails to decode barcodes or to communicate with cradle; 2. you forget previous configuration and want to avoid its impact; 3. functions that are rarely used have been enabled for the time being.
**【Enter Setup】 Pairing Settings Pair Scanner with Cradle The scanner and cradle must be paired for communication to occur. A cradle can be paired with multiple scanners. You need to perform this operation manually: After the scanner and cradle are powered on, insert the scanner in the cradle and then press the “M” button on the cradle. Note: The number of scanners allowed to pair with a cradle varies from one application to another. Consult our technical support if you need more information.
**【Enter Setup】 Operating Mode Options 【Power Off】 1 【Test Mode 】 【Reboot Scanner】 【Reboot Cradle】 1 Note : Pressing the trigger on the scanner or rebooting the device can exit the Test mode.
**【Enter Setup】 Power-Off Timeout The NLS-HR15 Hand-held Barcode Scanner that stays in the sleep mode will be automatically powered off when the timeout occurs (default: 5 minutes). Scan the barcode below to set this parameter.
**【Enter Setup】 Scan Mode Manual Mode Manual Mode (default): A trigger pull activates a decode session. The decode session continues until the barcode is decoded or you release the trigger or the decode session timeout occurs (default: 15 seconds; programmable). **【Manual Mode】 Decode Session Timeout: This parameter sets the maximum time decode session continues during a scan attempt. The default timeout is 15s. To program this parameter, scan the Decode Session Timeout barcode and the numeric barcodes.
**【Enter Setup】 Auto Mode Auto Mode: Pressing the trigger activates a decode session. The decode session continues until the barcode is decoded or the decode session timeout occurs (default: 15 seconds; programmable). The scanner automatically starts one session after another until you press the trigger a second time.
**【Enter Setup】 Decode Session Timeout: This parameter sets the maximum time decode session continues during a scan attempt. The default timeout is 15s. To program this parameter, scan the Decode Session Timeout barcode and the numeric barcodes. To find the numeric barcodes, see the “Digit Barcodes” section in Chapter 7. Note: Decode Session Timeout: 01-15, corresponding to 1s, 2s, ……, 15s (default), in 1s increments; 00: infinite. You can also configure whether to allow rereading same barcode.
**【Enter Setup】 Blink Mode Blink Mode: The scanner automatically activates a decode session. The decode session continues until the barcode is decoded or the decode session timeout occurs (100ms; non-programmable). When a decode session is completed, the scanner waits until the timeout between decodes occurs (default: 1s, programmable) and then starts next session. The scanner continues to work in this pattern.
**【Enter Setup】 Sense Mode Sense Mode: The scanner activates a decode session every time when it detects a change in ambient illumination (excluding the situation when change is detected before the timeout between decodes occurs). Decode session continues until the barcode is decoded or the decode session timeout occurs. Pressing the trigger can also activate a decode session. Holding down the trigger can suspend decode session.
**【Enter Setup】 Sensitivity specifies the degree of acuteness of the scanner’s response to changes in ambient illumination. The higher the sensitivity, the lower requirement in illumination change to trigger the scanner. You can select an appropriate degree of sensitivity that fits the ambient environment. By default, High Sensitivity is enabled.
**【Enter Setup】 Timeout between Decodes (Same Barcode): This parameter sets the minimum time between decodes for the same barcode. It protects against accidental rereads of the same barcode. It is programmable in 0.1s increments from 0s to 12s. If you want to stop the scanner from rereading the same barcode, set this parameter to 127. The default timeout is 1.6s. To program this parameter, scan the Timeout between Decodes (Same Barcode) barcode, the numeric barcode(s) and the Save barcode.
**【Enter Setup】 Continuous Mode Continuous Mode: The scanner automatically activates a decode session. The decode session continues until the barcode is decoded. When a decode session is completed, the scanner waits until the timeout between decodes occurs and then starts next session. The scanner continues to work in this pattern. Same barcode cannot be reread before the timeout between decodes (same barcode) occurs.
**【Enter Setup】 Timeout between Decodes: This parameter sets the time period between the end of one decode session and the start of next session. It is programmable in 0.5s increments from 0s to 7.5s. The default timeout is 1s. To program this parameter, scan the Timeout between Decodes barcode and the numeric barcodes. Note: Timeout between Decodes: 00-15, corresponding to 0s, 0.5s, 1s (default), ……, 7.5s, in 0.5s increments.
**【Enter Setup】 Delayed Sense Mode Delayed Sense Mode: The scanner automatically activates a decode session when it detects a change in ambient illumination. The decode session continues until the barcode is decoded or the decode session timeout occurs. When a decode session is completed, the scanner waits 200ms and then starts to monitor ambient environment until it detects a change to trigger next decode session. Same barcode cannot be reread before the timeout between decodes (same barcode) occurs.
**【Enter Setup】 Security Setup This parameter specifies the number of times to decode a barcode during a scan attempt. The higher the security level, the lower the error rate and decoding efficiency. By default, security is set to be level 1.
