NLS-HR32 Hand-held Barcode Scanner User Guide
Disclaimer © 2013-2016 Fujian Newland Auto-ID Tech. Co., Ltd. All rights reserved. Please read through the manual carefully before using the product and operate it according to the manual. It is advised that you should keep this manual for future reference. Do not disassemble the device or remove the seal label from the device, doing so will void the product warranty provided by Fujian Newland Auto-ID Tech. Co., Ltd. All pictures in this manual are for reference only and actual product may differ.
Revision History Version V1.0.0 Description Initial release. Date June 26, 2013 Updates: V1.0.1 1. Added the Germany keyboard, Emulate Alt+Keypad, Function Key Mapping and Emulate Numeric Keypad features in Chapter 4. April 16, 2014 2. Added ASCII Function Key Mapping Table in Appendix. V1.0.2 Modified the default length range of Code 39, PDF417, QR Code and Data Matrix. March 27, 2015 Updates: V1.0.3 1. Deleted the EzSet123 Programming section in Chapter 2. May 12, 2015 2.
Table of Contents Revision History ........................................................................................................................................... - 3 Preface............................................................................................................................................................... 1 Introduction ............................................................................................................................................
Pairing Settings .................................................................................................................................... 19 Pair Scanner with Cradle ............................................................................................................... 19 Pair Cradle with Zigbee Router ..................................................................................................... 19 Search Paired Scanners.............................................................
Baud Rate ...................................................................................................................................... 38 Parity Check .................................................................................................................................. 39 Stop Bit .......................................................................................................................................... 39 Hareware Flow Control ............................................
Enable/Disable EAN-8 ................................................................................................................... 56 Transmit Check Digit ..................................................................................................................... 56 Add-On Code ................................................................................................................................. 57 Add-On Code Required ................................................................
Code 39................................................................................................................................................ 77 Restore Factory Defaults ............................................................................................................... 77 Enable/Disable Code 39 ................................................................................................................ 77 Transmit Start/Stop Character ................................................
Restore Factory Defaults ............................................................................................................... 97 Enable/Disable ISSN ..................................................................................................................... 97 Add-On Code ................................................................................................................................. 98 Add-On Code Required .................................................................
Restore Factory Defaults ............................................................................................................. 119 Enable/Disable Data Matrix ......................................................................................................... 119 Set Length Range for Data Matrix ............................................................................................... 120 Rectangular Barcode ...................................................................................
Preface Introduction This manual provides detailed instructions for setting up and using the NLS-HR3260 Series cordless 2D barcode scanner (hereinafter referred to as “HR32 cordless scanner” or “the scanner”). Chapter Description 1 Chapter 1, Getting Started Gives a general description of HR32 cordless scanner. Chapter 2, System Settings Introduces three configuration methods and describes how to configure general parameters of HR32 cordless scanner.
Explanation of Icons This icon indicates something relevant to this manual. This icon indicates this information requires extra attention from the reader. This icon indicates handy tips that can help you use or configure the scanner with ease. This icon indicates practical examples that can help you to acquaint yourself with operations.
Chapter 1 Getting Started Introduction The HR32 cordless scanner reads a 1D or 2D barcode by capturing its image. Adopting the advanced technology independently developed by Newland Auto-ID Tech, it provides users with three scan modes, including Manual Mode, Sense Mode and Continuous Mode, tailored to different scanning needs. An illustrated introduction to the HR32 cordless scanner is included in this chapter.
Scanner Logo Decode/Transmission LED Decode/Transmission LED: Scan Window Green: Barcode decoded successfully. Label Battery is fully charged. Trigger Blue: Zigbee is available. Red: Data transmission failed. Device is charging. Purple: Firmware update is in progress. There is data in FLASH memory. Reset Button Fig.
CD32 Cradle Buttons: P: Batch Transmission M: Pair/Search LEDs: Zigbee LED (blue): Zigbee is available. Batch Transmission Battery LEDs Pair/Search Zigbee LED Fig. 1-2 Power Port Data Port DIP Switch Fig.
Communication Mode Communication modes: synchronous mode (default), asynchronous mode and batch mode. Synchronous Mode: If Zigbee is available, scanned data will be transferred to the cradle immediately after a good read; if Zigbee is unavailable, the transmission of decoded data cannot be accomplished.
USB/RS-232 Port CD32 cradle must be connected to a Host in actual application, such as PC, POS or any intelligent terminal with USB or RS-232 port, via a communication cable, either USB or RS-232 cable. USB USB port on the Host RS-232 RS-232 port on the Host Note: Please check the port on the Host and purchase the right cable. Connecting Cradle to a Host Fig.
Use USB Cable Fig. 1-6 Connect the CD32 cradle to a Host through a USB cable with RJ45 and USB connectors: 1. Plug the RJ45 connector into the data port (see Fig.1-3) on the cradle. 2. Plug the USB connector into the USB port on the Host. 3. Plug the supplied power adapter into the power port (see Fig.1-3) on the cradle.
Use RS-232 Cable Fig. 1-7 Connect the CD32 cradle to a Host through an RS-232 cable with RJ45 and RS-232 connectors: 9 1. Plug the RJ45 connector into the data port (see Fig.1-3) on the cradle. 2. Plug the RS-232 connector into the RS-232 port on the Host. 3. Plug the supplied power adapter into the power port (see Fig.1-3) on the cradle.
Power On, Sleep, Power Off, Reboot Powering on the scanner Hold down the trigger on the scanner for 1 second or longer. Entering the sleep mode If no operation is performed on the scanner for 5 seconds, it will automatically enter the sleep mode. (Applicable to the Manual mode only) Powering off the scanner Scan the Power Off barcode.
Dimensions of Scanner Side View unit: mm Fig. 1-8 Front View unit: mm Fig. 1-9 Top View unit: mm Fig.
Dimensions of CD32 Cradle Fig.
Scanning Instructions When the scanner is in the Manual scan mode, you can follow the steps below to scan a barcode: 1. Press and hold the trigger. Then the scanner will project a red aiming beam. 2. Aim the red beam across the center of barcode, as shown in Fig.1-12. 3. Release the trigger when the red beam goes off. If the barcode is decoded successfully, the scanner will beep and the decoded data will be sent to the Host.
