Service Manual
Table Of Contents
- SERVICE MANUAL
- 1. GENERAL INFORMATION
- 2. TECHNICAL DATA AND PARTS LIST
- 3. TROUBLESHOOTING
- 1. Error code
- 2. Troubleshooting with error code
- 2-1. E: 11. Serial communication error (Serial reverse transfer error) (Outdoor unit)
- 2-2. E: 11. Serial communication error (Serial forward transfer error) (Indoor unit)
- 2-3. E: 12. Wired remote controller communication error (Indoor unit)
- 2-4. E: 18. External communication error (Indoor unit)
- 2-5. E: 32. Indoor unit main PCB error (Indoor unit)
- 2-6. E: 35. MANUAL AUTO button error (Indoor unit)
- 2-7. E: 41. Room temperature sensor error (Indoor unit)
- 2-8. E: 42. Indoor unit heat exchanger sensor error (Indoor unit)
- 2-9. E: 51. Indoor unit fan motor error (Indoor unit)
- 2-10. E: 58. Intake grille error (Indoor unit)
- 2-11. E: 62. Outdoor unit main PCB error (Outdoor unit)
- 2-12. E: 63. Inverter error (Outdoor unit)
- 2-13. E: 64. PFC circuit error (Outdoor unit)
- 2-14. E: 71. Discharge thermistor error (Outdoor unit)
- 2-15. E: 73. Outdoor unit heat exchanger thermistor error (Outdoor unit)
- 2-16. E: 74. Outdoor temperature thermistor error (Outdoor unit)
- 2-17. E: 84. Current sensor error (Outdoor unit)
- 2-18. E: 94. Trip detection (Outdoor unit)
- 2-19. E: 95. Compressor motor control error (Outdoor unit)
- 2-20. E: 97. Outdoor unit fan motor error (Outdoor unit)
- 2-21. E: 99. 4-way valve error (Outdoor unit)
- 2-22. E: A1. Discharge temperature error (Outdoor unit)
- 3. Troubleshooting without error code
- 4. Troubleshooting with error code (For wireless LAN adapter)
- 4-1. E: 18. External communication error between indoor unit and WLAN adapter
- 4-2. Wireless LAN adapter error
- 4-3. Network communication error between wireless LAN router and WLAN adapter
- 4-4. E: 18. Communication error
- 4-5. E: 18. Wireless LAN adapter non-energized
- 4-6. Wireless LAN adapter Sleep mode (Indoor unit)
- 4-7. Mobile app setting method
- 5. Service parts information
- 6. Thermistor resistance values
- 4. CONTROL AND FUNCTIONS
- 1. Compressor frequency control
- 2. Auto changeover operation
- 3. Fan control
- 4. Louver control
- 5. Timer operation control
- 6. Defrost operation control
- 7. Various control
- 7-1. Auto restart
- 7-2. MANUAL AUTO operation
- 7-3. Forced cooling operation
- 7-4. 10 °C HEAT operation
- 7-5. ECONOMY operation
- 7-6. POWERFUL operation
- 7-7. Compressor preheating
- 7-8. Electronic expansion valve control
- 7-9. Prevention to restart for 3 minutes (3 minutes st)
- 7-10. 4-way valve control
- 7-11. Outdoor unit low noise operation
- 8. Various protections
- 5. FILED WORKING
CONTENTS
4. CONTROL AND FUNCTIONS
1. Compressor frequency control..................................................................04-1
1-1. Cooling operation ...........................................................................................................04-1
1-2. Heating operation ...........................................................................................................04-3
1-3. Dry operation..................................................................................................................04-4
1-4. Compressor frequency at normal start-up ......................................................................04-4
1-5. Compressor frequency limitation by outdoor temperature ..............................................04-5
2. Auto changeover operation........................................................................04-7
3. Fan control...................................................................................................04-9
3-1. Indoor fan control............................................................................................................04-9
3-2. Outdoor fan control.......................................................................................................04-13
4. Louver control ...........................................................................................04-16
4-1. Vertical airflow direction louver control .........................................................................04-16
4-2. Horizontal airflow direction louver control .....................................................................04-16
4-3. Swing operation............................................................................................................04-17
5. Timer operation control ............................................................................04-18
5-1. Wireless remote control................................................................................................04-18
5-2. Wired remote control ....................................................................................................04-20
6. Defrost operation control .........................................................................04-23
6-1. Defrost operation in heating operation stopped ............................................................04-24
7. Various control..........................................................................................04-25
7-1. Auto restart...................................................................................................................04-25
7-2. MANUAL AUTO operation............................................................................................04-25
7-3. Forced cooling operation ..............................................................................................04-26
7-4. 10 °C HEAT operation..................................................................................................04-26
7-5. ECONOMY operation ...................................................................................................04-26
7-6. POWERFUL operation ................................................................................................04-27
7-7. Compressor preheating ................................................................................................04-27
7-8. Electronic expansion valve control ...............................................................................04-27
7-9. Prevention to restart for 3 minutes (3 minutes st) .........................................................04-28
7-10. 4-way valve control.....................................................................................................04-28
7-11. Outdoor unit low noise operation ................................................................................04-28
8. Various protections...................................................................................04-29
8-1. Discharge gas temperature over-rise prevention control ..............................................04-29
8-2. Anti-freezing control (cooling and dry mode) ................................................................04-29
8-3. Current release control .................................................................................................04-30
8-4. Cooling pressure over-rise protection...........................................................................04-30
8-5. Low outdoor temperature protection.............................................................................04-30
8-6. High temperature and high pressure release control....................................................04-31