**【Enter Setup】 Decode Beep By default, the scanner emits a medium-pitched loud beep that lasts 150ms after good decode.
**【Enter Setup】 **【Set Beep Length to 150ms】 【Set Beep Length to 50ms】 【Set Beep Length to 100ms】 39 【Exit Setup】
**【Enter Setup】 Decode Area and Output Interval You can set the number of barcodes allowed to be read per scan. By default, the Read One Barcode Nearest to the Center Per Scan option is enabled. You can also set the decoded data output interval. By default, output interval is 0ms.
**【Enter Setup】 Other Settings Temporary Mute 【Enable Temporary Mute】 【Disable Temporary Mute】 Note: Temporary Mute is only applicable to decode beep and will be disabled after you reboot the scanner.
**【Enter Setup】 Chapter 3 Inquiry Command Introduction This chapter provides programming barcodes you may need to obtain device information. Obtain Scanner Information You can scan one of the barcodes below to inquire the scanner information. The results will be sent to the Host.
**【Enter Setup】 Obtain Cradle Information You can scan one of the barcodes below to inquire the information about CD15 Cradle. The results will be sent to the Host.
**【Enter Setup】 Obtain Wireless Module Information You can scan one of the barcodes below to inquire the information about wireless module. The results will be sent to the Host. 【Inquire the Number Barcodes in Flash Memory】 【Delete All Barcodes in Flash Memory】 【Inquire the Wireless Module Status】 Note: Inquire the Wireless Module Status: Inquire wireless connection status and communication mode.
**【Enter Setup】 Chapter 4 Communication Settings Introduction Three types of wireless communication between scanner and cradle: synchronous, asynchronous and batch modes. Two types of wired communication between cradle and the Host: RS-232 and USB. Wireless Communication Setup Wireless communication modes include Synchronous (default), Asynchronous and Batch modes.
**【Enter Setup】 RS-232 Interface Baud Rate When the CD15 cradle is connected to the Host via serial port, you need to set communication parameters (including baud rate, parity check, data bit and stop bit) to match the host device. Baud rate is the number of bits of data transmitted per second. Set the cradle’s baud rate to match the Host requirements. Otherwise, data may not reach the Host or may reach it in distorted form. The default baud rate is 115200.
**【Enter Setup】 Parity Check By default, the None option is enabled. **【None】 【Even】 【Odd】 Stop Bit By default, the 1 Stop Bit option is enabled.
**【Enter Setup】 Flow Control By default, the No Flow Control option is enabled.
**【Enter Setup】 Data Bit By default, the 8 Data Bits option is enabled.
**【Enter Setup】 USB Interface By default, the USB HID-KBW option is enabled.
**【Enter Setup】 Keyboard Parameters Keyboard Layout By default, the 1-US (English) option is enabled ** 【1 – US (English)】 【7 - Italy】 【2 - Japanese】 【8 - Norway】 【3 - Denmark】 【9 - Spain】 【4 - Finland】 【10 - Turkey Q】 【5 - France】 【11 - UK】 51 【Exit Setup】
**【Enter Setup】 Inter-Character Delay Inter-character Delay: 00-15 (16 levels), corresponding to 0ms (default), 5ms, 10ms, …, 75ms, in 5ms increments. 【Inter-Character Delay】 Convert Case By default, the No Case Conversion option is enabled.
**【Enter Setup】 Improve Reliability of Communication between Cradle and PC There are three options available for users to choose for data communication between CD15 cradle and PC: USB HIDKBW, USB COM Port Emulation and RS-232 serial port. For USB HID-KBW, the hardware design ensures that barcode data is reliably sent to PC. Even if the cable is accidentally removed, the scanner will emit a specific beep to indicate transmission failure.
**【Enter Setup】 Chapter 5 Data Formatting Introduction After a successful barcode reading, a string containing numbers, letters or symbols will be returned. In real applications, barcode data may be found insufficient for your needs. You may wish to include additional information such as barcode type, data acquisition time or delimiter in data being scanned.
**【Enter Setup】 Custom Prefix Enable/Disable Custom Prefix If custom prefix is enabled, you are allowed to append to the data a user-defined prefix that cannot exceed 11 characters. By default, custom prefix is disabled. For example, if barcode data is “123” and custom prefix is “AB”, the Host will receive “AB123”.
**【Enter Setup】 6.Scan the Exit Setup barcode. AIM ID Prefix AIM (Automatic Identification Manufacturers) ID defines symbology identifier (For the details, see the “AIM ID Table” section in Chapter 7). If AIM ID prefix is enabled, the scanner will add the symbology identifier before the scanned data after decoding. By default, AIM ID prefix is disabled. **【Disable AIM ID Prefix】 【Enable AIM ID Prefix】 Code ID Prefix Code ID can also be used to identify barcode type.
**【Enter Setup】 Custom Suffix Enable/Disable Custom Suffix If custom suffix is enabled, you are allowed to append to the data a user-defined suffix that cannot exceed 11 characters. By default, custom suffix is disabled. For example, if barcode data is “123” and custom suffix is “AB”, the Host will receive “123AB”.
**【Enter Setup】 5.Scan the Enable Custom Suffix barcode. 6.Scan the Exit Setup barcode. Terminating Character Suffix Enable/Disable Terminating Character Suffix A terminating character such as carriage return (CR) or carriage return/line feed pair (CRLF) can only be used to mark the end of data, which means nothing can be added after it. By default, terminating character suffix is enabled.
