Design and Technical Manual

Table Of Contents
¢
External heater output
Control Primary heater Auxiliary heater
Function setting
Indoor unit Wired R. C.
Control switching
external heaters
No. 61
Sensor activation*
2
Auxiliary heater
control 1
Heat pump
External device*
1
61-00
Auxiliary heater
control 2
Heat pump External device 61-01
Heat pump prohibition
control
External device None 61-02 On (Enabled)
Auxiliary heater
control by outdoor
temperature 1
Heat pump External device 61-03 On (Enabled)
Auxiliary heater
control by outdoor
temperature 2
Heat Pump External device 61-04 On (Enabled)
NOTES:
After turning off the heater, 3 minutes of standby time is required by next power-on of the
heater.
For items marked “—” in the table, any of validate or invalidate of the setting are acceptable.
*1: External device means Hot water, Electrical heater, etc.
*2: Sensor activation:
Setting change from the factory setting is required.
Indoor unit fan setting will be on for safety reason without sensor activation of wired remote
controller.
Installation configuration of individual connection
External heating device is installed individually. (No use of indoor unit fan)
ON / OFF
Example of heating device:
- Floor heating device
WARNING
Design and install external heater appropriately with considering its protection.
Inappropriate designing and installation of external heater may cause a fire by emitted heat from
the external heater.
Fujitsu General Ltd. is not responsible for inappropriate designing or installation of external
heating device.
- 25 -
8-4. Details of function 8. External input and output
WALL MOUNTED
ASUG09-12LMAS
WALL MOUNTED
ASUG09-12LMAS