Operation Manual

En-2
OPERATING MANUAL
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing might have an effect on the
proper working or performance of the product.
2 Manual AUTO button
Use when you lost the remote controller or remote control malfunction occurs.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
less than 10 seconds.
AUTO
Press more than 10 seconds.
(Only for servicing.*)
Forced cooling
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop forced cooling, press this button or START/STOP button on
the remote controller.
3 Front panel
4 Vertical air ow direction louver
Each time you press SET button on the remote controller, the angle
of the vertical air ow direction louver moves as follows:
1
2
3
4
5
6
COOL or DRY mode HEAT mode
12
3
65
4
Do not adjust by hand.
The vertical air ow direction is set automatically as shown, in
accordance with the type of operation selected.
During Cooling/Dry mode : Horizontal ow 1
During Heating mode : Downward ow 5
During AUTO mode operation, for the rst a few minutes after
beginning operation, air ow will be horizontal 1; the air direction
cannot be adjusted during this period.
• Direction 1
2
Only the direction of the Air ow Direction Louver changes; the
direction of the Power Diffuser does not change.
The air ow direction setting will temporarily become 1 when the
temperature of the air ow is low at the start of the Heating mode.
After beginning of AUTO/HEAT mode operated and automatic
defrosting operation time, the air ow will be horizontal 1.
However, the Air ow Direction cannot be adjusted at beginning AUTO operation mode.
5 Power diffuser
In conjunction with movement of the vertical air ow direction louver,
the angle of the power diffuser moves as follows:
Vertical air ow
direction louver
Power diffuser
In SWING operation, power diffuser does not move.
6 Drain hose
7 Remote control signal receiver
CAUTION
For appropriate signal transmission between remote controller and the
indoor unit, keep the signal receiver away from following items
:
- Direct sunlight or other strong light
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as inverter type
ones, the signal may not be transmitted properly. In such a case,
consult the store that you purchased the product
.
8 ECONOMY indicator (green)
ECONOMY indicator lamp lights when ECONOMY operation and
MINIMUM HEAT operation are operating.
9 TIMER indicator (orange)
If the TIMER indicator lamp ashes when the timer is operating, it
indicates that a fault has occurred with the timer setting (Auto Restart).
0 OPERATION indicator (green)
A Horizontal air ow direction louvers
Each time you press SET button on the remote controller, the angle
of the horizontal air ow direction louver moves as follows:
1 2 3 4 5
1
2
3
4
5
See page 6
B Air lter
Easy-to-care air lters resist mildew growth.
See page 7
C Air cleaning lters
Purify or deodorize the air, and provide fresh air ow.
Indoor unit accessories
Remote controller
Batteries Air cleaning lters Filter holders
Remote controller holder
Tapping screws
(M3 × 12 mm)
WARNING
Take care to prevent infants and young children from accidentally swallowing the batteries.
Remote controller holder installation
321
Screws
Slide up
Pull out
Insert
Press in
Indoor Unit Overview and Operations