Important notes Power cord selection
6
A26391-K84-Z100-1-7619
Power cord selection
The power cord for this unit has been packed separately and has been selected according to the
country of destination. It must be used to prevent electric shock. Use the following guidelines if it is
necessary to replace the original cord set.
The female receptacle of the cord set must meet
IEC 320 requirements.
For the United States and Canada
Use a UL listed and CSA labeled cord set consisting of a two conductor cord with a maximum length of
15 feet.
For units which stand on a desk or table, type SVT or SJT cord sets shall be used.
For units which stand on floor, only SJT type cord sets shall be used.
The cord set must be selected according to the current rating for your unit. Please consult Table A for
the selection criteria for power cords used in the United States and Canada.
Table A:
Cord Type Size of Conductors
in Cord
Maximum Current
Rating of Unit
SJT 18 AWG
16 AWG
14 AWG
10 Amps
12 Amps
12 Amps
SVT 18 AWG
17 AWG
10 Amps
12 Amps
For units set at 115 V:
use a parallel blade attachment plug rated 15 A,
125 V.
For units set at 230 V (outside of the United States and Canada):
use a cord set consisting of a minimum AWG according to Table A and an attachment plug rated 15 A,
250 V. The cord set should have the appropriate safety approvals for the country in which the
equipment will be installed and should be marked HAR.