**【Enter Setup】 Set Terminating Character Suffix To set a terminating character suffix, scan the Set Terminating Character Suffix barcode, the numeric barcodes corresponding to the hexadecimal value of a desired terminating character and the Save barcode. By default, terminating character 0x0D,0x0A is enabled. 【Set Terminating Character Suffix】 【Terminating Character 0x0D】 【Terminating Character 0x0D,0x0A】 Example: Set the terminating character to “0x0A” 1.Scan the Enter Setup barcode. 2.
**【Enter Setup】 Chapter 6 Symbologies Introduction Every symbology (barcode type) has its own unique attributes. This chapter provides programming barcodes for configuring the scanner so that it can identify various barcode symbologies. It is recommended to disable those that are rarely used to increase the efficiency of the scanner. Code 128 Restore Default Settings Scan the barcode below to restore all parameters in Code 128 configuration to the factory default settings.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Code 128. To set the Code ID, scan the Set Code ID for Code 128 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Code 128】 Example: Set the Code ID of Code 128 to “p” (its hexadecimal value is 0x70) 1.Scan the Enter Setup barcode. 2.
**【Enter Setup】 Set Length Range for Code 128 The scanner can be configured to only decode Code 128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 1 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Code 128 barcodes with either the minimum or maximum length.
**【Enter Setup】 UCC/EAN-128 Restore Default Settings Scan the barcode below to restore all parameters in UCC/EAN-128 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of UCC/EAN-128】 Enable/Disable UCC/EAN-128 UCC/EAN-128 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for UCC/EAN-128. To set the Code ID, scan the Set Code ID for UCC/EAN-128 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for UCC/EAN-128】 Example: Set the Code ID of UCC/EAN-128 to “p” (its hexadecimal value is 0x70) 1.Scan the Enter Setup barcode. 2.
**【Enter Setup】 Set Length Range for UCC/EAN-128 The scanner can be configured to only decode UCC/EAN-128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 1 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes UCC/EAN-128 barcodes with either the minimum or maximum length.
**【Enter Setup】 AIM 128 Restore Default Settings Scan the barcode below to restore all parameters in AIM 128 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of AIM 128】 Enable/Disable AIM 128 AIM 128 is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for AIM 128. To set the Code ID, scan the Set Code ID for AIM 128 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for AIM 128】 Example: Set the Code ID of AIM-128 to “p” (its hexadecimal value is 0x70) 1.Scan the Enter Setup barcode. 2.Scan the Set Code ID for AIM-128 barcode. 3.
**【Enter Setup】 Set Length Range for AIM 128 The scanner can be configured to only decode AIM 128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 1 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes AIM 128 barcodes with either the minimum or maximum length.
**【Enter Setup】 EAN-8 Restore Default Settings Scan the barcode below to restore all parameters in EAN-8 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of EAN-8】 Enable/Disable EAN-8 EAN-8 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for EAN-8. To set the Code ID, scan the Set Code ID for EAN-8 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for EAN-8】 Example: Set the Code ID of EAN-8 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for EAN-8 barcode. 3.
**【Enter Setup】 2-Digit Add-On Code An EAN-8 barcode can be augmented with a two-digit add-on code to form a new one.. **【Disable 2-Digit Add-On Code】 【Enable 2-Digit Add-On Code】 【Decode EAN-8 + 2-Digit Add-On Code Only】 Note: Disable 2-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard EAN-8 barcodes. Enable 2-Digit Add-On Code: The scanner decodes a mix of EAN-8 barcodes with and without 2-digit add-on codes.
**【Enter Setup】 5-Digit Add-On Code An EAN-8 barcode can be augmented with a five-digit add-on code to form a new one. **【Disable 5-Digit Add-On Code】 【Enable 5-Digit Add-On Code】 【Decode EAN-8 + 5-Digit Add-On Code Only】 Note: Disable 5-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard EAN-8 barcodes. Enable 5-Digit Add-On Code: The scanner decodes a mix of EAN-8 barcodes with and without 5-digit add-on codes.
**【Enter Setup】 EAN-8 Extension Disable EAN-8 Zero Extend: Transmit EAN-8 barcodes as is. Enable EAN-8 Zero Extend: Add five leading zeros to decoded EAN-8 barcodes to extend to13 digits. Convert EAN-8 to EAN-13: Add five leading zeros to decoded EAN-8 barcodes to make them compatible in format to EAN-13 barcodes.
**【Enter Setup】 EAN-13 Restore Default Settings Scan the barcode below to restore all parameters in EAN-13 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of EAN-13】 Enable/Disable EAN-13 EAN-13 is enabled by default.
**【Enter Setup】 Transmit Check Digit EAN-13 is 13 digits in length with the last one as its check digit used to verify the accuracy of the data. By default, the scanner transmits EAN-13 check digit. **【Transmit EAN-13 Check Digit】 【Do Not Transmit EAN-13 Check Digit】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for EAN-13.
