Operating Manual

Table Of Contents
A26361-K520-Z100-1-7619
45
Technical data
Electrical data
Regulations complied with: EN 60950 / VDE 0805
UL 1950
CSA 22.2 No.950
Protection class: I
Rated voltage range: (selectable) 100 V to 125 V / 200 V to 240 V
Frequency: 50 Hz - 60 Hz
Max. rated current
System unit with monitor socket:
Monitor socket (output)
100 V - 125 V / 5,5 A
200 V - 240 V / 3,0 A
100 V - 125 V / 3 A
200 V - 240 V / 1.5 A
Typical power draw in operation:
Power draw in energy saving mode:
Power draw in the 'ready' status
< 35 W *)
< 28 W *)
< 3 W *)
Dimensions
Width/Depth/Height:
Weight:
454 mm/473 mm/139 mm
ca. 11 kg (107,9 N) in basic configuration
Environmental conditions
Environment class (3K2)
Environment class (2K2)
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature:
Operating (3K2)
Transport (2K2)
15 °C .... 35 °C
-25 °C .... 60 °C
Condensation in operating must be avoided.
Clearance required to ensure adequate ventilation:
left-hand side
front
rear
min. 200 mm
min. 200 mm
min. 200 mm
!
Do not place several system units one above the other.
*) These values only apply for a SCENIC 600 with the configuration below. When additional
components are incorporated, the power consumption in energy saving mode may exceed the
requirements for the environment symbol ("Blue Angel") (30 W).
Processor (512 Kbyte cache):
Main memory:
Floppy disk drive:
Hard disk drive:
CD-ROM drive:
Graphics:
LAN:
Pentium II MMX at 450 MHz
192 Mbytes
1.44 Mbytes
6,4 Gbyte
32fold
Matrox MGA G100 AGP
10/100 MBit Ethernet Controller onboard