Design and Technical Manual

Table Of Contents
4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ASUG09LMAS
AFR CFM 453
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW
5 3 8.87 1.18 8.64 1.20 8.50 1.23 8.18 1.25 7.95 1.28
14 12 9.87 1.25 9.61 1.28 9.35 1.31 9.10 1.33 8.84 1.36
23 19 11.61 1.33 11.31 1.35 11.00 1.38 10.70 1.41 10.40 1.44
32 28 13.19 1.43 12.84 1.46 12.50 1.49 12.15 1.52 11.81 1.54
41 37 14.60 1.52 14.22 1.55 13.83 1.58 13.45 1.61 13.07 1.64
47 43 15.84 1.54 15.43 1.57 15.00 1.61 14.60 1.63 14.18 1.66
50 47 15.92 1.56 15.51 1.59 15.09 1.62 14.67 1.65 14.26 1.68
59 50 16.09 1.47 15.67 1.49 15.25 1.53 14.83 1.56 14.41 1.58
68 59 15.18 1.14 14.78 1.17 14.38 1.19 13.99 1.21 13.59 1.24
75 64 15.68 1.20 15.27 1.22 14.86 1.25 14.45 1.27 14.03 1.30
AFR
m
3
/h
770
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15.0 -16.1 2.60 1.18 2.53 1.20 2.49 1.23 2.40 1.25 2.33 1.28
-10.0 -11.1 2.89 1.25 2.82 1.28 2.74 1.31 2.67 1.33 2.59 1.36
-5.0 -7.2 3.40 1.33 3.31 1.35 3.23 1.38 3.14 1.41 3.05 1.44
0.0 -2.2 3.87 1.43 3.76 1.46 3.66 1.49 3.56 1.52 3.46 1.54
5.0 2.8 4.28 1.52 4.17 1.55 4.05 1.58 3.94 1.61 3.83 1.64
8.3 6.1 4.64 1.54 4.52 1.57 4.40 1.61 4.28 1.63 4.16 1.66
10.0 8.3 4.67 1.56 4.55 1.59 4.42 1.62 4.30 1.65 4.18 1.68
15.0 10.0 4.72 1.47 4.59 1.49 4.47 1.53 4.35 1.56 4.22 1.58
20.0 15.0 4.45 1.14 4.33 1.17 4.22 1.19 4.10 1.21 3.98 1.24
24.0 18.0 4.59 1.20 4.47 1.22 4.35 1.25 4.23 1.27 4.11 1.30
¢
Model: ASUG12LMAS
AFR CFM 453
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW
5 3 11.29 1.23 11.00 1.25 10.70 1.28 10.40 1.30 10.11 1.33
14 12 12.56 1.31 12.23 1.33 11.90 1.36 11.57 1.39 11.24 1.41
23 19 14.77 1.38 14.39 1.41 14.00 1.44 13.61 1.47 13.23 1.50
32 28 16.78 1.49 16.34 1.52 15.90 1.55 15.46 1.58 15.02 1.61
41 37 18.57 1.58 18.09 1.62 17.60 1.65 17.11 1.68 16.63 1.71
47 43 20.16 1.60 19.63 1.63 19.10 1.67 18.57 1.70 18.04 1.73
50 47 20.26 1.62 19.73 1.65 19.20 1.69 18.67 1.72 18.14 1.75
59 50 20.47 1.53 19.94 1.56 19.40 1.59 18.86 1.62 18.33 1.65
68 59 19.31 1.19 18.81 1.21 18.30 1.24 17.79 1.26 17.29 1.29
75 64 19.94 1.25 19.42 1.27 18.90 1.30 18.38 1.32 17.86 1.35
AFR
m
3
/h
770
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15.0 -16.1 3.31 1.23 3.22 1.25 3.14 1.28 3.05 1.30 2.96 1.33
-10.0 -11.1 3.68 1.31 3.58 1.33 3.49 1.36 3.39 1.39 3.30 1.41
-5.0 -7.2 4.33 1.38 4.22 1.41 4.10 1.44 3.99 1.47 3.88 1.50
0.0 -2.2 4.92 1.49 4.79 1.52 4.66 1.55 4.53 1.58 4.40 1.61
5.0 2.8 5.44 1.58 5.30 1.62 5.16 1.65 5.02 1.68 4.87 1.71
8.3 6.1 5.91 1.60 5.75 1.63 5.60 1.67 5.44 1.70 5.29 1.73
10.0 8.3 5.94 1.62 5.78 1.65 5.63 1.69 5.47 1.72 5.32 1.75
15.0 10.0 6.00 1.53 5.84 1.56 5.69 1.59 5.53 1.62 5.37 1.65
20.0 15.0 5.66 1.19 5.51 1.21 5.36 1.24 5.22 1.26 5.07 1.29
24.0 18.0 5.85 1.25 5.69 1.27 5.54 1.30 5.39 1.32 5.23 1.35
- 9 -
4-2. Heating capacity 4. Capacity table
WALL MOUNTED
ASUG09-12LMAS
WALL MOUNTED
ASUG09-12LMAS