Halcyon Brochure

50 51
MULTI-ZONE MINI-SPLITS
7, 9, 12, 18,000 BTUh COMPACT CASSETTES
EASY INSTALLATION
Fits into a standard ceiling tile. Dimensions of outer grille are
27-9/16” x 27-9/16” and may overlap adjacent tiles.
2-STAGE TURBO FAN
Air distribution is evenly spread across the heat exchanger
by the 2 stage turbo fan which produces two separate airflow
streams.
22.5”
22.5”
Heat exchange
efficiency:
Increased 20%
1-stage
2-stage
Fresh Air Kit**
UTZ-VXAA
Mixes room air then passes through the
heat exchanger.
HFI AUU7RLF, AUU9RLF, AUU12RLF, AUU18RLF
1 Applies when properly registered AND installed by a Fujitsu Elite Contractor in residence. See full warranty for details.
2 Available only with optional wireless remote control.
3 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for
systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have
similar heating and cooling requirements and have similar temperature set points, auto changeover will work.
4 Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at .2”W.C. or
90 CFM at .4”W.C. For fan static pressure requirements, see installation manual. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the
height of the indoor unit.
5 Available only with optional Interface kit. Operation monitoring and On/Off control only.
6 Available only when used with Flex Zone AOU48RLXFZ1 outdoor unit.
1
Economy
Minimum Heat
2
Changeover
Auto
3
Adjust
Up/Down
Restart
Dry
Fresh
4
Quiet Mode
24 Hour
2
Sleep
2
Weekly
Cold
Ceiling
Sensor
I/O
3rd Party
5
Pump
16
Daisy
164+ ft
Piping
6
AUU7RLF AUU9RLF AUU12RLF AUU18RLF
Performance
Nominal Cooling BTUh 7,000 9,000 12,000 18,000
Nominal Heating BTUh 8,100 10,200 13,500 20,000
Fan
Air Circulation: Hi CFM (m3/h)
318 (540)
Clg or Htg
318 (540)
Clg or Htg
359 (610)
Clg or Htg
441 (750) Clg
471 (800) Htg
Medium CFM (m3/h)
288 (490)
Clg or Htg
288 (490)
Clg or Htg
312 (530)
Clg or Htg
359 (610) Clg
418 (710) Htg
Low CFM (m3/h)
259 (440)
Clg or Htg
259 (440)
Clg or Htg
277 (470)
Clg or Htg
306 (520) Clg
353 (600) Htg
Quiet CFM (m3/h)
230 (390)
Clg or Htg
230 (390)
Clg or Htg
241 (410)
Clg or Htg
241 (410) Clg
265 (450) Htg
Fan Speed Stage 4+auto 4+auto 4+auto 4+auto
Sound
Indoor Sound Level (Clg/Htg): Hi dB(A) 33/34 33/34 37/37 42/44
Medium dB(A) 31/32 31/32 33/33 37/40
Low dB(A) 29/29 29/29 31/31 33/37
Quiet dB(A) 27/27 27/27 28/28 29/30
Electrical
Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Current Rated: Cooling Amps 0.15 0.15 0.19 0.30
Current Rated: Heating Amps 0.15 0.15 0.19 0.30
Power Use Rated/Max: Cooling (kw) 18 18 23 39
Power Use Rated/Max: Heating (kw) 18 18 23 39
Size & Weight
Net Weight lbs. (kg) 33 (15) 33 (15) 33 (15) 33 (15)
Dimensions: Height
Inch 9-11/16 9-11/16 9-11/16 9-11/16
mm 245 245 245 245
Width
Inch 22-7/16 22-7/16 22-7/16 22-7/16
mm 570 570 570 570
Depth
Inch 22-7/16 22-7/16 22-7/16 22-7/16
mm 570 570 570 570
Refrigerant R410A R410A R410A R410A
Additional Data
Air Direction: Vertical Automatic Automatic Automatic Automatic
Air Filter Washable Washable Washable Washable
Front Grille UTG-CCGF* UTG-CCGF* UTG-CCGF* UTG-CCGF*
Grille Dim: Height
Inch (mm) 1-15/16 (49) 1-15/16 (49) 1-15/16 (49) 1-15/16 (49)
Width
Inch (mm) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700)
Depth Inch (mm) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700)
Lineset Size Inch
suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4
* Compact Cassette Grille UTG-CCGF sold separately. Must order one with each compact cassette.