Scan Angle The scanner is designed to function within a certain range of scan angles. Any unreasonable deviation may cause decoding failure. Scan angles of the scanner: Pitch: ±55°, 0°Roll and 0°Skew (Fig. 1-13) Roll: 360°, 0 Pitch and 0°Skew (Fig. 1-14) Skew: ±55°, 0°Roll and 0°Pitch (Fig. 1-15) Fig. 1-13 Fig. 1-14 Fig.
【Enter Setup】 Chapter 2 System Settings Introduction There are two ways to configure the scanner: barcode programming and command programming. Barcode Programming The scanner can be configured through scanning programming barcodes. In the following sections, we will explain the available options and features and provide the barcodes to program them. This programming method is most straightforward. However, it requires manually scanning barcodes. As a result, errors are more likely to occur.
【Enter Setup】 Programming Barcode/Command/Function The figure above is an example that shows you the programming barcode and command for the Exit Setup function: 1. The Exit Setup barcode 2. The Exit Setup command 3. The function/feature that can be enabled by using the programming barcode or command listed above. 4. ** indicates factory default setting.
【Enter Setup】 Use of Programming Barcodes Scanning the Enter Setup barcode can enable the scanner to enter the setup mode. Then you can scan a number of programming barcodes to configure your scanner. To exit the setup mode, scan the Exit Setup barcode. After scanning the Exit Setup barcode, only some special programming barcodes, such as the Enter Setup barcode, can be read.
【Enter Setup】 Factory Defaults Scanning the Reset Scanner barcode/the Reset Cradle barcode can restore the scanner/cradle to the factory default settings. You may need to reset your scanner/cradle when: 1. scanner/cradle is not properly configured so that the scanner fails to decode barcodes or to communicate with cradle; 2. you forget previous configuration and want to avoid its impact; 3. functions that are rarely used have been enabled for the time being.
【Enter Setup】 Pairing Settings Pair Scanner with Cradle A cradle with its DIP switch (see Fig. 1-3) in the “C” position works as a normal cradle. The scanner and cradle must be paired for communication to occur. A cradle can be paired with multiple scanners. You need to perform this operation manually: After the scanner and cradle are powered on, insert the scanner in the cradle and then press the “M” button on the cradle. The scanner beeps on a successful pairing.
【Enter Setup】 Operating Mode Options 【Power Off】 【Reboot Scanner】 【Reboot Scanner】 **【Exit Setup】 20
【Enter Setup】 Power-Off Timeout Power-off timeout specifies the amount of time the scanner remains in sleep mode before it powers off automatically. Scan the barcode below to set this parameter.
【Enter Setup】 Illumination A couple of illumination options are provided to improve the lighting conditions during every image capture: Normal: Illumination LEDs are turned on only when scanner is reading barcode. Always ON: Illumination LEDs keep ON after scanner is powered on. OFF: Illumination LEDs are OFF all the time.
【Enter Setup】 Aiming When scanning/capturing image, the scanner projects an aiming pattern which allows positioning the target barcode within its field of view and thus makes decoding easier. Normal: The scanner projects an aiming pattern only during barcode scanning/capture. Always ON: Aiming pattern is constantly ON after the scanner is powered on. OFF: Aiming pattern is OFF all the time.
【Enter Setup】 Beep Good Read Beep Scan the appropriate barcode below to enable or disable the emission of beep when a non-programming barcode is decoded.
【Enter Setup】 Good Read Beep Volume **【Loud】 【Low】 【Medium】 Startup Beep **【Startup Beep On】 25 【Startup Beep Off】 **【Exit Setup】
【Enter Setup】 Transmit NGR Message Scan a barcode below to select whether or not to transmit a user-defined NGR (Not Good Read) message when a barcode is not decoded. 【Transmit NGR Message】 **【Do Not Transmit NGR Message】 Edit NGR Message To edit an NGR message, scan the Edit NGR Message barcode and the numeric barcodes corresponding to the ASCII values (decimal) of desired character(s) and then scan the Save barcode. An NGR message can contain 0-7 characters (ASCII value of character: 0-255).
【Enter Setup】 Scan Mode Manual Mode A trigger pull activates a decode session. The decode session continues until the barcode is decoded or you release the trigger or decode session timeout expires. **【Manual Mode】 Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt. It is programmable in 1ms increments from 1ms to 3,600,000ms. When it is set to 0, the timeout is infinite. The default setting is 3,000ms.
【Enter Setup】 Timeout between Decodes (Same Barcode) Timeout between Decodes (Same Barcode) can avoid undesired rereading of same barcode in a given period of time. To enable/disable the Timeout between Decodes (Same Barcode), scan the appropriate barcode below. Enable Timeout between Decodes: Do not allow the scanner to re-read same barcode before the timeout between decodes (same barcode) expires. Disable Timeout between Decodes: Allow the scanner to re-read same barcode.
【Enter Setup】 Sense Mode The scanner waits for the image stabilization timeout to expire before activating a decode session every time it detects a change in ambient illumination. Decode session continues until the barcode is decoded or the decode session timeout expires. In the Sense mode, a trigger pull can also activate a decode session. The decode session continues until the barcode is decoded or the trigger is released. When the session ends, the scanner continues to monitor ambient illumination.
【Enter Setup】 Image Stabilization Timeout The scanner waits for the image stabilization timeout to expire before activating a decode session every time it detects a change in ambient illumination. The image stabilization timeout is programmable in 1ms increments from 0ms to 1,600ms. The default setting is 500ms. 【Image Stabilization Timeout】 Set the Image Stabilization Timeout to 1,500ms: 1. Scan the Enter Setup barcode. 2. Scan the Image Stabilization Timeout barcode. 3.
【Enter Setup】 Timeout between Decodes (Same Barcode) Timeout between Decodes (Same Barcode) can avoid undesired rereading of same barcode in a given period of time. To enable/disable the Timeout between Decodes (Same Barcode), scan the appropriate barcode below. Enable Timeout between Decodes: Do not allow the scanner to re-read same barcode before the timeout between decodes (same barcode) expires. Disable Timeout between Decodes: Allow the scanner to re-read same barcode.
【Enter Setup】 Sensitivity Sensitivity specifies the degree of acuteness of the scanner’s response to changes in ambient illumination. The higher the sensitivity, the lower requirement in illumination change to trigger the scanner. You can select an appropriate degree of sensitivity that fits the ambient environment.
