6 Attach the two new pick rollers on the shaft on at a time.
1 Insert the retaining clip of the pick roller into the slot.
2 Insert the retaining clip of the other pick roller into the slot.
7 Attach the shaft.
1 Insert the left end of the shaft into the slot, and lower the other end
gradually.
2 Rotate the bushing to lock the shaft.
ATTENTION
Confirm that the pick roller is installed properly. Otherwise, it may
cause feeding errors such as paper jams.
Make sure to insert the pick roller until it locks in place.
Slot
Shaft
Retaining clip
Pick roller
Slot
Shaft
Retaining clip
Pick roller
Shaft
Bushing
Shaft