**【Enter Setup】 5. Scan the Exit Setup barcode. 2-Digit Add-On Code An EAN-13 barcode can be augmented with a two-digit add-on code to form a new one. **【Disable 2-Digit Add-On Code】 【Enable 2-Digit Add-On Code】 【Decode EAN-13 + 2-Digit Supplement Only】 Note: Disable 2-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard EAN-13 barcodes.
**【Enter Setup】 5-Digit Add-On Code An EAN-13 barcode can be augmented with a five-digit add-on code to form a new one. **【Disable 5-Digit Add-On Code】 【Enable 5-Digit Add-On Code】 【Decode EAN-13 + 5-Digit Add-On Code Only】 Note: Disable 5-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard EAN-13 barcodes. Enable 5-Digit Add-On Code: The scanner decodes a mix of EAN-13 barcodes with and without 5-digit add-on codes.
**【Enter Setup】 ISSN Restore Default Settings Scan the barcode below to restore all parameters in ISSN configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of ISSN】 Enable/Disable ISSN ISSN is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for ISSN. To set the Code ID, scan the Set Code ID for ISSN barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for ISSN】 Example: Set the Code ID of ISSN to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for ISSN barcode. 3.
**【Enter Setup】 ISBN Restore Default Settings Scan the barcode below to restore all parameters in ISBN configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of ISBN】 Enable/Disable ISBN ISBN is disabled by default.
**【Enter Setup】 Set ISBN Format The default format is ISBN-13. **【ISBN-13】 【ISBN-10】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for ISBN. To set the Code ID, scan the Set Code ID for ISBN barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for ISBN】 Example: Set the Code ID of ISBN to “p” (its hexadecimal value is 0x70) 1.
**【Enter Setup】 5. Scan the Exit Setup barcode. UPC-E Restore Default Settings Scan the barcode below to restore all parameters in UPC-E configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of UPC-E】 Enable/Disable UPC-E UPC-E is enabled by default.
**【Enter Setup】 Transmit Check Digit UPC-E is 8 digits in length with the last one as its check digit used to verify the accuracy of the data. By default, the scanner transmits UPC-E check digit. **【Transmit UPC-E Check Digit】 【Do Not Transmit UPC-E Check Digit】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for UPC-E.
**【Enter Setup】 5. Scan the Exit Setup barcode. 2-Digit Add-On Code A UPC-E barcode can be augmented with a two-digit add-on code to form a new one. **【Disable 2-Digit Add-On Code】 【Enable 2-Digit Add-On Code】 【Decode UPC-E + 2-Digit Add-On Code Only】, Note: Disable 2-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard UPC-E barcodes.
**【Enter Setup】 5-Digit Add-On Code A UPC-E barcode can be augmented with a five-digit add-on code to form a new one. **【Disable 5-Digit Add-On Code】 【Enable 5-Digit Add-On Code】 【Decode UPC-E + 5-Digit Add-On Code Only】 Note: Disable 5-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard UPC-E barcodes. “Enable 5-Digit Add-On Code: The scanner decodes a mix of UPC-E barcodes with and without 5-digit add-on codes.
**【Enter Setup】 Transmit System Character “0” The first character of UPC-E barcode is the system character “0”. By default, the scanner does not transmit system character “0”. **【Do Not Transmit System Character “0”】 【Transmit System Character “0”】 UPC-E Extension Disable UPC-E Extend: Transmit UPC-E barcodes as is. Enable UPC-E Extend: Extend UPC-E barcodes to make them compatible in length to UPC-A. Convert UPC-E to UPC-A: Extend UPC-E barcodes to make them compatible in format to UPC-A.
**【Enter Setup】 UPC-A Restore Default Settings Scan the barcode below to restore all parameters in UPC-A configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of UPC-A】 Enable/Disable UPC-A UPC-A is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for UPC-A. To set the Code ID, scan the Set Code ID for UPC-A barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for UPC-A】 Example: Set the Code ID of UPC-A to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for UPC-A barcode. 3.
**【Enter Setup】 Transmit Check Digit UPC-A is 13 digits in length with the last one as its check digit used to verify the accuracy of the data. By default, the scanner transmits UPC-A check digit. **【Transmit UPC-A Check Digit】 【Do Not Transmit UPC-A Check Digit】 Transmit Preamble Character “0” The first character of UPC-A barcode is the preamble character “0”. By default, the scanner does not transmit preamble character “0”.
**【Enter Setup】 2-Digit Add-On Code A UPC-A barcode can be augmented with a two-digit add-on code to form a new one. **【Disable 2-Digit Add-On Code】 【Enable 2-Digit Add-On Code】 【Decode UPC-A + 2-Digit Add-On Code Only】, Note: Disable 2-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard UPC-A barcodes. Enable 2-Digit Add-On Code: The scanner decodes a mix of UPC-A barcodes with and without 2-digit add-on codes.
**【Enter Setup】 5-Digit Add-On Code A UPC-A barcode can be augmented with a five-digit add-on code to form a new one. **【Disable 5-Digit Add-On Code】 【Enable 5-Digit Add-On Code】 【Decode UPC-A + 5-Digit Add-On Code Only】 Note: Disable 5-Digit Add-On Code: The scanner only decodes the main part when scanning a new barcode. It can also decode standard UPC-A barcodes. Enable 5-Digit Add-On Code: The scanner decodes a mix of UPC-A barcodes with and without 5-digit add-on codes.