【Enter Setup】 Continuous Mode If the Continuous mode is enabled, the scanner automatically starts one decode session after another. To suspend/resume barcode reading, simply press the trigger. 【Continuous Mode】 Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt. It is programmable in 1ms increments from 1ms to 3,600,000ms. When it is set to 0, the timeout is infinite. The default setting is 3,000ms.
【Enter Setup】 Timeout between Decodes This parameter sets the timeout between decode sessions. When a decode session ends, next session will not happen until the timeout between decodes expires. It is programmable in 1ms increments from 0ms to 65,535ms. The default setting is 1,000ms. 【Timeout between Decodes】 Set the Timeout between Decodes to 1,500ms: **【Exit Setup】 1. Scan the Enter Setup barcode. 2. Scan the Timeout between Decodes barcode. 3. Scan the numeric barcodes “1”, “5”, “0” and “0”.
【Enter Setup】 Chapter 3 Inquiry Command Introduction This chapter provides programming barcodes you may need to obtain device information. Obtain Scanner Information You can scan the barcode below to inquire the scanner information (such as model number, serial number, manufacture date and firmware version). The result will be sent to the Host.
【Enter Setup】 Obtain FLASH Information To inquire the number of the barcodes stored in flash memory or empty the memory, scan the appropriate barcode below.
【Enter Setup】 Chapter 4 Communication Settings Introduction Three types of wireless communication between scanner and cradle: synchronous, asynchronous and batch modes. Two types of wired communication between cradle and the Host: RS-232 and USB. Wireless Communication Wireless communication modes include Synchronous (default), Asynchronous and Batch modes.
【Enter Setup】 RS-232 Interface Baud Rate When the CD32 cradle is connected to the Host via serial port, you need to set communication parameters (including baud rate, parity check, data bit and stop bit) to match the host device. Baud rate is the number of bits of data transmitted per second. Set the cradle’s baud rate to match the Host requirements. Otherwise, data may not reach the Host or may reach it in distorted form. The default baud rate is 115200.
【Enter Setup】 Parity Check By default, the None option is enabled. **【None】 【Even】 【Odd】 Stop Bit By default, the 1 Stop Bit option is enabled.
【Enter Setup】 Hareware Flow Control By default, the hardware flow control is disabled. **【Disable Hardware Flow Control】 【Enable Hardware Flow Control】 Before enabling hardware flow control, make sure that RTS/CTS signal line is contained in RS-232 cable. Without the signal line, RS-232 communication errors will occur. Data Bit 8 data bits are used and cannot be altered.
【Enter Setup】 USB Interface Two communication options are provided when the cradle is connected to the Host via USB interface: USB HID-KBW and USB COM Port Emulation USB HID-KBW **【USB HID-KBW】 Examine KBW Connection By default, the scanner examines whether KBW connection is available before data transmission by sending the Caps Lock key to the host device first.
【Enter Setup】 USB Country Keyboard Types Keyboard layouts vary from country to country. The default setting is U.S. keyboard. **【U.S.
【Enter Setup】 【Spain】 【Turkey Q】 【UK】 【Germany】 【Belgium】 【Russia】 【Sweden】 【Portugal】 43 **【Exit Setup】
【Enter Setup】 Inter-Keystroke Delay This parameter specifies the delay between emulated keystrokes.
【Enter Setup】 Convert Case Scan the appropriate barcode below to convert barcode data to your desired case. **【No Case Conversion】 【Convert All to Lower Case】 【Convert All to Upper Case】 【Invert Upper and Lower Case Characters】 When the Invert Upper and Lower Case Characters feature is enabled, barcode data “AbC” is transmitted as “aBc”.
【Enter Setup】 Emulate ALT+Keypad This feature allows any ASCII character (0x00 - 0xFF) to be sent over the numeric keypad no matter which keyboard type is selected. Since sending a character involves multiple keystroke emulations, this method appears less efficient. The following options are available: Disable: No ASCII character is sent in the ALT+Keypad way. Mode 1: ASCII characters not supported by the selected keyboard type but falling into 0x20~0xFF are sent in the ALT+Keypad way.
【Enter Setup】 Function Key Mapping When Function Key Mapping is enabled, function characters (0x00 - 0x1F) are sent as ASCII sequences over the keypad. For more information, see ASCII Function Key Mapping Table in Appendix.
【Enter Setup】 Emulate Numeric Keypad When this feature is disabled, sending barcode data is emulated as keystroke(s) on main keyboard. To enable this feature, scan the Emulate Numeric Keypad barcode. Sending a number (0-9) is emulated as keystroke(s) on numeric keypad, whereas sending other character like “+”, “_”, “*” , “/” and “.” is still emulated as keystrokes on main keyboard.
【Enter Setup】 USB COM Port Emulation To use this feature, a driver is required. 【USB COM Port Emulation】 USB HID-POS Introduction The USB HID-POS interface is recommended for new application programs. It can send up to 56 characters in a single USB report and appears more efficient than keyboard emulation. Features: HID based, no custom driver required. Way more efficient in communication than keyboard emulation and traditional RS-232 interface. Note: USB HID-POS does not require a custom driver.
【Enter Setup】 Acquire Scanned Data After scanning and decoding a barcode, the scanner sends the following input report: Bit Byte 7 6 5 4 3 0 Report ID = 0x02 1 Length of the barcode 2-57 Decoded data (1-56) 58-60 AIM ID 61-62 Reserved 63 - - - - - 2 1 0 - - Decoded Data Continued Send Data to the Scanner This output report is used to send data to the device. All programming commands can be used.
【Enter Setup】 Chapter 5 Symbologies Introduction Every symbology (barcode type) has its own unique attributes. This chapter provides programming barcodes for configuring the scanner so that it can identify various barcode symbologies. The more symbologies you enable, the slower your scanner decodes. It is recommended to disable those that are rarely used to improve the performance of the scanner. Note: Maximum barcode length supported by the scanner is 1024 bytes.
