ASUG12LZBS Operation Manual

En-9
The frequency of the cleaning is as shown in the following table.
What to do Frequency
Cleaning indoor unit body When you notice
Cleaning air lter Every 2 weeks
Cleaning Ion deodorization lter Every 3 months
Replacing Apple-catechin lter
(Model name: UTR-FA16)
Replacing Ion deodorization lter
(Model name: UTR-FA16-2)
Every 3 years
* The air cleaning lters are sold separately. When you replace them,
contact the store of purchase.
Cleaning indoor unit body
NOTES:
Do not use water hotter than 104 °F (40 °C).
Do not use scouring cleanser, volatile solvents such as benzene or
thinner.
1. Wipe the indoor unit body gently with a soft cloth moisten
with warm water.
2. Wipe the indoor unit body gently with a dry and soft cloth.
Cleaningairlter
1. Open the intake grille until it snaps.
2. Remove the air lters.
Lift up the air lters' handle, disconnect the two lower tabs, and pull
out.
Air lter handle
Hooks (2 places)
3. Remove the dust in either of the following ways.
Cleaning with vacuum cleaner.
Washing with mild detergent and warm water. After washing, dry the
air lters thoroughly in shade.
4. Replace the air lters.
Align the sides of the air lter with the panel, and push in fully.
Make sure to the two lower tabs are returned to their holes in the
indoor unit properly.
5. Close the intake grille.
Press 4 places on the intake grille to close it completely.
NOTE: If dirt accumulates on the air lter, airow will be reduced,
operating e󰀩ciency will lower, and the noise will increase.
CleaningIondeodorizationlterand
ReplacingApple-catechinlter
1. Remove the air lters. Refer to steps 1 ~ 2
of "Cleaning air
lter".
2. Remove the air cleaning lters from the air cleaning lter
holder.
Air cleaning lter
Air cleaning lter holder
3. Flush the Ion deodorization lter (light blue) with high-
pressure hot water until the surface of the lters are covered
with water.
4. Wash the Ion deodorization lter with diluent neutral
detergent.
Do not ream or rub, otherwise the deodorizing e󰀨ect may decrease.
5. Rinse the Ion deodorization lter with water ow.
6. Dry the Ion deodorization lter in shade.
7. Remove the Apple-catechin lter (light green) from the air
cleaning lter holder.
8. Set the new or washed air cleaning lters into the air
cleaning lter holders.
NOTE: Use the Apple-catechin lter as soon as possible after opening
the package. The air cleaning e󰀨ect decreases when the lters
are left in the opened package.
9. Install the air cleaning lter holders to the air lters.
Engage the 4 hooks at the rear of the air cleaning lter holder with
the latch at both ends of the air lter.
Hook (4 places at the rear)
Latch (4 places)
NOTE: Take care that the air cleaning lter does not project beyond
the holder.
10. Replace the air lters and close the intake grille. Refer to
steps 4 ~ 5 of "Cleaning air lter".
ReplacingIondeodorizationlter
1. Remove the air lters. Refer to steps 1 ~ 2
of "Cleaning air
lter".
2. Remove the Ion deodorization lter (light blue) from the air
cleaning lter holder.
3. Install the new Ion deodorizing lter.
9387602210_OM.indb 99387602210_OM.indb 9 25/02/2021 11:23:0125/02/2021 11:23:01