**【Enter Setup】 Interleaved 2 of 5 Restore Default Settings Scan the barcode below to restore all parameters in Interleaved 2 of 5 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Interleaved 2 of 5】 Enable/Disable Interleaved 2 of 5 Interleaved 2 of 5 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Interleaved 2 of 5. To set the Code ID, scan the Set Code ID for Interleaved 2 of 5 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Interleaved 2 of 5】 Example: Set the Code ID of Interleaved 2 of 5 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode.
**【Enter Setup】 Parity Check A check digit is optional for Interleaved 2 of 5 and can be added as the last digit. It is a calculated value used to verify the accuracy of the data. By default, the scanner does not transmit Interleaved 2 of 5 check digit after parity check. No Parity Check: The scanner transmits Interleaved 2 of 5 barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run a parity check using the last digit of Interleaved 2 of 5 barcode as check digit.
**【Enter Setup】 Set Length Range for Interleaved 2 of 5 The scanner can be configured to only decode Interleaved 2 of 5 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 5 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Interleaved 2 of 5 barcodes with either the minimum or maximum length.
**【Enter Setup】 ITF-6 ITF-6 is a special kind of Interleaved 2 of 5 with a length of 6 characters and the last character as the check character. By default, ITF-6 is disabled. ITF-6 priority principle: For the Interleaved 2 of 5 barcodes with a length of 6 characters and the last character as the check character, the ITF-6 configurations shall take precedence over the Interleaved 2 of 5 settings.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for ITF-6. To set the Code ID, scan the Set Code ID for ITF-6 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for ITF-6】 Example: Set the Code ID of ITF-6 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for ITF-6 barcode. 3.
**【Enter Setup】 ITF-14 ITF-14 is a special kind of Interleaved 2 of 5 with a length of 14 characters and the last character as the check character. By default, ITF-14 is disabled. ITF-14 priority principle: For the Interleaved 2 of 5 barcodes with a length of 14 characters and the last character as the check character, the ITF-14 configurations shall take precedence over the Interleaved 2 of 5 settings.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for ITF-14. To set the Code ID, scan the Set Code ID for ITF-14 barcode, the numeric barcodes for the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for ITF-14】 Example: Set the Code ID of ITF-14 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for ITF-14 barcode. 3.
**【Enter Setup】 Deutsche 14 Restore Default Settings Scan the barcode below to restore all parameters in Deutsche14 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Deutsche14】 Enable/Disable Deutsche14 Deutsche14 is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Deutsche14. To set the Code ID, scan the Set Code ID for Deutsche14 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Deutsche14】 Example: Set the Code ID of Deutsche14 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 Deutsche 12 Restore Default Settings Scan the barcode below to restore all parameters in Deutsche12 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Deutsche12】 Enable/Disable Deutsche 12 Deutsche12 is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Deutsche12. To set the Code ID, scan the Set Code ID for Deutsche 12 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Deutsche12】 Example: Set the Code ID of Deutsche12 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 COOP 25 (Japanese Matrix 2 of 5) Restore Default Settings Scan the barcode below to restore all parameters in COOP 25 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of COOP25】 Enable/Disable COOP 25 COOP 25 is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for COOP 25. To set the Code ID, scan the Set Code ID for COOP 25 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for COOP 25】 Example: Set the Code ID of COOP 25 to “p” (its hexadecimal value is 0x70). 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for COOP 25 barcode.
**【Enter Setup】 Parity Check A check digit is optional for COOP 25 and can be added as the last digit. It is a calculated value used to verify the accuracy of the data. By default, the scanner does not run parity check. No Parity Check: The scanner transmits COOP 25 barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run a parity check using the last digit of COOP 25 barcode as check digit.
**【Enter Setup】 Set Length Range for COOP 25 The scanner can be configured to only decode COOP 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 3 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes COOP 25 barcodes with either the minimum or maximum length.
**【Enter Setup】 Matrix 2 of 5 (European Matrix 2 of 5) Restore Default Settings Scan the barcode below to restore all parameters in Matrix 2 of 5 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Matrix 2 of 5】 Enable/Disable Matrix 2 of 5 Matrix 2 of 5 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Matrix 2 of 5. To set the Code ID, scan the Set Code ID for Matrix 2 of 5 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Matrix 2 of 5】 Example: Set the Code ID of Matrix 2 of 5 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 Parity Check A check digit is optional for Matrix 2 of 5 and can be added as the last digit. It is a calculated value used to verify the accuracy of the data. By default, the scanner does not run parity check. No Parity Check: The scanner transmits Matrix 2 of 5 barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run a parity check using the last digit of Matrix 2 of 5 barcode as check digit.
**【Enter Setup】 Set Length Range for Matrix 2 of 5 The scanner can be configured to only decode Matrix 2 of 5 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 3 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Matrix 2 of 5 barcodes with either the minimum or maximum length.