【Enter Setup】 Enable 1D Symbologies 【Enable 1D Symbologies】 Disable 1D Symbologies 【Disable 1D Symbologies】 Enable 2D Symbologies 【Enable 2D Symbologies】 Disable 2D Symbologies 【Disable 2D Symbologies】 **【Exit Setup】 52
【Enter Setup】 Video Reverse Regular barcode: Dark image on a bright background. Inverse barcode: Bright image on a dark background. The examples of regular barcode and inverse barcode are shown below. Regular Barcode Inverse Barcode Video Reverse is used to allow the scanner to read barcodes that are inverted. Video Reverse ON: Read both regular barcodes and inverse barcodes. Video Reverse OFF: Read regular barcodes only. The scanner shows a slight decrease in scanning speed when Video Reverse is ON.
【Enter Setup】 Code 128 Restore Factory Defaults 【Restore the Factory Defaults of Code 128】 Enable/Disable Code 128 **【Enable Code 128】 【Disable Code 128】 If the scanner fails to identify Code 128 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 128 barcode.
【Enter Setup】 Set Length Range for Code 128 The scanner can be configured to only decode Code 128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 EAN-8 Restore Factory Defaults 【Restore the Factory Defaults of EAN-8】 Enable/Disable EAN-8 **【Enable EAN-8】 【Disable EAN-8】 Transmit Check Digit EAN-8 is 8 digits in length with the last one as its check digit used to verify the integrity of the data.
【Enter Setup】 Add-On Code An EAN-8 barcode can be augmented with a two-digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is an EAN-8 barcode while the part circled by red dotted line is add-on code.
【Enter Setup】 Add-On Code Required EAN-8 Add-On Code Required: The scanner only decodes EAN-8 barcodes that contain add-on codes. EAN-8 Add-On Code Not Required: The scanner decodes a mix of EAN-8 barcodes with and without add-on codes. 【EAN-8 Add-On Code Required】 **【EAN-8 Add-On Code Not Required】 EAN-8 Extension Disable EAN-8 Zero Extend: Transmit EAN-8 barcodes as is. Enable EAN-8 Zero Extend: Add five leading zeros to decoded EAN-8 barcodes to extend to 13 digits.
【Enter Setup】 EAN-13 Restore Factory Defaults **【Restore the Factory Defaults of EAN-13】 Enable/Disable EAN-13 **【Enable EAN-13】 【Disable EAN-13】 Transmit Check Digit **【Transmit EAN-13 Check Digit】 59 【Do Not Transmit EAN-13 Check Digit】 **【Exit Setup】
【Enter Setup】 Add-On Code An EAN-13 barcode can be augmented with a two-digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is an EAN-13 barcode while the part circled by red dotted line is add-on code.
【Enter Setup】 Add-On Code Required EAN-13 Add-On Code Required: The scanner only decodes EAN-13 barcodes that contain add-on codes. EAN-13 Add-On Code Not Required: The scanner decodes a mix of EAN-13 barcodes with and without add-on codes.
【Enter Setup】 UPC-E Restore Factory Defaults **【Restore the Factory Defaults of UPC-E】 Enable/Disable UPC-E **【Enable UPC-E】 【Disable UPC-E】 If the scanner fails to identify UPC-E barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable UPC-E barcode. Transmit Check Digit UPC-E is 8 digits in length with the last one as its check digit used to verify the integrity of the data.
【Enter Setup】 Add-On Code A UPC-E barcode can be augmented with a two-digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is a UPC-E barcode while the part circled by red dotted line is add-on code.
【Enter Setup】 Add-On Code Required UPC-E Add-On Code Required: The scanner only decodes UPC-E barcodes that contain add-on codes. UPC-E Add-On Code Not Required: The scanner decodes a mix of UPC-E barcodes with and without add-on codes. 【UPC-E Add-On Code Required】 **【UPC-E Add-On Code Not Required】 Transmit System Character “0” The first character of UPC-E barcode is the system character “0”.
【Enter Setup】 UPC-E Extension Disable UPC-E Extend: Transmit UPC-E barcodes as is. Enable UPC-E Extend: Extend UPC-E barcodes to make them compatible in length to UPC-A.
【Enter Setup】 UPC-A Restore Factory Defaults Restore the Factory Defaults of UPC-A】 Enable/Disable UPC-A **【Enable UPC-A】 【Disable UPC-A】 If the scanner fails to identify UPC-A barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable UPC-A barcode. Transmit Check Digit UPC-A is 12 digits in length with the last one as its check digit used to verify the integrity of the data.
【Enter Setup】 Add-On Code A UPC-A barcode can be augmented with a two-digit or five-digit add-on code to form a new one. In the examples below, the part surrounded by blue dotted line is a UPC-A barcode while the part circled by red dotted line is add-on code.
【Enter Setup】 Add-On Code Required UPC-A Add-On Code Required: The scanner only decodes UPC-A barcodes that contain add-on codes. UPC-A Add-On Code Not Required: The scanner decodes a mix of UPC-A barcodes with and without add-on codes. 【UPC-A Add-On Code Required】 **【UPC-A Add-On Code Not Required】 Transmit Preamble Character “0” The preamble character “0” is part of the UPC-A barcode.
【Enter Setup】 Interleaved 2 of 5 Restore Factory Defaults 【Restore the Factory Defaults of Interleaved 2 of 5】 Enable/Disable Interleaved 2 of 5 **【Enable Interleaved 2 of 5】 【Disable Interleaved 2 of 5】 If the scanner fails to identify Interleaved 2 of 5 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Interleaved 2 of 5 barcode.
【Enter Setup】 Set Length Range for Interleaved 2 of 5 The scanner can be configured to only decode Interleaved 2 of 5 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 6)】 【Set the Maximum Length (Default: 100)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification A check digit is optional for Interleaved 2 of 5 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Interleaved 2 of 5 barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Interleaved 2 of 5 barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 ITF-14 ITF-14 is a special kind of Interleaved 2 of 5 with a length of 14 characters and the last character as the check character. 【Restore the Factory Defaults of ITF-14】 **【Disable ITF-14】 【Enable ITF-14 But Do Not Transmit Check Digit】 【Enable ITF-14 and Transmit Check Digit】 It is advisable not to enable ITF-14 and Interleaved 2 of 5 at the same time.
