Service Manual

Table Of Contents
Check point 6. Check the remote controller
Hold down the THERMO SENSOR button until the thermo sensor icon is turned off.
→ If the space is still too warm, go to "Check point 7".
End
Check point 7. Check function settings
Using the table on the right adjust function 31. (Room Temperature Control for indoor unit sensor)
NOTE: For details of function setting number 31, refer to "Function settings " in Chapter 5. FIELD
WORKING on page 05-1.
End
Check point 8. Check the remote controller display
Is the "Thermo Sensor Icon" displayed on the screen?
→ If no, go to "Check point 8-1".
Check point 9. Check the function Setting
Is function 48 (Room temperature sensor switching) set to 01?
→ If no, go to "Check point 9-1".
3-7. Too warm - (03-44) - 3. Troubleshooting without error code
TROUBLESHOOTING
TROUBLESHOOTING