**【Enter Setup】 Industrial 25 Restore Default Settings Scan the barcode below to restore all parameters in Industrial 25 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Industrial 25】 Enable/Disable Industrial 25 Industrial 25 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Industrial 25. To set the Code ID, scan the Set Code ID for Industrial 25 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Industrial 25】 Example: Set the Code ID of Industrial 25 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 Parity Check A check digit is optional for Industrial 25 and can be added as the last digit. It is a calculated value used to verify the accuracy of the data. By default, the scanner transmits check digit after parity check. No Parity Check: The scanner transmits Industrial 25 barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run a parity check using the last digit of Industrial 25 barcode as check digit.
**【Enter Setup】 Set Length Range for Industrial 25 The scanner can be configured to only decode Industrial 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 4 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Industrial 25 barcodes with either the minimum or maximum length.
**【Enter Setup】 Standard 25 Restore Default Settings Scan the barcode below to restore all parameters in Standard 25 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Standard 25】 Enable/Disable Standard 25 Standard 25 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Standard 25. To set the Code ID, scan the Set Code ID for Standard 25 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Standard 25】 Example: Set the Code ID of Standard 25 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 Parity Check A check digit is optional for Standard 25 and can be added as the last digit. It is a calculated value used to verify the accuracy of the data. By default, the scanner does not run parity check. No Parity Check: The scanner transmits Standard 25 barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run a parity check using the last digit of Standard 25 barcode as check digit.
**【Enter Setup】 Set Length Range for Standard 25 The scanner can be configured to only decode Standard 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 4 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Standard 25 barcodes with either the minimum or maximum length.
**【Enter Setup】 Code 39 Restore Default Settings Scan the barcode below to restore all parameters in Code 39 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Code 39】 Enable/Disable Code 39 Code 39 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Code 39. To set the Code ID, scan the Set Code ID for Code 39 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Code 39】 Example: Set the Code ID of Code 39 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for Code 39 barcode.
**【Enter Setup】 Parity Check A check digit is optional for Code 39 and can be added as the last digit. It is a calculated value used to verify the accuracy of the data. By default, the scanner does not run parity check. No Parity Check: The scanner transmits Code 39 barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run a parity check using the last digit of Code 39 barcode as check digit.
**【Enter Setup】 Transmit Start/Stop Character Code 39 uses an asterisk (*) for both the start and the stop characters. You can choose whether or not to transmit the start/stop characters by scanning the appropriate barcode below. By default, the scanner transmits the start/stop characters. **【Transmit Start/Stop Character】 【Do not Transmit Start/Stop Character】 Enable/Disable Code 39 Full ASCII You can configure your scanner to identify all ASCII characters by scanning the appropriate barcode below.
**【Enter Setup】 Set Length Range for Code 39 The scanner can be configured to only decode Code 39 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 4 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Code 39 barcodes with either the minimum or maximum length.
**【Enter Setup】 Codabar Restore Default Settings Scan the barcode below to restore all parameters in Codabar configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Codabar】 Enable/Disable Codabar Codabar is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Codabar. To set the Code ID, scan the Set Code ID for Codabar barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Codabar】 Example: Set the Code ID of Codabar to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for Codabar barcode.
**【Enter Setup】 Parity Check A check digit is optional for Codabar and can be added as the last digit. It is a calculated value used to verify the accuracy of the data. By default, the scanner does not run parity check. No Parity Check: The scanner transmits Codabar barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run a parity check using the last digit of Codabar barcode as check digit.
**【Enter Setup】 Start/Stop Character By default, the scanner transmits start/stop characters which are in the form of “ABCD/ABCD”.
**【Enter Setup】 Set Length Range for Codabar The scanner can be configured to only decode Codabar barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 2 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Codabar barcodes with either the minimum or maximum length.
**【Enter Setup】 Code 93 Restore Default Settings Scan the barcode below to restore all parameters in Code 93 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Code 93】 Enable/Disable Code 93 Code 93 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Code 93. To set the Code ID, scan the Set Code ID for Code 93 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Code 93】 Example: Set the Code ID of Code 93 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for Code 93 barcode.
**【Enter Setup】 Parity Check Check digits are optional for Code 93 and can be added as the last two digits, which are calculated values used to verify the accuracy of the data. By default, the scanner does not transmit check digits after parity check. No Parity Check: The scanner transmits Code 93 barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run parity checks using the last two digit of Code 93 barcode as check digits.
**【Enter Setup】 Set Length Range for Code 93 The scanner can be configured to only decode Code 93 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 1 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Code 93 barcodes with either the minimum or maximum length.
**【Enter Setup】 Code 11 Restore Default Settings Scan the barcode below to restore all parameters in Code 11 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Code 11】 Enable/Disable Code 11 Code 11 is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Code 11. To set the Code ID, scan the Set Code ID for Code 11 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Code 11】 Example: Set the Code ID of Code 11 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for Code 11 barcode.
**【Enter Setup】 Parity Check Check digits are optional for Code 11 and can be added as the last one or two digits, which are calculated values used to verify the accuracy of the data. By default, the scanner does not transmit check digit after parity check (One Check Digit, MOD11). If the No Parity Check option is enabled, the scanner transmits Code 11 barcodes as is.