【Enter Setup】 ITF-6 ITF-6 is a special kind of Interleaved 2 of 5 with a length of 6 characters and the last character as the check character. 【Restore the Factory Defaults of ITF-6】 **【Disable ITF-6】 【Enable ITF-6 But Do Not Transmit Check Digit】 【Enable ITF-6 and Transmit Check Digit】 It is advisable not to enable ITF-6 and Interleaved 2 of 5 at the same time.
【Enter Setup】 Matrix 2 of 5 Restore Factory Defaults 【Restore the Factory Defaults of Matrix 2 of 5】 Enable/Disable Matrix 2 of 5 【Enable Matrix 2 of 5】 **【Disable Matrix 2 of 5】 If the scanner fails to identify Matrix 2 of 5 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Matrix 2 of 5 barcode.
【Enter Setup】 Set Length Range for Matrix 2 of 5 The scanner can be configured to only decode Matrix 2 of 5 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 6)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification A check digit is optional for Matrix 2 of 5 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Matrix 2 of 5 barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Matrix 2 of 5 barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 Code 39 Restore Factory Defaults 【Restore the Factory Defaults of Code 39】 Enable/Disable Code 39 **【Enable Code 39】 【Disable Code 39】 If the scanner fails to identify Code 39 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 39 barcode. Transmit Start/Stop Character Code 39 uses an asterisk (*) for both the start and the stop characters.
【Enter Setup】 Set Length Range for Code 39 The scanner can be configured to only decode Code 39 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification A check digit is optional for Code 39 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Code 39 barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Code 39 barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 Enable/Disable Code 39 Full ASCII The scanner can be configured to identify all ASCII characters by scanning the appropriate barcode below.
【Enter Setup】 Codabar Restore Factory Defaults 【Restore the Factory Defaults of Codabar】 Enable/Disable Codabar **【Enable Codabar】 【Disable Codabar】 If the scanner fails to identify Codabar barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Codabar barcode.
【Enter Setup】 Set Length Range for Codabar The scanner can be configured to only decode Codabar barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification A check digit is optional for Codabar and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Codabar barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Codabar barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 Start/Stop Character You can set the start/stop characters and choose whether or not to transmit the start/stop characters by scanning the appropriate barcode below.
【Enter Setup】 Code 93 Restore Factory Defaults 【Restore the Factory Defaults of Code 93】 Enable/Disable Code 93 **【Enable Code 93】 【Disable Code 93】 If the scanner fails to identify Code 93 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 93 barcode.
【Enter Setup】 Set Length Range for Code 93 The scanner can be configured to only decode Code 93 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 3)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification Check digits are optional for Code 93 and can be added as the last two digits, which are calculated values used to verify the integrity of the data. Disable: The scanner transmits Code 93 barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Code 93 barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 UCC/EAN-128 Restore Factory Defaults 【Restore the Factory Defaults of UCC/EAN-128】 Enable/Disable UCC/EAN-128 **【Enable UCC/EAN-128】 【Disable UCC/EAN-128】 If the scanner fails to identify UCC/EAN-128 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable UCC/EAN-128 barcode.
【Enter Setup】 Set Length Range for UCC/EAN-128 The scanner can be configured to only decode UCC/EAN-128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 GS1 Databar Restore Factory Defaults 【Restore the Factory Defaults of GS1 Databar】 Enable/Disable GS1 Databar **【Enable GS1 Databar】 【Disable GS1 Databar】 If the scanner fails to identify GS1 Databar barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable GS1 Databar barcode.
【Enter Setup】 Code 11 Restore Factory Defaults 【Restore the Factory Defaults of Code 11】 Enable/Disable Code 11 **【Enable Code 11】 【Disable Code 11】 If the scanner fails to identify Code 11 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Code 11 barcode.
【Enter Setup】 Set Length Range for Code 11 The scanner can be configured to only decode Code 11 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 2)】 【Set the Maximum Length (Default: 127】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification Check digits are optional for Code 11 and can be added as the last one or two digits, which are calculated values used to verify the integrity of the data. If the Disable option is enabled, the scanner transmits Code 11 barcodes as is.
【Enter Setup】 ISBN Restore Factory Defaults 【Restore the Factory Defaults of ISBN】 Enable/Disable ISBN 【Enable ISBN】 **【Disable ISBN】 If the scanner fails to identify ISBN barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable ISBN barcode.
【Enter Setup】 Add-On Code An ISBN barcode can be augmented with a two-digit or five-digit add-on code to form a new one. 【Enable 2-Digit Add-On Code】 **【Disable 2-Digit Add-On Code】 【Enable 5-Digit Add-On Code】 **【Disable 5-Digit Add-On Code】 Enable 2-Digit Add-On Code/ Enable 5-Digit Add-On Code: The scanner decodes a mix of ISBN barcodes with and without 2-digit/5-digit add-on codes.
【Enter Setup】 Add-On Code Required ISBN Add-On Code Required: The scanner only decodes ISBN barcodes that contain add-on codes. ISBN Add-On Code Not Required: The scanner decodes a mix of ISBN barcodes with and without add-on codes.
【Enter Setup】 ISSN Restore Factory Defaults 【Restore the Factory Defaults of ISSN】 Enable/Disable ISSN 【Enable ISSN】 **【Disable ISSN】 If the scanner fails to identify ISSN barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable ISSN barcode.
【Enter Setup】 Add-On Code An ISSN barcode can be augmented with a two-digit or five-digit add-on code to form a new one. 【Enable 2-Digit Add-On Code】 **【Disable 2-Digit Add-On Code】 【Enable 5-Digit Add-On Code】 **【Disable 5-Digit Add-On Code】 Enable 2-Digit Add-On Code/ Enable 5-Digit Add-On Code: The scanner decodes a mix of ISSN barcodes with and without 2-digit/5-digit add-on codes.
【Enter Setup】 Add-On Code Required ISSN Add-On Code Required: The scanner only decodes ISSN barcodes that contain add-on codes. ISSN Add-On Code Not Required: The scanner decodes a mix of ISSN barcodes with and without add-on codes.
【Enter Setup】 AIM-128 Restore Factory Defaults 【Restore the Factory Defaults of AIM-128】 Enable/Disable AIM-128 **【Enable AIM-128】 【Disable AIM-128】 If the scanner fails to identify AIM-128 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable AIM-128 barcode.
