Home Theater Screen User Manual

3 - 3
Connecting the UG00P-U2
2
The UG00P-U2 (serial connection I/O unit) is connected with the UG520/420/320/221/220. It uses 16 input
points and 16 output points for connection to an external device such as a PLC. Note that the UG00P-U2
cannot be used with the UG00P-U1 simultaneously.
External Dimensions
Warning
Turn OFF the power before mounting, dismounting, wiring, maintaining, or checking, otherwise, electric
shock, erratic operation, or troubles might occur.
Caution
The serial connection I/O unit uses a link. Therefore, do not use the unit in places where high-speed
operations, urgent operations, or dangerous operations (emergency stop-type) are performed.
83
158
MJ1
FG INO IN2 IN4 IN6 IN8 IN10 IN12 IN14 COM OUT0 OUT2 OUT4 OUT6 COM1 OUT9 OUT11 OUT13 OUT15
24V DC
IN1
IN3
IN5
IN7
IN9 IN11 IN13 IN15 OUT1 OUT3 OUT5 OUT7 OUT8 OUT10 OUT12 OUT14 COM2
188
90
B1
B2
B3
B4 B5
B6
B7 B8
B9
B10 B11
B12
B15 B16
B17
B18 B19
B20
A1 A2
A3
A4
B13
B14
A5 A6
A7
A8 A9
A10
A11 A12
A13
A14 A15
A16
A17
A18 A19
A20
30
36
78
180
2 Connecting the UG00P-U2