**【Enter Setup】 and the minimum length is set to 4, Code 11 barcodes with a total length of 4 characters including the check digit cannot be read.) Set Length Range for Code 11 The scanner can be configured to only decode Code 11 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 3 to 255 characters.
**【Enter Setup】 Plessey Restore Default Settings Scan the barcode below to restore all parameters in Plessey configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of Plessey】 Enable/Disable Plessey Plessey is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for Plessey. To set the Code ID, scan the Set Code ID for Plessey barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for Plessey】 Example: Set the Code ID of Plessey to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for Plessey barcode.
**【Enter Setup】 Parity Check Check digits are optional for Plessey and can be added as the last two digits, which are calculated values used to verify the accuracy of the data. By default, the scanner does not transmit check digits after parity check. No Parity Check: The scanner transmits Plessey barcodes as is. Do Not Transmit Check Digit After Parity Check: The scanner will run parity checks using the last two digits of Plessey barcode as check digits.
**【Enter Setup】 Set Length Range for Plessey The scanner can be configured to only decode Plessey barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 4 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes Plessey barcodes with either the minimum or maximum length.
**【Enter Setup】 MSI-Plessey Restore Default Settings Scan the barcode below to restore all parameters in MSI-Plessey configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of MSI-Plessey】 Enable/Disable MSI-Plessey MSI-Plessey is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for MSI-Plessey. To set the Code ID, scan the Set Code ID for MSI-Plessey barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for MSI-Plessey】 Example: Set the Code ID of MSI-Plessey to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 Parity Check Check digits are optional for MSI-Plessey and can be added as the last one or two digits, which are calculated values used to verify the accuracy of the data. By default, the scanner does not transmit check digit after parity check (One Check Digit, MOD10). If the No Parity Check option is enabled, the scanner transmits MSI-Plessey barcodes as is.
**【Enter Setup】 Set Length Range for MSI-Plessey The scanner can be configured to only decode MSI-Plessey barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 3 to 255 characters. If minimum length is set to be greater than maximum length, the scanner only decodes MSI-Plessey barcodes with either the minimum or maximum length.
**【Enter Setup】 GS1 Databar Restore Default Settings Scan the barcode below to restore all parameters in GS1 Databar configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of GS1 Databar】 Enable/Disable GS1 Databar GS1 Databar is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for GS1 Databar. To set the Code ID, scan the Set Code ID for GS1 Databar barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for GS1 Databar】 Example: Set the Code ID of GS1 Databar to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 PDF417 Restore Default Settings Scan the barcode below to restore all parameters in PDF417 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of PDF417】 Enable/Disable PDF417 PDF417 is enabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for PDF417. To set the Code ID, scan the Set Code ID for PDF417 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for PDF417】 Example: Set the Code ID of PDF417 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2. Scan the Set Code ID for PDF417 barcode. 3.
**【Enter Setup】 Set Length Range for PDF417 The scanner can be configured to only decode PDF417 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 1 to 255 bytes. If minimum length is set to be greater than maximum length, the scanner only decodes MSI-Plessey barcodes with either the minimum or maximum length.
**【Enter Setup】 Sample Barcodes When reading a PDF417 barcode, you need to scan it horizontally from the top/bottom row of the barcode to the bottom/top. Apart from the influence of barcode density, consecutive horizontal scans are essential for accomplishing a good read. The greater the row height is, the easier it is to decode a PDF417 barcode. Listed below are some sample barcodes (15 mil).
**【Enter Setup】 【abcdefghijklmnopqrstuvwxyz】 【Exit Setup】 152
**【Enter Setup】 MicroPDF417 Restore Default Settings Scan the barcode below to restore all parameters in PDF417 configuration to the factory default settings. To find the related default settings, see the “Default Parameters Table” section in Chapter 7. 【Restore the Default Settings of MicroPDF417】 Enable/Disable MicroPDF417 MicroPDF417 is disabled by default.
**【Enter Setup】 Set Code ID Code ID can only consist of one or two English letters. See the “Code ID Table” section in Chapter 7 to find the default Code ID for MicroPDF417. To set the Code ID, scan the Set Code ID for MicroPDF417 barcode, the numeric barcodes corresponding to the hexadecimal value of a desired ID and the Save barcode. 【Set Code ID for MicroPDF417】 Example: Set the Code ID of MicroPDF417 to “p” (its hexadecimal value is 0x70) 1. Scan the Enter Setup barcode. 2.
**【Enter Setup】 Set Length Range for MicroPDF417 The scanner can be configured to only decode MicroPDF417 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. Both lengths can range from 1 to 255 bytes. If minimum length is set to be greater than maximum length, the scanner only decodes MSI-Plessey barcodes with either the minimum or maximum length.
**【Enter Setup】 Sample Barcodes When reading a MicroPDF417 barcode, you need to scan it horizontally from the top/bottom row of the barcode to the bottom/top. Apart from the influence of barcode density, consecutive horizontal scans are essential for accomplishing a good read. The greater the row height is, the easier it is to decode a MicroPDF417 barcode. Listed below are some sample barcodes (15 mil).