【Enter Setup】 Set Length Range for AIM-128 The scanner can be configured to only decode AIM-128 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Industrial 25 Restore Factory Defaults 【Restore the Factory Defaults of Industrial 25】 Enable/Disable Industrial 25 **【Enable Industrial 25】 【Disable Industrial 25】 If the scanner fails to identify Industrial 25 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Industrial 25 barcode.
【Enter Setup】 Set Length Range for Industrial 25 The scanner can be configured to only decode Industrial 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 6)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification A check digit is optional for Industrial 25 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Industrial 25 barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Industrial 25 barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 Standard 25 Restore Factory Defaults 【Restore the Factory Defaults of Standard 25】 Enable/Disable Standard 25 **【Enable Standard 25】 【Disable Standard 25】 If the scanner fails to identify Standard 25 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Standard 25 barcode.
【Enter Setup】 Set Length Range for Standard 25 The scanner can be configured to only decode Standard 25 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 6)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification A check digit is optional for Standard 25 and can be added as the last digit. It is a calculated value used to verify the integrity of the data. Disable: The scanner transmits Standard 25 barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Standard 25 barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 Plessey Restore Factory Defaults 【Restore the Factory Defaults of Plessey】 Enable/Disable Plessey 【Enable Plessey】 **【Disable Plessey】 If the scanner fails to identify Plessey barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Plessey barcode.
【Enter Setup】 Set Length Range for Plessey The scanner can be configured to only decode Plessey barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification Check digits are optional for Plessey and can be added as the last two digits, which are calculated values used to verify the integrity of the data. Disable: The scanner transmits Plessey barcodes as is. Do Not Transmit Check Digit After Verification: The scanner checks the integrity of all Plessey barcodes to verify that the data complies with the check digit algorithm.
【Enter Setup】 MSI-Plessey Restore Factory Defaults 【Restore the Factory Defaults of MSI-Plessey】 Enable/Disable MSI-Plessey 【Enable MSI-Plessey】 **【Disable MSI-Plessey】 If the scanner fails to identify MSI-Plessey barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable MSI-Plessey barcode.
【Enter Setup】 Set Length Range for MSI-Plessey The scanner can be configured to only decode MSI-Plessey barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 2)】 【Set the Maximum Length (Default: 127)】 Maximum length of a 1D barcode should not exceed 127 bytes.
【Enter Setup】 Check Digit Verification Check digits are optional for MSI-Plessey and can be added as the last one or two digits, which are calculated values used to verify the integrity of the data. If the Disable option is enabled, the scanner transmits MSI-Plessey barcodes as is.
【Enter Setup】 PDF417 Restore Factory Defaults **【Restore the Factory Defaults of PDF417】 Enable/Disable PDF417 **【Enable PDF417】 【Disable PDF417】 If the scanner fails to identify PDF417 barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable PDF417 barcode.
【Enter Setup】 Set Length Range for PDF417 The scanner can be configured to only decode PDF417 barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 1024)】 Maximum length of a 2D barcode should not exceed 1024 bytes. Minimum length is not allowed to be greater than maximum length.
【Enter Setup】 QR Code Restore Factory Defaults 【Restore the Factory Defaults of QR Code】 Enable/Disable QR Code **【Enable QR Code】 【Disable QR Code】 If the scanner fails to identify QR Code barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable QR Code barcode.
【Enter Setup】 Set Length Range for QR Code The scanner can be configured to only decode QR Code barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 1024)】 Maximum length of a 2D barcode should not exceed 1024 bytes. Minimum length is not allowed to be greater than maximum length.
【Enter Setup】 Micro QR **【Enable Micro QR】 **【Exit Setup】 【Disable Micro QR】 118
【Enter Setup】 Data Matrix Restore Factory Defaults 【Restore the Factory Defaults of Data Matrix】 Enable/Disable Data Matrix **【Enable Data Matrix】 【Disable Data Matrix】 If the scanner fails to identify Data Matrix barcodes, you may first try this solution by scanning the Enter Setup barcode and then Enable Data Matrix barcode.
【Enter Setup】 Set Length Range for Data Matrix The scanner can be configured to only decode Data Matrix barcodes with lengths that fall between (inclusive) the minimum and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths. 【Set the Minimum Length (Default: 1)】 【Set the Maximum Length (Default: 1024)】 Maximum length of a 2D barcode should not exceed 1024 bytes. Minimum length is not allowed to be greater than maximum length.
【Enter Setup】 Rectangular Barcode Data Matrix has two formats: Square barcodes having the same amount of modules in length and width: 10*10, 12*12.... 144*144. Rectangular barcodes having different amounts of models in length and width: 6*16, 6*14... 14*22.
【Enter Setup】 Chapter 6 Prefix & Suffix Introduction A 1D barcode could contain digits, letters, symbols, etc. A 2D barcode could contain more data, such as Chinese characters and other multi-byte characters. However, in real applications, they do not and should not have all information we need, such as barcode type, data acquisition time and delimiter, in order to keep the barcodes short and flexible. Preffix and suffix are how to fulfill the needs mentioned above.
【Enter Setup】 General Settings Enable/Disable All Prefix/Suffix Disable All Prefix/Suffix: Transmit barcode data with no prefix/suffix. Enable All Prefix/Suffix: Allow user to append Code ID prefix, AIM ID prefix, custom prefix/suffix and terminating character to the barcode data before the transmission.
【Enter Setup】 Custom Prefix Enable/Disable Custom Prefix If custom prefix is enabled, you are allowed to append to the data a user-defined prefix that cannot exceed 10 characters. For example, if the custom prefix is “AB” and the barcode data is “123”, the Host will receive “AB123”. **【Disable Custom Prefix】 【Enable Custom Prefix】 Set Custom Prefix To set a custom prefix, scan the Set Custom Prefix barcode and then the numeric barcodes corresponding to the hexadecimal value of a desired prefix.
【Enter Setup】 AIM ID Prefix AIM (Automatic Identification Manufacturers) ID defines symbology identifier (For the details, see the AIM ID Table in Appendix). If AIM ID prefix is enabled, the scanner will add the symbology identifier before the scanned data after decoding. **【Disable AIM ID Prefix】 【Enable AIM ID Prefix】 AIM ID is not user programmable. Code ID Prefix Code ID can also be used to identify barcode type. Unlike AIM ID, Code ID is user programmable.
