5 Attach a new brake roller on the shaft.
Insert the protrusion on the shaft into the slot.
6 Attach the shaft.
1 Insert the left end of the shaft into the hole in accordance with the
hole shape, and then attach the right side of the shaft.
2 Close the cover.
7 Close the ADF.
For details, refer to "1.4 Opening/Closing the ADF" (page 27).
8 Reset the brake roller counter.
Reset the counter by performing one of the following actions:
z Reset the counter in [4: Consumable counters] on the [Settings
Menu] screen of the operator panel.
For details, refer to "4.2 Settings Menu" (page 66).
z Reset the counter in the Software Operation Panel.
For details, refer to "Resetting the sheet counters" (page 179).
Slot
Protrusion
Shaft
Brake roller
2
1
Shaft
Brake roller
ATTENTION
Confirm that the brake roller is installed properly. Otherwise, it may
cause feeding errors such as paper jams.
Be careful not to have your fingers caught