Submittal

Submittal Data:18RLXFW1 18,000 BTU Wall Mount
Inverter Driven Heat Pump
Job Name:______________________________ Date:_______________________________
Location:_______________________________ Approval:____________________________
Engineer:_______________________________ Construction:_________________________
Submitted to:____________________________ Unit #:______________________________
Submitted by:___________________________ Drawing #:___________________________
Reference:______________________________
Model Information
Condenser……………………..........………………..……..….… AOU18RLXFW1
Evaporator……………….…………………...……………....………... ASU18RLF
Electrical …………………………………..……......... 208/230 V AC 1ph-60HZ
Available Voltage Range………………………..………….… 187 - 253 V +/- 10%
Max Fuse Size…….…………………………………........................................ 20 A
Max Operating Current (Evaporator)………………..................………….… 14.5 A
Starting Current (Condenser)……….…….…………………………............... 8.0 A
Input Power
Cooling…………………………………………………….……..……..…. 1.35 kW
Heating……………………………………………………………....….…. 1.75 kW
Running Current
Cooling………………………………………..……………………………… 6.2 A
Heating………………………………………………………………..……..... 7.8 A
Capacity
Nominal Cooling………………….…………...……………………... 18,000 Btu/h
Min-Max Cooling…………………...………………...…..…. 7,000 – 23,000 Btu/h
Nominal Heating……………………………..………...………........... 21,600 Btu/h
Min-Max Heating………………………………..…............... 7,000 – 29,000 Btu/h
Compressor…………………………………….…............................… Rotary x1
Motor Output…………………………………………..……….....…….… 2,100 W
Refrigerant…………………………………………………………………… R410a
Charge……..………………………………..………………..……4 lbs. 10.1 oz.
Oil…………………………………………………………......…….… POE (RB68)
Fan Motor
Type: DC (condenser)………….………………….……….....……...... Propeller x1
Type: DC (evaporator)……………………………...…………… Cross flow fan x1
Motor Output (condenser)…………………………….……..………………. 100 W
Motor Output (evaporator)………………….............………………………… 53 W
Heat Exchanger
Condenser
(H x W x D) in. (mm)..….........……… 31-7/16 x 35-7/16 x 1-7/16 (798x900x36.4)
Fin Pitch……………………………………...…..……….……………...….. 20 FPI
Rows x Stages……………………………….…....………...……………..…. 2 x 38
Pipe Type (Material)………....………………...…..…..… Grooved H-Pin (Copper)
Fin Type (Material)…………..……………..………..........Aluminum (Blue Fin)
Note: Specifications are based on the following conditions.
Cooling: Indoor temperature of 80°F (26.7°C) DB/67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C) WB.
Heating: Indoor temperature of 70°F (21.11°C) DB/59°F (15.°C) WB, and outdoor temperature of 47°F (8.33°C) DB/43°F (6.11°C) WB.
Pipe length: 24ft. 7in. (7.5m), Height difference: 0ft. (0m) (Outdoor unit indoor unit)
Operation Temperature Range
Cooling…………...………….……………………… -5°F to 115°F (-20°C - 46°C)
Heating………………………………….………..…… -5°F to 75°F (-20°C - 24°C)
Efficiency
SEER……………………………………………………………………...…… 20.0
EER (cooling)……….……………………………………………………..…... 13.3
COP (heating)………………………………………………..…………........… 12.3
HSPF (heating)……………………………………………..……………..…… 10.4
Enclosure
Material
Evaporator………………………………….………..............…………. Polystyrene
Condenser…………………………………………….…… Painted galvanized steel
Color
Condenser…......………………………………..………. Beige (10 YR 7.5/1.0 NN)
Evaporator……………………………………………………………………. White
Sound Pressure Level
Condenser (max)…………….…………………………………….…...…. 50 dB(A)
Evaporator (max)……………………………………….………………… 44 dB(A)
Dimensions
H x W x D
Condenser in. (mm)…................................….. 32-3/4 x 35-3/8 x 13 (830x900x330)
Evaporator in. (mm).....................................….. 12-5/8 x 39-1/4 x 9 (320x998x228)
Connection Pipe
Liquid……………………...…..………………..…..……...… Ø3/8 in. (Ø9.52 mm)
Gas………………………..…......………………………….. Ø5/8 in. (Ø15.88 mm)
Method (Liquid/Gas)………………...…..........………..…...…………..…..… Flare
Max Length {(Pre-charge)}………..................…164 ft. (50 m) {(66 ft.) (20 m)}
Max Height Difference………………….…………………………….. 98 ft. (30 m)
Weight
Condenser…………………..…………………....………................ 135 lbs. (61 kg)
Evaporator………………..…….………….…..……......................... 31 lbs. (14 kg)
Accessories
UTY-RNNUM……...……............…...……………………… Wired remote control
UTY-RVNUM…...………………..............…………………. Wired remote control
UTY-RSNUM…………………….……………… Wired remote control (simple)
UTY-XWZXZ5………………………………………......…… Dry contact wire kit
Fujitsu General America, Inc.
353 Route 46 West
Fairfield, NJ 07004
Toll Free: 1-888-888-3424
Fax: (973) 836-0447
www.fujitsugeneral.com
General Features
1 of 2
Standard Warranty: 5 years parts, 7 years compressor. Applies to
systems purchased before June 1
st
2015*
Extended Warranty: 10 years parts, 10 years compressor. Systems
that have been installed on or after June 1
st
2015 by licensed
contractors and the online Product Registration has been submitted.**
Elite Contractor Extended Warranty: 12 years parts, 12 years
compressor. Systems that have been installed on or after June 1
st
2015
by contractors who have met requirements and have been approved
for elite contractor status plus, the online Product Registration has
been submitted. ***
Wired or wireless remote
Apple catechin filter
Ion deodorizing filter
Auto louver: up/down
Auto louver: 4-way
Low ambient cooling
Cold prevention
Sleep timer
24-hour timer
Blue fin coating
******

Summary of content (2 pages)