【Enter Setup】 Restore All Default Code IDs For the information of default Code IDs, see the Code ID Table in Appendix. 【Restore All Default Code IDs】 Modify Code ID See the examples below to learn how to modify a Code ID and restore the default Code IDs of all symbologies. Modify PDF417 Code ID to be “p” (its hexadecimal value is 0x70): 1. Scan the Enter Setup barcode. 2. Scan the Modify PDF417 Code ID barcode. 3. Scan the numeric barcodes “7” and “0”. (See the Digit Barcodes in Appendix) 4.
【Enter Setup】 【Modify PDF417 Code ID】 【Modify Data Matrix Code ID】 【Modify QR Code ID】 【Modify ISSN Code ID】 【Modify EAN-8 Code ID】 127 【Modify Matrix 25 Code ID】 【Modify AIM-128 Code ID】 【Modify ITF-6 Code ID】 **【Exit Setup】
【Enter Setup】 【Modify EAN-13 Code ID】 【Modify UPC-E Code ID】 【Modify UPC-A Code ID】 【Modify Interleaved 2 of 5 Code ID】 **【Exit Setup】 【Modify Code 39 Code ID】 【Modify Codabar Code ID】 【Modify Code 93 Code ID】 【Modify Code 128 Code ID】 128
【Enter Setup】 【Modify ITF-14 Code ID】 【Modify UCC/EAN-128 Code ID】 【Modify Code 11 Code ID】 【Modify Plessey Code ID】 【Modify ISBN Code ID】 【Modify Industrial 25 Code ID】 【Modify Standard 25 Code ID】 【Modify MSI-Plessey Code ID】 【Modify GS1 Databar Code ID】 129 **【Exit Setup】
【Enter Setup】 Custom Suffix Enable/Disable Custom Suffix If custom suffix is enabled, you are allowed to append to the data a user-defined suffix that cannot exceed 10 characters. For example, if the custom suffix is “AB” and the barcode data is “123”, the Host will receive “123AB”. **【Disable Custom Suffix】 【Enable Custom Suffix】 Set Custom Suffix To set a custom suffix, scan the Set Custom Suffix barcode and then the numeric barcodes corresponding to the hexadecimal value of a desired suffix.
【Enter Setup】 Terminating Character Suffix Enable/Disable Terminating Character Suffix A terminating character such as carriage return (CR) or carriage return/line feed pair (CRLF) can only be used to mark the end of data, which means nothing can be added after it.
【Enter Setup】 To set a terminating character suffix, scan the Set Terminating Character Suffix barcode and the numeric barcodes representing the hexadecimal value of a desired terminating character and then scan the Save barcode. Refer to the ASCII Table in Appendix for hexadecimal values of terminating characters. Note: A terminating character suffix cannot exceed 2 characters. 【Set Terminating Character Suffix】 Set the terminating character suffix to 0x0A: **【Exit Setup】 1.
【Enter Setup】 Chapter 7 Ambient Illumination Ambient lighting conditions may vary from one operating environment to another, such as fluorescent lit warehouses or sunlit open spaces. Fluorescent lights may flicker when using AC power source in 50-60Hz. Usually indoor illuminance is around 1,000 lux while outdoor illuminance may reach 60,000 lux or even over 100,000 lux. Two options are provided for ambient illumination settings: Normal Illuminance: applicable to most indoor/outdoor environments.
Appendix Digit Barcodes After scanning numeric barcode(s), you need to scan the Save barcode to save the data.
6~9 【6】 【7】 【8】 【9】 135
A~F 【A】 【B】 【C】 【D】 【E】 【F】 136
Save/Cancel Barcodes After reading numeric barcode(s), you need to scan the Save barcode to save the data. If you scan the wrong digit(s), you can either scan the Cancel barcode and then start the configuration all over again, or scan the Delete the Last Digit barcode and then the correct digit, or scan the Delete All Digits barcode and then the digits you want.
Factory Defaults Table Parameter Factory Default System Settings Barcode Programming Disabled Auto Power-Off Timeout 5 minutes Illumination Aiming Startup Beep Normal Normal Enabled Enabled Type 3 Loud Do not transmit Null Manual mode Notification Good Read Beep Beep Type Beep Volume NGR (Not Good Read) Message Scan Mode Remark Applicable to Manual mode only Applicable to Trigger mode, Decode Session Timeout 3,000ms Manual Mode Sense mode and Continuous mode 1~3,600,000ms; 0: Infinite.
Parameter Factory Default Remark Communication Settings Wireless Communication Mode Synchronous Mode USB HID-KBW USB HID-KBW RS-232 USB HID-KBW Baud Rate 115200 Parity Check None Number of Data Bits 8 Number of Stop Bits 1 Hardware Flow Control Disabled Examine KBW Connection Enabled USB Country Keyboard Type U.S.
Parameter Factory Default Remark Symbologies Video Reverse Disabled Applicable to all symbologies.