**【Enter Setup】 【abcdefghijklmnopqrstuvwxyz】 157 【Exit Setup】
Chapter 7 Appendix Default Parameters Table Parameter Default Remark General Settings Setup Mode Enabled Scan Mode Manual Mode Wireless Communication Mode Synchronous Mode Decode Session Timeout 15 seconds 00~15 (00: Infinite; 01~15: 1~15sec) Timeout between Decodes 1 second 00~15 (0~7.
Parameter Default Inter-Character Delay 0ms Convert Case No Case Conversion Communication Support Disabled Remark 00-15(0-75ms) HR15PCWidget required Data Formatting Prefix Sequence Code ID+Custom+AIM ID AIM ID Prefix Disabled Code ID Prefix Disabled 1 or 2 English letters Custom Prefix Disabled Max. length: 11 characters Custom Suffix Disabled Max.
Parameter Default Remark EAN-13 EAN-13 Enabled Check Digit Transmit 2-Digit Add-On Code Disabled 5-Digit Add-On Code Disabled Decode EAN-13 + 2-digit Add-On Code Only Disabled Decode EAN-13 + 5-digit Add-On Code Only Disabled ISSN ISSN Disabled ISBN ISBN Disabled ISBN Format ISBN-13 UPC-E UPC-E Enabled Check Digit Transmit 2-Digit Add-On Code Disabled 5-Digit Add-On Code Disabled Decode UPC-E + 2-digit Add-On Code Only Disabled Decode UPC-E + 5-digit Add-On Code Only Disabled
Parameter Default Check Digit Do not transmit Maximum Length 255 Minimum Length 6 Remark Min. length supported: 5 ITF-6 ITF-6 Disabled Check Digit Do not transmit ITF-14 ITF-14 Disabled Check Digit Do not transmit Deutshe 14 Deutshe 14 Disabled Check Digit Do not transmit Deutshe 12 Deutshe 12 Disabled Check Digit Do not transmit COOP 25 (Japanese Matrix 2 of 5) COOP 25 Disabled Parity Check Disabled Check Digit Do not transmit Maximum Length 255 Minimum Length 6 Min.
Parameter Default Remark Standard 25 Standard 25 Enabled Parity Check Disabled Check Digit Do not transmit Maximum Length 255 Minimum Length 6 Min. length supported: 4 Code 39 Code 39 Enabled Parity Check Disabled Check Digit Do not transmit Start/Stop Character Transmit Code 39 Full ASCII Enabled Maximum Length 255 Minimum Length 4 Min.
Parameter Default Maximum Length 255 Minimum Length 4 Remark Min. length supported: 3 Plessey Plessey Disabled Parity Check Enabled Check Digit Do not transmit Maximum Length 255 Minimum Length 4 Min. length supported: 4 MSI-Plessey MSI-Plessey Disabled Check Digit Do not transmit Parity Check Enabled 1 Check Digit, MOD10 Maximum Length 255 Minimum Length 4 Min.
AIM ID Table Barcode Type AIM ID Code 128 ]C0 UCC/EAN-128 ]C1 AIM 128 ]C2 EAN-8 ]E4 EAN-13 ]E0 EAN-13 with Add-On ]E3 ISSN ]X0 Possible AIM ID Modifiers (m) ISBN ]X0 UPC-E ]E0 UPC-E with Add-On ]E3 UPC-A ]E0 UPC-A with Add-On ]E3 Interleaved 2 of 5 ]Im 0,1,3 ITF-6 ]Im 1,3 ITF-14 ]Im 1,3 Deutsche 14 ]X0 Deutsche 12 ]X0 COOP 25(Japanese Matrix 2 of 5) ]X0 Matrix 2 of 5(European Matrix 2 of 5) ]X0 Industrial 25 ]S0 Standard 25 ]R0 Code 39 ]Am 0,1,3,4,5,7 Codab
identification and data capture techniques – Data Carrier Identifiers (including Symbology Identifiers) for AIM modifier character details.
Code ID Table Barcode Type Code ID Code 128 j UCC/EAN-128 u AIM 128 f ISBT 128 t EAN-8 g EAN-13 d ISSN n ISBN B UPC-E h UPC-A c Interleaved 2 of 5 e ITF-6 r ITF-14 q Deutsche 14 w Deutsche 12 l COOP 25(Japanese Matrix 2 of 5) o Matrix 2 of 5(European Matrix 2 of 5) v Industrial 25 i Standard 25 s Code 39 b Codabar a Code 93 y Code 11 z Plessey p MSI-Plessey m GS1 Databar R PDF417 P MicroPDF417 M 166
Digit Barcodes After scanning numeric barcode(s), you need to scan the Save barcode on the next page to save the data.
A~F 【A】 【B】 【C】 【D】 【E】 【F】 168
Save/Cancel Barcodes After reading numeric barcode(s), you need to scan the Save barcode to save the data. If you scan the wrong digit(s), you can either scan the Cancel the Current Settings barcode and then start the configuration all over again, or scan the Delete the Last Digit barcode and then the correct digit, or scan the Delete All digits barcode and then the digits you want.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.