Step 3
Connect each RF cable to its corresponding port on the RU.
Step 4
Please the weatherproofing on each connector according to local guidelines.
Note: Fujitsu recommends using self-fusing tape for weat herproofing cables.
Step 5
Secure the RF cables along their rout e.
Step 6
Torque each connection to 5 N/ m
Cont inue with the next task.
5.7.5
Check Connections and DC Power Polarity
This procedure describes how to perform checks before turning on the power.
Step 1
Verify that all necessary cables are connected to the RU connectors.
Step 2
Check the polarit y of DC power supply.
Note: The Radio Unit does not have a power swit ch. DC power is cont rolled by a circuit breaker at the DC
power source. Do not turn on the circuit breaker before start ing up of the RU.
Note: It takes approximately 10 seconds for the RU to fully power up.
Cont inue with the next task.
Installation
Cable Installation
102
Release 1.0 ยท Issue 1, M arch 2021
Fujitsu and Fujitsu Customer Use Only