Parameter Factory Default ISBN ISBN Disabled ISBN Format ISBN-13 2-Digit Add-On Code Disabled 5-Digit Add-On Code Disabled Add-On Code Not required UPC-E UPC-E Enabled Check Digit Transmit 2-Digit Add-On Code Disabled 5-Digit Add-On Code Disabled Add-On Code Not required Extend to UPC-A Disabled System Character “0” Do not transmit UPC-A UPC-A Enabled Check Digit Transmit 2-Digit Add-On Code Disabled 5-Digit Add-On Code Disabled Add-On Code Not required Preamble Character
Parameter Factory Default Remark ITF-14 ITF-14 Disabled Check Digit Matrix 2 of 5 Do not transmit 出 Matrix 2 of 5 Disabled Check Digit Verification Enabled Check Digit Do not transmit Maximum Length 127 Minimum Length 6 Industrial 2 of 5 Industrial 2 of 5 Enabled Check Digit Verification Disabled Check Digit Do not transmit Maximum Length 127 Minimum Length 6 Standard 2 of 5 Standard 2 of 5 Enabled Check Digit Verification Disabled Check Digit Do not transmit Maximum Length
Parameter Factory Default Codabar Codabar Enabled Check Digit Verification Disabled Check Digit Do not transmit Start/Stop Character Do not transmit Start/Stop Character Format ABCD/ABCD Maximum Length 127 Minimum Length 1 Code 93 Code 93 Enabled Check Digit Verification Enabled Check Digit Do not transmit Maximum Length 127 Minimum Length 3 GS1 Databar GS1 Databar Enabled Application Identifier “01” Transmit Code 11 Code 11 Enabled Check Digit Verification One check digit,
Parameter Factory Default Remark MSI-Plessey MSI-Plessey Disabled Check Digit Verification One check digit, MOD10 Check Digit Do not transmit Maximum Length 127 Minimum Length 2 PDF 417 PDF 417 Enabled Maximum Length 1024 Minimum Length 1 QR Code QR Code Enabled Micro QR Enabled Maximum Length 1024 Minimum Length 1 Data Matrix Data Matrix Enabled Rectangular Barcode Enabled Mirror Image Decode Maximum Length 1024 Minimum Length 1 144
AIM ID Table Symbology EAN-13 EAN-8 AIM ID ]E0 Standard EAN-13 ]E3 EAN-13 + 2/5-Digit Add-On Code ]E4 Standard EAN-8 ]E4…]E1… EAN-8 + 2-Digit Add-On Code ]E4…]E2… EAN-8 + 5-Digit Add-On Code ]E0 Standard UPC-E ]E3 UPC-E + 2/5-Digit Add-On Code ]E0 Standard UPC-A ]E3 UPC-A + 2/5-Digit Add-On Code Code 128 ]C0 Standard Code 128 UCC/EAN-128 ]C1 FNC1 is the character right after the start character AIM-128 ]C2 FNC1 is the 2nd character after the start character ISBT-128 ]C4 UPC-E
Symbology AIM ID Remark ]F0 Standard Codabar ]F2 Transmit check digit after verification ]F4 Do not transmit check digit after verification ]G0 Standard Code 93 ]H0 One check digit MOD11; transmit check digit ]H1 Two check digits, MOD11/MOD11; transmit check digit ]H3 Do not transmit check digit after verification ]H9 No check digit verification GS1-DataBar (RSS) ]e0 Standard GS1-DataBar Plessey ]P0 Standard Plessey ]M0 One check digit, MOD10; transmit check digit ]M1 One check d
Symbology AIM ID Remark ]Q0 QR1 ]Q1 2005 version, ECI excluded ]Q2 2005 version, ECI included ]Q3 QR Code ]Q4 ]Q5 ]Q6 QR Code 2005, ECI excluded, FNC1 is the 1st character after the start character QR Code 2005, ECI included, FNC1 is the 1st character after the start character QR Code 2005,ECI excluded,FNC1 is the 2nd character after the start character QR Code 2005, ECI included, FNC1 is the 2nd character after the start character Reference: ISO/IEC 15424:2008 Information technology – Automatic
Code ID Table Symbology Code ID Code 128 j UCC/EAN-128 j AIM-128 f EAN-8 d EAN-13 d ISSN n ISBN B UPC-E c UPC-A c Interleaved 2 of 5 e ITF-6 e ITF-14 e Matrix 2 of 5 v Industrial 2 of 5 D Standard 2 of 5 s Code 39 b Codabar a Code 93 i Code 11 H Plessey p MSI-Plessey m GS1 Databar R PDF417 r QR Code Q Data Matrix u 148
ASCII Table 149 Hex Dec Char 00 0 NUL (Null char.
Hex Dec Char 1e 30 RS (Request to Send) 1f 31 US (Unit Separator) 20 32 SP (Space) 21 33 ! (Exclamation Mark) 22 34 " (Double Quote) 23 35 # (Number Sign) 24 36 $ (Dollar Sign) 25 37 % (Percent) 26 38 & (Ampersand) 27 39 ` (Single Quote) 28 40 ( (Left / Opening Parenthesis) 29 41 ) (Right / Closing Parenthesis) 2a 42 * (Asterisk) 2b 43 + (Plus) 2c 44 , (Comma) 2d 45 - (Minus / Dash) 2e 46 .
151 Hex Dec Char 3e 62 > (Greater Than) 3f 63 ? (Question Mark) 40 64 @ (AT Symbol) 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 [ (Left / Opening Bracket) 5c 92 \ (Back Slash) 5d 93 ] (Right / Closing Bracket)
Hex 5e 5f 60 61 62 63 64 65 66 67 68 69 6a 6b 6c 6d 6e 6f 70 71 72 73 74 75 76 77 78 79 7a 7b 7c 7d 7e 7f Dec 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 Char ^ _ ' a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL (Caret / Circumflex) (Underscore) (Grave Accent) (Left/ Opening Brace) (Vertical Bar) (Right/Closing Brace) (Tilde) (Delete) 152
ASCII Function Key Mapping Table ASCII Function ASCII Value (HEX) No Function Key Mapping Function Key Mapping NUL (Null char.
ASCII Function Key Mapping Table (Continued) The function key mappings of the last five characters in the previous table differ from one keyboard layout to another. Function Key Mapping Country/ Keyboard Layout 1B 1C 1D 1E 1F United States Ctrl+[ Ctrl+\ Ctrl+] Ctrl+6 Ctrl+- Belgium Ctrl+[ Ctrl+< Ctrl+] Ctrl+6 Ctrl+- Scandinavia Ctrl+8 Ctrl+< Ctrl+9 Ctrl+6 Ctrl+- France Ctrl+^ Ctrl+8 Ctrl+$ Ctrl+6 Ctrl+= Germany Ctrl+Ã Ctrl++ Ctrl+6 Ctrl+- Italy Ctrl+\ Ctrl++ Ctrl+6 Ct
Warning Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Headquarters Fujian Newland Auto-ID Tech. Co., Ltd. 3F, Building A, No.1, Rujiang West Rd., Mawei, Fuzhou, Fujian, China 350015 TEL: +86 - (0) 591-83978605 FAX: +86 - (0) 591-83979216 E-mail: marketing@nlscan.com WEB:www.nlscan.com Newland Europe BV Rolweg 25, 4104 AV Culemborg, The Netherlands TEL: +31 (0) 345 87 00 33 FAX: +31 (0) 345 87 00 39 Email: info@newland-id.com WEB: www.newland-id.com Tech Support: tech-support@newland-id.com Newland North America Inc. Address: 46559 Fremont Blvd.